The NeuroMET project: Metrology and innovation for early diagnosis and accurate stratification of patients with neurodegenerative diseases

Authors:

Abstract
Background: The NeuroMET project aims are to develop: 1) a “NeuroMET memory metric” metrologically validated with clinical laboratory data that will be implemented into a app for delivery of cognitive tests 2) 7T magnetic resonance imaging and spectroscopy protocols and measurement uncertainty frameworks to be implemented into clinic and applied to larger studies; 3) reference measurement procedures and liquid chromatography based methods for t‐tau; p‐tau; α‐synuclein, NF‐L to underpin standardisation initiatives; 4) new clinical methods for quantification of synucleins and differentiation of synucleopathies for subsequent validation with support from the metrological infrastructure; and 5) construct specification equations to serve as reference for memory task difficulty and person memory abilityMethod: Multiple approaches: LC‐MS and GC‐MS from different manufactures; 7 and 3 Tesla MRI and MRS (Siemens); RT‐QUIC; immunoassays (Simoa, MSD and Eurimmune); Rasch Measurement Theory analysis and principal component regression. All data are acquired for healthy controls, subjective cognitive decline, mild cognitive impairment and Alzheimer’s disease patients recruited at Charitè.Result: 1) The most promising memory test items from legacy cognitive assessments data (focussing on blocks, numbers and word lists) from the NeuroMET patient cohort were selected to be used for the development of the NeuroMET Memory Metric. Construct specification equations were developed to serve as reference for memory task difficulty and person memory. 2) 7 T MRI and MRS protocols were developed. Those are applied to the project cohort and a framework for the definition and improvement of measurement uncertainty is designed. 3) A t‐tau primary calibrator characterization was finalized and the material shared with the IFCC‐CSF WG to be used for a round robin study. 4) A α‐synuclein reference measurement procedure was finalized and a hydrogen deuterium exchange mass spectrometry method developed to monitor the stability of the protein in different solvents and storage conditions. This methods will underpin the development of a liquid chromatography mass spectrometry method and a RT_QUIC method for synucleopathiesConclusion: Multidisciplinary reference methods and frameworks for the definition of measurement uncertainty to be applied to facilitate uptake of new technology, to underpin the definition of clinical thresholds and ultimately to enable early diagnosis and patient stratification