MQMilena Quaglia

Milena Quaglia

*This is an algorithmically generated author record based on publicly available information.

Milena Quaglia has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Neurofilament Light Chain ELISA Validated in Patients with Alzheimer’s Disease, Frontotemporal Dementia, and Subjective Cognitive Decline, and the Evaluation of Candidate Proteins for Immunoassay Calibration

    by Shreyasee Das, Nele Dewit, Dirk Jacobs, Yolande A. L. Pijnenburg, Sjors G. J. G. In ‘T Veld, Salomé Coppens, Milena Quaglia, Christophe Hirtz, Charlotte E. Teunissen, Eugeen Vanmechelen

    Neurofilament light chain (Nf-L) is a well-known biomarker for axonal damage; however, the corresponding circulating Nf-L analyte in cerebrospinal fluid (CSF) is poorly characterized. We therefore isolated new monoclonal antibodies against synthetic peptides, and these monoclonals were characterized for their specificity on brain-specific intermediate filament proteins. Two highly specific antibodies, ADx206 and ADx209, were analytically validated for CSF applications according to well-established criteria. Interestingly, using three different sources of purified Nf-L proteins, a significant impact on interpolated concentrations was observed. With a lower limit of analytical sensitivity of 100 pg/mL using bovine Nf-L as the calibrator, we were able to quantify the Nf-L analyte in each sample, and these Nf-L concentrations were highly correlated to the Uman diagnostics assay (Spearman rho = 0.97, p < 0.001). In the clinical diagnostic groups, the new Nf-L ELISA could discriminate patients with Alzheimer’s disease (AD, n = 20) from those with frontotemporal lobe dementia (FTD, n = 20) and control samples with subjective cognitive decline (SCD, n = 20). Henceforth, this novel Nf-L ELISA with well-defined specificity and epitopes can be used to enhance our understanding of harmonizing the use of Nf-L as a clinically relevant marker for neurodegeneration in CSF.


  • Open Access

    A Novel Neurofilament Light Chain ELISA Validated in Patients with Alzheimer’s Disease, Frontotemporal Dementia, Subjective Cognitive Decline, and the Evaluation of Candidate Proteins for Immunoassay Calibration

    by Shreyasee Das, Nele Dewit, Dirk Jacobs, Yolande A.L. Pijnenburg, Sjors G.J.G. In 'T Veld, Salomé Coppens, Milena Quaglia, Christophe Hirtz, Charlotte E Teunissen, Eugeen J.M. Vanmechelen

    Neurofilament light chain (Nf-L) is a well-known biomarker for axonal damage, however the corresponding circulating Nf-L analyte in CSF is poorly characterized. We, therefore, isolated new monoclonal antibodies against synthetic peptides, and these monoclonals were characterized for their specificity on brain-specific intermediate filament proteins. Two highly specific antibodies, ADx206 and ADx209, were analytically validated for CSF applications according to well-established criteria. Interestingly, using three different sources of purified Nf-L proteins, a significant impact on interpolated concentrations was observed. With a lower limit of analytical sensitivity of 100 pg/ml using bovine Nf-L as the calibrator, we were able to quantify the Nf-L analyte in each sample and these Nf-L concentrations were highly correlated to the Uman diagnostics assay (Spearman rho= 0.97, P<0.001). In the clinical diagnostic groups, the new Nf-L ELISA could discriminate patients with Alzheimer’s disease (AD, n=20) from frontotemporal lobe dementia (FTD, n=20) and control samples with subjective cognitive decline (SCD, n=20). Henceforth, this novel Nf-L ELISA with well-defined specificity and epitopes can be used to enhance our understanding of harmonizing the use of Nf-L as a clinically relevant marker for neurodegeneration in CSF.


  • The NeuroMET project: Metrology and innovation for early diagnosis and accurate stratification of patients with neurodegenerative diseases

    by Milena Quaglia, Stefan Cano, Ariane Fillmer, Agnes Flöel, Chiara Giangrande, Laura Göschel, Sylvain Lehmann, Jeanette Melin, Charlotte E. Teunissen

    Background: The NeuroMET project aims are to develop: 1) a “NeuroMET memory metric” metrologically validated with clinical laboratory data that will be implemented into a app for delivery of cognitive tests 2) 7T magnetic resonance imaging and spectroscopy protocols and measurement uncertainty frameworks to be implemented into clinic and applied to larger studies; 3) reference measurement procedures and liquid chromatography based methods for t‐tau; p‐tau; α‐synuclein, NF‐L to underpin standardisation initiatives; 4) new clinical methods for quantification of synucleins and differentiation of synucleopathies for subsequent validation with support from the metrological infrastructure; and 5) construct specification equations to serve as reference for memory task difficulty and person memory abilityMethod: Multiple approaches: LC‐MS and GC‐MS from different manufactures; 7 and 3 Tesla MRI and MRS (Siemens); RT‐QUIC; immunoassays (Simoa, MSD and Eurimmune); Rasch Measurement Theory analysis and principal component regression. All data are acquired for healthy controls, subjective cognitive decline, mild cognitive impairment and Alzheimer’s disease patients recruited at Charitè.Result: 1) The most promising memory test items from legacy cognitive assessments data (focussing on blocks, numbers and word lists) from the NeuroMET patient cohort were selected to be used for the development of the NeuroMET Memory Metric. Construct specification equations were developed to serve as reference for memory task difficulty and person memory. 2) 7 T MRI and MRS protocols were developed. Those are applied to the project cohort and a framework for the definition and improvement of measurement uncertainty is designed. 3) A t‐tau primary calibrator characterization was finalized and the material shared with the IFCC‐CSF WG to be used for a round robin study. 4) A α‐synuclein reference measurement procedure was finalized and a hydrogen deuterium exchange mass spectrometry method developed to monitor the stability of the protein in different solvents and storage conditions. This methods will underpin the development of a liquid chromatography mass spectrometry method and a RT_QUIC method for synucleopathiesConclusion: Multidisciplinary reference methods and frameworks for the definition of measurement uncertainty to be applied to facilitate uptake of new technology, to underpin the definition of clinical thresholds and ultimately to enable early diagnosis and patient stratification


  • Open Access

    Reference Protocol to Assess Analytical Performance of Higher Order Structural Analysis Measurements: Results from an Interlaboratory Comparison

    by K. Groves, A. E. Ashcroft, A. Cryar, A. Sula, B. A. Wallace, B. B. Stocks, C. Burns, D. Cooper-Shepherd, E. De Lorenzi, E. Rodriguez, et al.

    Measurements of protein higher order structure (HOS) provide important information on stability, potency, efficacy, immunogenicity, and biosimilarity of biopharmaceuticals, with a significant number of techniques and methods available to perform these measurements. The comparison of the analytical performance of HOS methods and the standardization of the results is, however, not a trivial task, due to the lack of reference protocols and reference measurement procedures. Here, we developed a protocol to structurally alter and compare samples of somatropin, a recombinant biotherapeutic, and describe the results obtained by using a number of techniques, methods and in different laboratories. This, with the final aim to provide tools and generate a pool of data to compare and benchmark analytical platforms and define method sensitivity to structural changes. Changes in somatropin HOS, induced by the presence of zinc at increasing concentrations, were observed, both globally and at more localized resolution, across many of the methods utilized in this study and with different sensitivities, suggesting the suitability of the protocol to improve understanding of inter- and cross-platform measurement comparability and assess analytical performance as appropriate.


  • Development of a LC-MS method for the discrimination between trace level Prunus contaminants of spices

    by Sophie E. Inman, Kate Groves, Bryan McCullough, Milena Quaglia, Chris Hopley


  • Open Access

    A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide

    by Attila F. Torma, Kate Groves, Sabine Biesenbruch, Chris Mussell, Alan Reid, Steve Ellison, Rainer Cramer, Milena Quaglia

    Background: B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. Methods: B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15–150 fmol/g). Results: The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. Conclusions: The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.