MESOPIC AND DARK-ADAPTED TWO-COLOR FUNDUS-CONTROLLED PERIMETRY IN GEOGRAPHIC ATROPHY SECONDARY TO AGE-RELATED MACULAR DEGENERATION
- 1 January 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 40 (1) , 169-180
Abstract
Purpose: To investigate retinal sensitivity in the junctional zone of geographic atrophy (GA) secondary to age-related macular degeneration using patient-tailored perimetry grids for mesopic and dark-adapted two-color fundus-controlled perimetry. Methods: Twenty-five eyes with GA of 25 patients (prospective, natural-history Directional Spread in Geographic Atrophy study [DSGA; NCT02051998]) and 40 eyes of 40 normal subjects were included. Patient-tailored perimetry grids were generated using annotated fundus autofluorescence data. Customized software positioned test-points along iso-hulls surrounding the GA boundary at distances of 0.43°, 0.86°, 1.29°, 2.15°, and 3.01°. The grids were used for duplicate mesopic and dark-adapted two-color (cyan and red) fundus-controlled perimetry. Age-adjusted reference-data were obtained through regression analysis of normative data followed by spatial interpolation. Results: The mean sensitivity loss for mesopic testing decreased with the distance to GA (−10.3 dB [0.43°], −8.2 dB [0.86°], −7.1 dB [1.29°], −6.8 dB [2.15°], and −6.6 dB [3.01°]; P < 0.01). Dark-adapted cyan sensitivity loss exceeded dark-adapted red sensitivity loss for all iso-hulls (−14.8 vs. −11.7 dB, −13.5 vs. −10.1 dB, −12.8 vs. −9.1 dB, −11.6 vs. −8.2 dB, −10.7 vs. −8.0 dB; P < 0.01). Conclusion: Patient-tailored fundus-controlled perimetry grids allowed for testing of retinal function in the junctional zone of GA with high spatial resolution. A distinct decrease in mesopic sensitivity loss between 0.43° (125 µm) and 1.29° (375 µm) was observed that leveled off at more distant test-points. In proximity to the GA boundary, the results indicate that rod exceeded cone dysfunction.Keywords
This publication has 49 references indexed in Scilit:
- Macular Function in Macular Degenerations: Repeatability of Microperimetry as a Potential Outcome Measure forABCA4-Associated Retinopathy TrialsInvestigative Ophthalmology & Visual Science, 2012
- INNER SEGMENT–OUTER SEGMENT JUNCTIONAL LAYER INTEGRITY AND CORRESPONDING RETINAL SENSITIVITY IN DRY AND WET FORMS OF AGE-RELATED MACULAR DEGENERATIONRetina, 2011
- Changes in Retinal Sensitivity in Geographic Atrophy Progression as Measured by MicroperimetryInvestigative Ophthalmology & Visual Science, 2011
- Tracking Progression with Spectral-Domain Optical Coherence Tomography in Geographic Atrophy Caused by Age-Related Macular DegenerationInvestigative Ophthalmology & Visual Science, 2010
- Use of fundus perimetry (microperimetry) to quantify macular sensitivityProgress in Retinal and Eye Research, 2008
- READING NEWSPRINT BUT NOT HEADLINES: PITFALLS IN MEASURING VISUAL ACUITY AND COLOR VISION IN PATIENTS WITH BULLSEYE MACULOPATHY AND OTHER MACULAR SCOTOMASRETINAL Cases & Brief Reports, 2008
- WHAT YOU SEE IS NOT ALWAYS WHAT YOU GET IN ATROPHIC MACULAR DISEASERETINAL Cases & Brief Reports, 2008
- The Long-term Natural History of Geographic Atrophy from Age-Related Macular DegenerationOphthalmology, 2007
- Fundus Autofluorescence and Fundus Perimetry in the Junctional Zone of Geographic Atrophy in Patients with Age-Related Macular DegenerationInvestigative Ophthalmology & Visual Science, 2004
- Enlargement of atrophy and visual acuity loss in the geographic atrophy form of age-related macular degenerationOphthalmology, 1999