SSSteffen Md Schmitz-Valckenberg

Steffen Md Schmitz-Valckenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Steffen Md Schmitz-Valckenberg has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MESOPIC AND DARK-ADAPTED TWO-COLOR FUNDUS-CONTROLLED PERIMETRY IN GEOGRAPHIC ATROPHY SECONDARY TO AGE-RELATED MACULAR DEGENERATION

    by Maximilian Pfau, Philipp L. Müller, Leon von der Emde, Moritz Lindner, Philipp T. Möller, Monika Fleckenstein, Frank G. Md Holz, Steffen Md Schmitz-Valckenberg

    Purpose: To investigate retinal sensitivity in the junctional zone of geographic atrophy (GA) secondary to age-related macular degeneration using patient-tailored perimetry grids for mesopic and dark-adapted two-color fundus-controlled perimetry. Methods: Twenty-five eyes with GA of 25 patients (prospective, natural-history Directional Spread in Geographic Atrophy study [DSGA; NCT02051998]) and 40 eyes of 40 normal subjects were included. Patient-tailored perimetry grids were generated using annotated fundus autofluorescence data. Customized software positioned test-points along iso-hulls surrounding the GA boundary at distances of 0.43°, 0.86°, 1.29°, 2.15°, and 3.01°. The grids were used for duplicate mesopic and dark-adapted two-color (cyan and red) fundus-controlled perimetry. Age-adjusted reference-data were obtained through regression analysis of normative data followed by spatial interpolation. Results: The mean sensitivity loss for mesopic testing decreased with the distance to GA (−10.3 dB [0.43°], −8.2 dB [0.86°], −7.1 dB [1.29°], −6.8 dB [2.15°], and −6.6 dB [3.01°]; P < 0.01). Dark-adapted cyan sensitivity loss exceeded dark-adapted red sensitivity loss for all iso-hulls (−14.8 vs. −11.7 dB, −13.5 vs. −10.1 dB, −12.8 vs. −9.1 dB, −11.6 vs. −8.2 dB, −10.7 vs. −8.0 dB; P < 0.01). Conclusion: Patient-tailored fundus-controlled perimetry grids allowed for testing of retinal function in the junctional zone of GA with high spatial resolution. A distinct decrease in mesopic sensitivity loss between 0.43° (125 µm) and 1.29° (375 µm) was observed that leveled off at more distant test-points. In proximity to the GA boundary, the results indicate that rod exceeded cone dysfunction.


  • Open Access

    Mesopic and Dark-Adapted Two-Color Fundus-Controlled Perimetry in Choroidal Neovascularization Secondary to Age-Related Macular Degeneration

    by Leon von der Emde, Maximilian Pfau, Sarah Thiele, Philipp T. Möller, Ruth Hassenrik, Monika Fleckenstein, Frank G. Holz, Steffen Schmitz-Valckenberg

    Purpose: To determine the retest variability of mesopic and two-color dark-adapted (DA) fundus-controlled perimetry (FCP), to evaluate the predictive value of patient reliability indices, and to analyze the extent of impairment of rod- and cone function in neovascular age-related macular degeneration (nAMD). Methods: A total of 50 eyes of 50 patients with nAMD (mean age, 76.1 years) and 70 eyes of 70 age-similar normal subjects underwent multimodal imaging as well as mesopic and DA two-color perimetry using the S-MAIA device. A subset of patients (n = 28) underwent duplicate testing for retest reliability assessment. Mixed models were used for analysis of the hierarchical data. Results: In eyes with nAMD, the coefficient of repeatability was (mean ± standard deviation [SD]) 5.99 ± 1.55 dB for mesopic, 6.14 ± 2.19 dB for DA cyan, and 6.06 ± 1.09 dB for DA red testing. “Patient reliability indices” explained 55%, 54.2%, and 64.2% of the variance in retest variability. The mean sensitivity loss was greater for DA cyan compared to DA red testing (cyan-red differences [mean ± SD] −2.63 ± 3.87 dB, P < 0.001). Conclusions: The relatively greater degree of DA cyan versus DA red sensitivity loss indicates preferential rod vulnerability in nAMD, and qualifies rod function-based outcomes measures as potential sensitive and early markers of treatment response in nAMD. Translational Relevance: The S-MAIA allows reliable testing of mesopic, DA cyan, and DA red sensitivity in patients with nAMD. Patient reliability indices may serve as eligibility criteria for clinical trials to identify patients with adequate retest reliability.