PERFORMANCE OF THE VARSKIN 5 (v5.3) ELECTRON DOSIMETRY MODEL
Authors:
- 25 January 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 181 (2) , 111-119
Abstract
A new electron skin dosimetry model was developed for the VARSKIN 5 tissue dosimetry code. This model employs energy deposition kernels that provides for improved accuracy of energy deposition at the end of electron tracks. The Monte Carlo code EGSnrc was utilized to develop these energy deposition kernels such that scaling of electron energy loss is dependent on effective atomic number and density of the source material, electron range and conservation of energy. This work contrasts VARSKIN’s electron dosimetry model to several existing deterministic and Monte Carlo dosimetry tools to determine the efficacy of these improvements. Comparison results are given for a wide range of scenarios that extend beyond the typical use of VARSKIN, including mono-energetic electrons and a homogenous water medium. For planar and point sources in contact with the skin, VARSKIN produces results equated to other dosimetry methods within 10%. However, it appears that VARSKIN is unable to account accurately for electron energy loss with the introduction of a cover material or an air gap. The comparisons herein confirm that VARSKIN provides accurate electron dose calculations for skin-contamination scenarios.Keywords
Funding Information
- Nuclear Regulatory Commission (NRC-HQ-60-15-R-0017)
This publication has 9 references indexed in Scilit:
- Skin dose rate conversion factors after contamination with radiopharmaceuticals: influence of contamination area, epidermal thickness and percutaneous absorptionJournal of Radiological Protection, 2013
- VERIFICATION OF THE VARSKIN BETA SKIN DOSE CALCULATION COMPUTER CODEHealth Physics, 2008
- Skin Dose from Radionuclide Contamination on ClothingHealth Physics, 1997
- Absorbed Doses to Skin From Radionuclide Sources on the Body SurfaceHealth Physics, 1992
- ITS: the integrated TIGER series of electron/photon transport codes-Version 3.0IEEE Transactions on Nuclear Science, 1992
- Monte Carlo Calculation and Silicon Detector Measurement of the Hot Particle DoseHealth Physics, 1991
- Microcomputer Monte Carlo electron transport codes for beta skin dose calculationsIEEE Transactions on Nuclear Science, 1991
- Electron Dose-rate Conversion Factors for External Exposure of the Skin From Uniformly Deposited Activity on the Body SurfaceHealth Physics, 1987
- Calculation of Dose Rates for Skin Contamination by Beta RadiationRadiation Protection Dosimetry, 1986