Comparison of Physiological Motion Filters for In Vivo Cardiac ARFI
- 1 April 2011
- journal article
- research article
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 33 (2) , 89-108
Abstract
Acoustic radiation force impulse (ARFI) imaging is being utilized to investigate mechanical properties of cardiac tissue. The underlying physiological motion, however, presents a major challenge. This paper aims to investigate the effectiveness of various physiological motion filters using in vivo canine data with a simulated ARFI push pulse. Ideally, the motion filter will exactly model the physiological motion and, when subtracted from the total displacement, leave only the simulated ARFI displacement profile. We investigated three temporal quadratic motion filters: (1) interpolation, (2) extrapolation and (3) a weighted technique. Additionally, the various motion filters were compared when using 1-D versus 2-D autocorrelation methods to estimate motion. It was found that 2D-autocorrelation always produced better physiological motion estimates regardless of the type of filter used. The extrapolation filter gives the most accurate estimate of the physiological motion at times immediately after the ARFI push (0.1 ms) while a close-time interpolation filter using displacement estimates at times before full tissue recovery gives the most accurate estimates at latertimes after the ARFI push (0.7 ms). While improvements to the motion filter during atrial systole and the onset of ventricular systole are needed, the weighted, close-time interpolation and extrapolation motion filters all offer promising results for estimating cardiac physiological motion more accurately, while allowing faster ARFI frame rates than previous motion filters. This study demonstrates the ability to eliminate physiological motion in a clinically-feasible manner, opening the door for more extensive clinical experimentation.Keywords
This publication has 35 references indexed in Scilit:
- Diastolic heart failureHeart & Lung, 2008
- In Vivo Assessment of Myocardial Stiffness with Acoustic Radiation Force Impulse ImagingUltrasound in Medicine & Biology, 2007
- ECG-gated, Mechanical and Electromechanical Wave Imaging of Cardiovascular Tissues In VivoUltrasound in Medicine & Biology, 2007
- The Impact of Physiological Motion on Tissue Tracking During Radiation Force ImagingUltrasound in Medicine & Biology, 2007
- Assessment of Left Ventricular Viscoelastic Components Based on Ventricular Harmonic BehaviorCardiovascular Engineering, 2006
- Non-invasive assessment of ventricular force–frequency relations in the univentricular circulation by tissue Doppler echocardiography: a novel method of assessing myocardial performance in congenital heart diseaseHeart, 2005
- Cardiomyocyte Stiffness in Diastolic Heart FailureCirculation, 2005
- Diastolic Heart Failure — Abnormalities in Active Relaxation and Passive Stiffness of the Left VentricleNew England Journal of Medicine, 2004
- Tissue Doppler imaging: current and potential clinical applicationsHeart, 2000
- Real-Time Strain Rate Imaging of the Left Ventricle by UltrasoundJournal of the American Society of Echocardiography, 1998