BBBrett Byram

Brett Byram

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Brett Byram has a total of 130 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessing and improving deep domain alignment in ultrasound via simulation diversity

    by Ying-Chun Pan, Christopher M. Khan, Matthew Berger, John M. Bryant, Ryan J. Lefevre, Susan S. Eagle, Brett C. Byram

  • Open Access

    Towards Transcranial Functional Ultrasound Imaging Through the Adult Skull

    by Emelina P. Vienneau, Abbie E. Weeks, Ying-Chun Pan, Peggy M. Shema, Victoria L. Morgan, Brett C. Byram

    Functional ultrasound imaging (fUSI) is an emerging technology for assessing functional brain activity. To date, functional ultrasound without contrast agents has only been applied to human imaging during surgery with the skull removed or in neonates through a fontanel window. Here, we showcase a proof-of-concept study of contrast-free transcranial fUSI (tfUSI) through adult skulls. To achieve the high sensitivity and image quality required for tfUSI, we utilize several techniques including compound Barker coded excitation to boost signal-to-noise ratio, adaptive motion compensation and a head fixation device to minimize the effects of motion, and an eigen-based filtering approach to separate blood flow from tissue clutter. We assessed cerebrovascular reactivity induced by a breath hold by measuring cerebral blood volume with power Doppler imaging. We targeted the vasculature surrounding the midbrain in 13 healthy adult volunteers during a six minute task of alternating free breathing and breath holding periods. We showed that the power Doppler signal was correlated to the breath hold task ($\rho = 0.53 \pm 0.08$) and oxygen saturation ($\rho = 0.71 \pm 0.10$). Correlation coefficients were statistically significant for each subject (one-tailed $t$-test, $\alpha =0.01$). We also observed delayed vasodilation response in the power Doppler signal that reflected the expected delayed oxygen saturation drop from the breath hold. Delays to maximal signal were $47.69 \pm 23.7$ s for the first breath hold and $52.31 \pm 18.0$ s for the second breath hold. Our results demonstrate the utility of tfUSI for evaluating cerebrovascular reactivity and pave the way for further development to enable assessment of neural activation.


  • Open Access

    Expanding generalized contrast-to-noise ratio into a clinically relevant measure of lesion detectability by considering size and spatial resolution

    by Siegfried Schlunk, Brett C. Byram

    The clinical value of a medical ultrasound image is determined by the clinician viewing the image and depends on the clinical task being performed and their ability to make a correct assessment from the available image. However, in research and development, it is not feasible to have a clinician or team of clinicians assess every image. Instead, image quality metrics that correlate with clinician assessment are more efficient for large datasets or when quick iteration is needed. A common line of thinking is that clinical image quality should correlate with the ability to detect simple lesions. That is, a beamformer that reports more detectable lesions likely produces higher-quality images. This is why image quality metrics such as contrast-to-noise ratio (CNR) are often used. Though, in practice, image quality is a complex interaction between many aspects of the image and imaging system, this work focuses on the challenge of simple lesion detection and aims to create a robust metric for that task.


  • Methods for Enhancing the Robustness of the Generalized Contrast-to-Noise Ratio

    by Siegfried Schlunk, Brett C. Byram

    The generalized contrast-to-noise ratio (gCNR) is a new but increasingly popular metric for measuring lesion detectability due to its use of probability distribution functions (PDFs) that increase robustness against transformations and dynamic range alterations. The value of these kinds of metrics has become increasingly important as it becomes clear that traditional metrics can be arbitrarily boosted with advanced beamforming or the right kinds of post-processing. The gCNR works well for most cases, however, we will demonstrate that for some specific cases the implementation of gCNR using histograms requires careful consideration, as histograms can be poor estimates of PDFs when designed improperly. This is demonstrated with simulated lesions by altering the amount of data and the number of bins used in the calculation, as well as by introducing some extreme transformations that are represented poorly by uniformly-spaced histograms. In this work, the viability of a parametric gCNR implementation is tested, more robust methods for implementing histograms are considered, and a new method for estimating gCNR using empirical cumulative distribution functions (eCDFs) is shown. The most consistent methods found were to use histograms on rank-ordered data or histograms with variable bin widths, or to use empirical CDFs to estimate the gCNR.


  • A Coded Excitation Framework for High SNR Transcranial Ultrasound Imaging

    by Emelina P. Vienneau, Brett C. Byram

    Robust transcranial ultrasound imaging is difficult due to poor image quality. In particular, low signal-to-noise ratio (SNR) limits sensitivity to blood flow and has hindered clinical translation of transcranial functional ultrasound neuroimaging thus far. In this work, we present a coded excitation framework to increase SNR in transcranial ultrasound without negatively impacting frame rate or image quality. We applied this coded excitation framework in phantom imaging and showed SNR gains as large as 24.78 dB and signal-to-clutter ratio gains as high as 10.66 dB with a 65 bit code. We also analyzed how imaging sequence parameters can impact image quality and showed how coded excitation sequences can be designed to maximize image quality for a given application. In particular, we show that considering the number of active transmit elements and the transmit voltage is critical for coded excitation with long codes. Finally, we applied our coded excitation technique in transcranial imaging of ten adult subjects and showed an average SNR gain of 17.91 ± 0.96 dB without a significant increase in clutter using a 65 bit code. We also performed transcranial power Doppler imaging in three adult subjects and showed contrast and contrast-to-noise ratio improvements of 27.32 ± 8.08 dB and 7.25 ± 1.61 dB, respectively with a 65 bit code. These results show that transcranial functional ultrasound neuroimaging may be possible using coded excitation.


  • Combining ADMIRE and MV to Improve Image Quality

    by Siegfried Schlunk, Brett Byram

    Aperture domain model image reconstruction (ADMIRE) is a frequency-domain, model-based beamformer, in part designed for removing reverberation and off-axis clutter. Minimum variance (MV) is alternatively designed to reduce off-axis interference and improve lateral resolution. MV is known to be less effective in high incoherent noise scenarios, and its performance in the presence of reverberation has not been evaluated. By implementing ADMIRE before MV, the benefits of both these beamformers can be achieved. In this article, the assumptions of MV are discussed, specifically their relationship to reverberation clutter. The use of ADMIRE as a preprocessing step to suppress noise from simulations with linear scanning and in vivo curvilinear kidney data is demonstrated, and both narrowband and broadband implementations of MV are applied. With optimal parameters, ADMIRE + MV demonstrated sizing improvements over MV alone by an average of 52.1% in 0-dB signal-to-clutter ratio reverberation cyst simulations and 14.5% in vivo while improving the contrast ratio compared to ADMIRE alone by an average of 15.1% in simulations and 14.0% in vivo . ADMIRE + MV demonstrated a consistent improvement compared to DAS, MV, and ADMIRE both in terms of sizing and contrast ratio.


  • Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging

    by Emelina P. Vienneau, Kathryn A. Ozgun, Brett C. Byram

    Thermal noise and acoustic clutter signals degrade ultrasonic image quality and contribute to unreliable clinical assessment. When both noise and clutter are prevalent, it is difficult to determine which one is a more significant contributor to image degradation because there is no way to separately measure their contributions in vivo . Efforts to improve image quality often rely on an understanding of the type of image degradation at play. To address this, we derived and validated a method to quantify the individual contributions of thermal noise and acoustic clutter to image degradation by leveraging spatial and temporal coherence characteristics. Using Field II simulations, we validated the assumptions of our method, explored strategies for robust implementation, and investigated its accuracy and dynamic range. We further proposed a novel robust approach for estimating spatial lag-one coherence. Using this robust approach, we determined that our method can estimate the signal-to-thermal noise ratio (SNR) and signal-to-clutter ratio (SCR) with high accuracy between SNR levels of −30 to 40 dB and SCR levels of −20 to 15 dB. We further explored imaging parameter requirements with our Field II simulations and determined that SNR and SCR can be estimated accurately with as few as two frames and sixteen channels. Finally, we demonstrate in vivo feasibility in brain imaging and liver imaging, showing that it is possible to overcome the constraints of in vivo motion using high-frame rate M-Mode imaging.


  • Training Deep Network Ultrasound Beamformers With Unlabeled In Vivo Data

    by Jaime Tierney, Adam Luchies, Christopher Khan, Jennifer Baker, Daniel Brown, Brett Byram, Matthew Berger

    Conventional delay-and-sum (DAS) beamforming is highly efficient but also suffers from various sources of image degradation. Several adaptive beamformers have been proposed to address this problem, including more recently proposed deep learning methods. With deep learning, adaptive beamforming is typically framed as a regression problem, where clean ground-truth physical information is used for training. Because it is difficult to know ground truth information in vivo , training data are usually simulated. However, deep networks trained on simulations can produce suboptimal in vivo image quality because of a domain shift between simulated and in vivo data. In this work, we propose a novel domain adaptation (DA) scheme to correct for domain shift by incorporating unlabeled in vivo data during training. Unlike classification tasks for which both input domains map to the same target domain, a challenge in our regression-based beamforming scenario is that domain shift exists in both the input and target data. To solve this problem, we leverage cycle-consistent generative adversarial networks to map between simulated and in vivo data in both the input and ground truth target domains. Additionally, to account for separate as well as shared features between simulations and in vivo data, we use augmented feature mapping to train domain-specific beamformers. Using various types of training data, we explore the limitations and underlying functionality of the proposed DA approach. Additionally, we compare our proposed approach to several other adaptive beamformers. Using the DA DNN beamformer, consistent in vivo image quality improvements are achieved compared to established techniques.


  • Multidimensional Clutter Filtering of Aperture Domain Data for Improved Blood Flow Sensitivity

    by Kathryn A. Ozgun, Brett C. Byram

    Singular value decomposition (SVD) is a valuable factorization technique used in clutter rejection filtering for power Doppler imaging. Conventionally, SVD is applied to a Casorati matrix of radio frequency data, which enables filtering based on spatial or temporal characteristics. In this article, we propose a clutter filtering method that uses a higher order SVD (HOSVD) applied to a tensor of aperture data, e.g., delayed channel data. We discuss temporal, spatial, and aperture domain features that can be leveraged in filtering and demonstrate that this multidimensional approach improves sensitivity toward blood flow. Further, we show that HOSVD remains more robust to short ensemble lengths than conventional SVD filtering. Validation of this technique is shown using Field II simulations and in vivo data.


  • Evaluating Input Domain and Model Selection for Deep Network Ultrasound Beamforming

    by Jaime Tierney, Adam Luchies, Matthew Berger, Brett Byram

    Improving ultrasound B-mode image quality remains an important area of research. Recently, there has been increased interest in using deep neural networks (DNNs) to perform beamforming to improve image quality more efficiently. Several approaches have been proposed that use different representations of channel data for network processing, including a frequency-domain approach that we previously developed. We previously assumed that the frequency domain would be more robust to varying pulse shapes. However, frequency- and time-domain implementations have not been directly compared. In addition, because our approach operates on aperture domain data as an intermediate beamforming step, a discrepancy often exists between network performance and image quality on fully reconstructed images, making model selection challenging. Here, we perform a systematic comparison of frequency- and time-domain implementations. In addition, we propose a contrast-to-noise ratio (CNR)-based regularization to address previous challenges with model selection. Training channel data were generated from simulated anechoic cysts. Test channel data were generated from simulated anechoic cysts with and without varied pulse shapes, in addition to physical phantom and in vivo data. We demonstrate that simplified time-domain implementations are more robust than we previously assumed, especially when using phase preserving data representations. Specifically, 0.39- and 0.36-dB median improvements in in vivo CNR compared to DAS were achieved with frequency- and time-domain implementations, respectively. We also demonstrate that CNR regularization improves the correlation between training validation loss and simulated CNR by 0.83 and between simulated and in vivo CNR by 0.35 compared to DNNs trained without CNR regularization.