96-Sample Parallel BioSPME-DART-MS Platform for Rapid Screening of Fentanyl and its Analogues in Biofluids
- 8 October 2026
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 31703-31711
Abstract
Solid-phase microextraction (SPME) with biocompatible coating material is highly compatible with ambient mass spectrometry (AMS), such as direct analysis in real time (DART), for improving sensitivity and reducing matrix effects. However, the practical throughput of SPME−DART-MS remains limited by the mismatch between parallel sample preparation and device-to-source transfer. Here, we introduce a 96-sample parallel BioSPME-DART-MS platform that integrates automated SPME extraction, 96-channel liquid transfer, and a matched 96-position DART mesh interface. This design enables 96 biological samples to be processed in a plate-based format, greatly improves workflow transferability. Thin HLB/PAN-coated SPME blades were used to provide bio-compatible extraction and cleanup from whole blood, plasma, and urine. After desorption in 200 μL of solvent, only 5 μL of the extract was transferred to the DART mesh for rapid MS/MS screening, while the remaining solution was retained for sequential LC−MS/MS confirmation without additional sample preparation. The system enabling an average analysis time of approximately 40 s per sample. Using six fentanyl and its analogues as model analytes, the BioSPME-DART-MS method achieved good sensitivity across the three biofluids, with limits of detection of 0.10−0.50 ng mL−1 in whole blood, 0.03−0.20 ng mL−1 in plasma, and 0.01−0.20 ng mL−1 in urine. In addition, a comparative study of absolute matrix effects revealed that chromatography-free DART-MS and blade spray-MS remained susceptible to ion suppression, whereas LC−ESI-MS showed negligible matrix effects. This platform establishes a high-throughput, two-tier SPME−MS workflow that combines rapid ambient MS screening with chromatography-based confirmation.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 33 references indexed in Scilit:
- Building a Bridge Between Ambient MS and LC‐MS by Non‐Exhaustive MicrodesorptionAngewandte Chemie, 2025
- Rapid quantitative screening of 15 synthetic cannabinoids in urine using direct analysis in real time tandem mass spectrometry: Screening method validation and cross-correlation study with liquid chromatography tandem mass spectrometryGreen Analytical Chemistry, 2025
- High throughput and automated solid-phase microextraction and determination by liquid chromatography-mass spectrometry for the analysis of mycotoxins in beerFood Chemistry, 2023
- Operation of the anti‐doping laboratory for the Beijing 2022 Olympic and Paralympic Winter GamesDrug Testing and Analysis, 2022
- Doping control analyses during the Tokyo 2020 Olympic and Paralympic GamesDrug Testing and Analysis, 2022
- Multiresidue pesticide quantitation in multiple fruit matrices via automated coated blade spray and liquid chromatography coupled to triple quadrupole mass spectrometryFood Chemistry, 2021
- A high‐throughput and broad‐spectrum screening method for analysing over 120 drugs in horse urine using liquid chromatography–high‐resolution mass spectrometryDrug Testing and Analysis, 2020
- Ionization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass SpectrometryJournal of the American Society for Mass Spectrometry, 2016
- Development of Coated Blade Spray Ionization Mass Spectrometry for the Quantitation of Target Analytes Present in Complex MatricesAngewandte Chemie International Edition, 2014
- Recognition of beer brand based on multivariate analysis of volatile fingerprintJournal of Chromatography A, 2010