Wei Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Zhou has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Janusz Pawliszyn
University of Waterloo
18 shared publications Martyna N. Wieczorek
4 shared publications- Runshan Will Jiang
Department of Chemistry University of Waterloo Waterloo ON N2L 3G1 Canada
4 shared publications - Barbara Bojko
Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-089 Bydgoszcz, Poland
2 shared publications - Malvika Dutt
DiSPeA Department, University of Urbino Carlo Bo, Piazza Rinascimento, 6, Urbino 61029, Italy
2 shared publications Qizhen Lan
Department of Chemistry
2 shared publications
Latest Publications
- 8 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 31703-31711
96-Sample Parallel BioSPME-DART-MS Platform for Rapid Screening of Fentanyl and its Analogues in Biofluids
Solid-phase microextraction (SPME) with biocompatible coating material is highly compatible with ambient mass spectrometry (AMS), such as direct analysis in real time (DART), for improving sensitivity and reducing matrix effects. However, the practical throughput of SPME−DART-MS remains limited by the mismatch between parallel sample preparation and device-to-source transfer. Here, we introduce a 96-sample parallel BioSPME-DART-MS platform that integrates automated SPME extraction, 96-channel liquid transfer, and a matched 96-position DART mesh interface. This design enables 96 biological samples to be processed in a plate-based format, greatly improves workflow transferability. Thin HLB/PAN-coated SPME blades were used to provide bio-compatible extraction and cleanup from whole blood, plasma, and urine. After desorption in 200 μL of solvent, only 5 μL of the extract was transferred to the DART mesh for rapid MS/MS screening, while the remaining solution was retained for sequential LC−MS/MS confirmation without additional sample preparation. The system enabling an average analysis time of approximately 40 s per sample. Using six fentanyl and its analogues as model analytes, the BioSPME-DART-MS method achieved good sensitivity across the three biofluids, with limits of detection of 0.10−0.50 ng mL−1 in whole blood, 0.03−0.20 ng mL−1 in plasma, and 0.01−0.20 ng mL−1 in urine. In addition, a comparative study of absolute matrix effects revealed that chromatography-free DART-MS and blade spray-MS remained susceptible to ion suppression, whereas LC−ESI-MS showed negligible matrix effects. This platform establishes a high-throughput, two-tier SPME−MS workflow that combines rapid ambient MS screening with chromatography-based confirmation.
- 8 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 31703-31711
96-Sample Parallel BioSPME-DART-MS Platform for Rapid Screening of Fentanyl and its Analogues in Biofluids
Solid-phase microextraction (SPME) with biocompatible coating material is highly compatible with ambient mass spectrometry (AMS), such as direct analysis in real time (DART), for improving sensitivity and reducing matrix effects. However, the practical throughput of SPME−DART-MS remains limited by the mismatch between parallel sample preparation and device-to-source transfer. Here, we introduce a 96-sample parallel BioSPME-DART-MS platform that integrates automated SPME extraction, 96-channel liquid transfer, and a matched 96-position DART mesh interface. This design enables 96 biological samples to be processed in a plate-based format, greatly improves workflow transferability. Thin HLB/PAN-coated SPME blades were used to provide bio-compatible extraction and cleanup from whole blood, plasma, and urine. After desorption in 200 μL of solvent, only 5 μL of the extract was transferred to the DART mesh for rapid MS/MS screening, while the remaining solution was retained for sequential LC−MS/MS confirmation without additional sample preparation. The system enabling an average analysis time of approximately 40 s per sample. Using six fentanyl and its analogues as model analytes, the BioSPME-DART-MS method achieved good sensitivity across the three biofluids, with limits of detection of 0.10−0.50 ng mL−1 in whole blood, 0.03−0.20 ng mL−1 in plasma, and 0.01−0.20 ng mL−1 in urine. In addition, a comparative study of absolute matrix effects revealed that chromatography-free DART-MS and blade spray-MS remained susceptible to ion suppression, whereas LC−ESI-MS showed negligible matrix effects. This platform establishes a high-throughput, two-tier SPME−MS workflow that combines rapid ambient MS screening with chromatography-based confirmation.
- Open Access
- 11 May 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Non-exhaustive microextraction as a step towards more sustainable chemical analysis in the field and the clinic
- 11 May 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessNon-exhaustive microextraction as a step towards more sustainable chemical analysis in the field and the clinic
- Open Access
- 23 July 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1377, 344458
Coated blade spray-mass spectrometry for rapid screening: A tutorial
- 23 July 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1377, 344458
Open AccessCoated blade spray-mass spectrometry for rapid screening: A tutorial
- Open Access
- 22 July 2025
- Published by Wiley in Angewandte Chemie
- Vol. 137 (34)
Building a Bridge Between Ambient MS and LC‐MS by Non‐Exhaustive Microdesorption
Ambient mass spectrometry (AMS) offers rapid screening but faces challenges in analyzing complex samples due to high matrix effects. The absence of a separation step can also lead to false positives due to the isomers or isobars. In this study, a sequential analysis strategy which combines ambient MS and LC‐MS based on the non‐exhaustive microdesorption in solid‐phase microextraction (SPME) was developed for the first time. By combining coated blade spray (CBS)‐MS with LC‐MS, in the first step, a few microliters of solvent were used for non‐exhaustive desorption with high enrichment factor for rapid screening by CBS‐MS. For the suspicious samples, the remaining analytes on the SPME coating undergo exhaustive desorption, then followed by LC‐MS confirmation. The matrix‐compatible coating used in the SPME device significantly reduces matrix effects while enhancing sensitivity through analyte enrichment. This method is environmentally friendly, utilizing only a few microliters of organic solvents for screening. The approach was rigorously validated, both theoretically and experimentally, and successfully applied to anti‐doping testing, enabling detection of 53 prohibited substances in urine samples by integrating CBS‐MS with LC‐MS.
- 22 July 2025
- Published by Wiley in Angewandte Chemie
- Vol. 137 (34)
Open AccessBuilding a Bridge Between Ambient MS and LC‐MS by Non‐Exhaustive Microdesorption
Ambient mass spectrometry (AMS) offers rapid screening but faces challenges in analyzing complex samples due to high matrix effects. The absence of a separation step can also lead to false positives due to the isomers or isobars. In this study, a sequential analysis strategy which combines ambient MS and LC‐MS based on the non‐exhaustive microdesorption in solid‐phase microextraction (SPME) was developed for the first time. By combining coated blade spray (CBS)‐MS with LC‐MS, in the first step, a few microliters of solvent were used for non‐exhaustive desorption with high enrichment factor for rapid screening by CBS‐MS. For the suspicious samples, the remaining analytes on the SPME coating undergo exhaustive desorption, then followed by LC‐MS confirmation. The matrix‐compatible coating used in the SPME device significantly reduces matrix effects while enhancing sensitivity through analyte enrichment. This method is environmentally friendly, utilizing only a few microliters of organic solvents for screening. The approach was rigorously validated, both theoretically and experimentally, and successfully applied to anti‐doping testing, enabling detection of 53 prohibited substances in urine samples by integrating CBS‐MS with LC‐MS.
- Open Access
- 22 July 2025
- Published by Wiley in Advanced Science
- Vol. 13 (1) , e00396
Minimally Invasive Chemical Biopsy Needle with Self‐Wettable Extraction Phase For In Vivo Tissue Sampling During Medical Procedures
Chemical biopsy by solid‐phase microextraction (SPME) with sorbent‐coated fibers offers monitoring of biological processes in a significantly less invasive manner compared to conventional tissue biopsy. The developed device features a self‐protective design by using an acupuncture needle coated with biocompatible material only in a recessed section. The coating comprises micron‐sized naturally wettable sorbent particles embedded in a durable, biocompatible binder, ensuring broad analyte extraction coverage without the need for solvent activation. This design allows professionals in biochemical research and medical staff to use the device for in vivo monitoring of tissue concentrations of endogenous and/or exogenous substances without introducing activation solvent to the investigated system. The device is successfully used to sample anti‐cancer drugs in both animal models and human patients undergoing in vivo lung perfusion (IVLP) surgery, and then determine the drug concentration level by LC/MS. Finally, a proof‐of‐concept experiment using a microfluidic open interface (MOI) to directly desorb and introduce the extract analytes from the coating to MS detection is proposed for potential on‐site real‐time drug monitoring during the surgery.
- 22 July 2025
- Published by Wiley in Advanced Science
- Vol. 13 (1) , e00396
Open AccessMinimally Invasive Chemical Biopsy Needle with Self‐Wettable Extraction Phase For In Vivo Tissue Sampling During Medical Procedures
Chemical biopsy by solid‐phase microextraction (SPME) with sorbent‐coated fibers offers monitoring of biological processes in a significantly less invasive manner compared to conventional tissue biopsy. The developed device features a self‐protective design by using an acupuncture needle coated with biocompatible material only in a recessed section. The coating comprises micron‐sized naturally wettable sorbent particles embedded in a durable, biocompatible binder, ensuring broad analyte extraction coverage without the need for solvent activation. This design allows professionals in biochemical research and medical staff to use the device for in vivo monitoring of tissue concentrations of endogenous and/or exogenous substances without introducing activation solvent to the investigated system. The device is successfully used to sample anti‐cancer drugs in both animal models and human patients undergoing in vivo lung perfusion (IVLP) surgery, and then determine the drug concentration level by LC/MS. Finally, a proof‐of‐concept experiment using a microfluidic open interface (MOI) to directly desorb and introduce the extract analytes from the coating to MS detection is proposed for potential on‐site real‐time drug monitoring during the surgery.
- Open Access
- 22 July 2025
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 64 (34) , e202504080
Building a Bridge Between Ambient MS and LC‐MS by Non‐Exhaustive Microdesorption
Ambient mass spectrometry (AMS) offers rapid screening but faces challenges in analyzing complex samples due to high matrix effects. The absence of a separation step can also lead to false positives due to the isomers or isobars. In this study, a sequential analysis strategy which combines ambient MS and LC‐MS based on the non‐exhaustive microdesorption in solid‐phase microextraction (SPME) was developed for the first time. By combining coated blade spray (CBS)‐MS with LC‐MS, in the first step, a few microliters of solvent were used for non‐exhaustive desorption with high enrichment factor for rapid screening by CBS‐MS. For the suspicious samples, the remaining analytes on the SPME coating undergo exhaustive desorption, then followed by LC‐MS confirmation. The matrix‐compatible coating used in the SPME device significantly reduces matrix effects while enhancing sensitivity through analyte enrichment. This method is environmentally friendly, utilizing only a few microliters of organic solvents for screening. The approach was rigorously validated, both theoretically and experimentally, and successfully applied to anti‐doping testing, enabling detection of 53 prohibited substances in urine samples by integrating CBS‐MS with LC‐MS.
- 22 July 2025
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 64 (34) , e202504080
Open AccessBuilding a Bridge Between Ambient MS and LC‐MS by Non‐Exhaustive Microdesorption
Ambient mass spectrometry (AMS) offers rapid screening but faces challenges in analyzing complex samples due to high matrix effects. The absence of a separation step can also lead to false positives due to the isomers or isobars. In this study, a sequential analysis strategy which combines ambient MS and LC‐MS based on the non‐exhaustive microdesorption in solid‐phase microextraction (SPME) was developed for the first time. By combining coated blade spray (CBS)‐MS with LC‐MS, in the first step, a few microliters of solvent were used for non‐exhaustive desorption with high enrichment factor for rapid screening by CBS‐MS. For the suspicious samples, the remaining analytes on the SPME coating undergo exhaustive desorption, then followed by LC‐MS confirmation. The matrix‐compatible coating used in the SPME device significantly reduces matrix effects while enhancing sensitivity through analyte enrichment. This method is environmentally friendly, utilizing only a few microliters of organic solvents for screening. The approach was rigorously validated, both theoretically and experimentally, and successfully applied to anti‐doping testing, enabling detection of 53 prohibited substances in urine samples by integrating CBS‐MS with LC‐MS.
- 24 April 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (17) , 8756-8765
High-Throughput Screening of Polyfluoroalkyl Substances Using Solid-Phase Microextraction Coupled to Microfluidic Open Interface-Mass Spectrometry
Efficient and sustainable methods for large-scale PFAS monitoring are critical for addressing environmental and public health challenges. This work presents a high-throughput sample preparation system capable of processing up to 48 samples simultaneously using solid-phase microextraction (SPME) and was directly coupled with mass spectrometry (MS) via an automated microfluidic open interface (MOI), bypassing the need for chromatographic separation. The SPME-MOI-MS approach achieves sensitive detection of 18 PFAS in drinking water, with limits of detection (LODs) between 1 and 10 pg/mL, using just 1.5 mL of sample and an average analysis time of 2.8 min per sample. The SPME blades, employed to enhance sensitivity in place of standard SPME fibers, incorporate a matrix-compatible coating material that enables effective PFAS screening in water as well as complex matrices including blood, beer, and beef. In addition, significantly low recovery and reproducibility of nonpolar PFAS in water analysis have been found and studied, indicating that using a glass container and adding a small percentage of acetonitrile can address this issue.
- 24 April 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (17) , 8756-8765
High-Throughput Screening of Polyfluoroalkyl Substances Using Solid-Phase Microextraction Coupled to Microfluidic Open Interface-Mass Spectrometry
Efficient and sustainable methods for large-scale PFAS monitoring are critical for addressing environmental and public health challenges. This work presents a high-throughput sample preparation system capable of processing up to 48 samples simultaneously using solid-phase microextraction (SPME) and was directly coupled with mass spectrometry (MS) via an automated microfluidic open interface (MOI), bypassing the need for chromatographic separation. The SPME-MOI-MS approach achieves sensitive detection of 18 PFAS in drinking water, with limits of detection (LODs) between 1 and 10 pg/mL, using just 1.5 mL of sample and an average analysis time of 2.8 min per sample. The SPME blades, employed to enhance sensitivity in place of standard SPME fibers, incorporate a matrix-compatible coating material that enables effective PFAS screening in water as well as complex matrices including blood, beer, and beef. In addition, significantly low recovery and reproducibility of nonpolar PFAS in water analysis have been found and studied, indicating that using a glass container and adding a small percentage of acetonitrile can address this issue.
- 12 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (42) , 16520-16524
3D Printed Coated Blade Spray–Mass Spectrometry Devices
Coated blade spray-mass spectrometry (CBS-MS) has emerged as a powerful tool for the rapid screening of target compounds at trace levels in complex biological matrices. Despite its potential, the broader adoption of CBS-MS technology has been hindered by the lack of commercially available, user-friendly MS interfaces and extraction devices. In this work, we present comprehensive CBS-MS solutions developed using 3D printing, including a versatile MS interface and two extraction devices tailored to different analytical needs: one is compatible with LC vials for large-volume samples, while the other is optimized for single-drop blood analysis. The MS interface features a novel design that separates the immobilization station from the blade holder, significantly simplifying the operational workflow and minimizing the contamination risks and hazards associated with manual blade handling. The first extraction cartridge can process 48 samples simultaneously with an average sample preparation time of less than 20 s, while the second extraction device enables extraction from 8 single-drop blood samples via on-blade extraction. The developed devices were successfully tested for the rapid screening of seven drugs in both urine and single-drop blood samples, demonstrating a promising analytical performance. Additionally, potential contamination issues related to the use of 3D-printed materials as extraction phases were examined, emphasizing the importance of ensuring that 3D-printed materials do not leach contaminants into samples or solvents and contaminate the MS.
- 12 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (42) , 16520-16524
3D Printed Coated Blade Spray–Mass Spectrometry Devices
Coated blade spray-mass spectrometry (CBS-MS) has emerged as a powerful tool for the rapid screening of target compounds at trace levels in complex biological matrices. Despite its potential, the broader adoption of CBS-MS technology has been hindered by the lack of commercially available, user-friendly MS interfaces and extraction devices. In this work, we present comprehensive CBS-MS solutions developed using 3D printing, including a versatile MS interface and two extraction devices tailored to different analytical needs: one is compatible with LC vials for large-volume samples, while the other is optimized for single-drop blood analysis. The MS interface features a novel design that separates the immobilization station from the blade holder, significantly simplifying the operational workflow and minimizing the contamination risks and hazards associated with manual blade handling. The first extraction cartridge can process 48 samples simultaneously with an average sample preparation time of less than 20 s, while the second extraction device enables extraction from 8 single-drop blood samples via on-blade extraction. The developed devices were successfully tested for the rapid screening of seven drugs in both urine and single-drop blood samples, demonstrating a promising analytical performance. Additionally, potential contamination issues related to the use of 3D-printed materials as extraction phases were examined, emphasizing the importance of ensuring that 3D-printed materials do not leach contaminants into samples or solvents and contaminate the MS.
- Open Access
- 3 April 2024
- Published by Elsevier in Advances in Sample Preparation
- Vol. 10
Perspective on sample preparation fundamentals
- 3 April 2024
- Published by Elsevier in Advances in Sample Preparation
- Vol. 10
Open AccessPerspective on sample preparation fundamentals
- 27 March 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (14) , 5363-5367
Proteomic Analysis of Human Saliva via Solid-Phase Microextraction Coupled with Liquid Chromatography–Mass Spectrometry
Proteomics of human saliva samples was achieved for the first time via biocompatible solid-phase microextraction (bio-SPME) devices. Upon introduction of a porogen to a conventional C18 coating, porous C18/polyacrylonitrile (PAN) SPME blades were able to extract peptides up to 3.0 kDa and more peptides than commercial SPME blades. Following Trypsin digestion, salivary proteomic analysis was achieved via SPME-LC-MS/MS. Seven endogenous proteins were consistently identified in all saliva samples via bio-SPME. Taking advantage of this strategy, untargeted peptidomics was applied for the comparison of saliva samples between healthy and SARS-CoV-2 positive individuals. The results showed clear peptidomic differences between the viral and healthy saliva samples. This proof-of-concept study demonstrates the potential of bio-SPME-LC-MS/MS for peptidomics and proteomics in biomedical applications.
- 27 March 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (14) , 5363-5367
Proteomic Analysis of Human Saliva via Solid-Phase Microextraction Coupled with Liquid Chromatography–Mass Spectrometry
Proteomics of human saliva samples was achieved for the first time via biocompatible solid-phase microextraction (bio-SPME) devices. Upon introduction of a porogen to a conventional C18 coating, porous C18/polyacrylonitrile (PAN) SPME blades were able to extract peptides up to 3.0 kDa and more peptides than commercial SPME blades. Following Trypsin digestion, salivary proteomic analysis was achieved via SPME-LC-MS/MS. Seven endogenous proteins were consistently identified in all saliva samples via bio-SPME. Taking advantage of this strategy, untargeted peptidomics was applied for the comparison of saliva samples between healthy and SARS-CoV-2 positive individuals. The results showed clear peptidomic differences between the viral and healthy saliva samples. This proof-of-concept study demonstrates the potential of bio-SPME-LC-MS/MS for peptidomics and proteomics in biomedical applications.