Evaluation of a digestion procedure based on the use of diluted nitric acid solutions and H2O2for the multielement determination of whole milk powder and bovine liver by ICP-based techniques
- 22 November 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 29 (2) , 332-338
Abstract
Many efforts have been made in order to reduce the amount of reagents and waste produced in analytical laboratories. However, suitable digestion efficiency must be considered, and depending on the sample preparation procedure, incomplete digestion can result in severe matrix effects during analysis by spectrometric techniques such as ICP OES and ICP-MS. In the present work a procedure based on the use of H2O2 was developed in order to minimize the consumption of HNO3 without decreasing the efficiency of digestion. Although H2O2 has been used combined with HNO3 for sample digestion, its role is still not completely elucidated even as its action combined with O2 in pressurized systems. The performance obtained using H2O2 was similar to that observed when adding O2 to the reaction vessel, driving the better understanding of the role of H2O2 in closed digestion procedures. Digestion using H2O2 allowed the use of HNO3 solutions as diluted as 1 mol L−1 to digest sample masses of biological materials as high as 500 mg. The proposed procedure allowed a reduction of up to 14 and 9.3-fold in the HNO3 amount normally used in whole milk powder and bovine liver digestions, respectively, without decreasing the digestion efficiency. Calcium, Cu, Fe, K, Mg, Mn, Mo, Na, and Zn were determined by ICP OES, while Cd, Co, and Pb were determined by ICP-MS. Using diluted HNO3 solution low blank values were obtained resulting in relatively lower limits of detection and relative standard deviations. The accuracy was evaluated by using certified reference materials of milk powder and bovine liver (agreement was better than 95% to certified values for all evaluated analytes).Keywords
This publication has 29 references indexed in Scilit:
- A systematic study on the influence of carbon on the behavior of hard-to-ionize elements in inductively coupled plasma–mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2013
- Focused Microwave-Induced Combustion: A New Technique for Sample DigestionAnalytical Chemistry, 2010
- Carbon-related matrix effects in inductively coupled plasma atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Spectral and non-spectral interferences in the determination of selenium by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 2002
- Acid effects in inductively coupled plasma atomic emission spectrometry with different nebulizers operated at very low sample consumption ratesJournal of Analytical Atomic Spectrometry, 1998
- Investigation of decomposition products of microwave digestion of food samplesThe Analyst, 1995
- Determination of the residual carbon content by inductively coupled plasma atomic emission spectrometry after decomposition of biological samplesJournal of Analytical Atomic Spectrometry, 1992
- Some effects of low acid concentrations in inductively coupled plasma atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1990
- Residues from biological materials after pressure decomposition with nitric acidAnalytica Chimica Acta, 1989
- Residues from biological materials after pressure decomposition with nitric acidAnalytica Chimica Acta, 1989