Abstract
Goal: We introduce a novel approach to estimate cardiac output (CO) and central systolic blood pressure (cSBP) from noninvasive measurements of peripheral cuff-pressure and pulse wave velocity (PWV). Methods: The adjustment of a previously validated one-dimensional arterial tree model is achieved via an optimization process. In the optimization loop, compliance and resistance of the generic arterial tree model as well as aortic flow are adjusted so that simulated brachial systolic and diastolic pressures and cf-PWV converge towards the measured brachial systolic and diastolic pressures and cf-PWV. The process is repeated until full convergence in terms of both brachial pressures and PWV is reached. To assess the accuracy of the proposed framework, we implemented the algorithm on in vivo anonymized data from 20 subjects and compared the method-derived estimates of CO and cSBP to patient-specific measurements obtained with Mobil-O-Graph apparatus (central pressure) and two-dimensional transthoracic echocardiography (aortic blood flow). Results: Both CO and cSBP estimates were found to be in good agreement with the reference values achieving an RMSE of 0.36 L/min and 2.46 mmHg, respectively. Low biases were reported, namely -0.04±0.36 L/min for CO predictions and -0.27±2.51 mmHg for cSBP predictions. Significance: Our one-dimensional model can be successfully “tuned” to partially patient-specific standards by using noninvasive, easily obtained peripheral measurement data. The in vivo evaluation demonstrated that this method can potentially be used to obtain central aortic hemodynamic parameters in a noninvasive and accurate way.Keywords
This publication has 72 references indexed in Scilit:
- Aortic Stiffness, Blood Pressure Progression, and Incident HypertensionJAMA, 2012
- Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signalFrontiers in Physiology, 2012
- Validation of the mobil-O-Graph: 24 h-blood pressure measurement deviceBlood Pressure Monitoring, 2010
- Noninvasive Measurement of Central Vascular Pressures With Arterial Tonometry: Clinical Revival of the Pulse Pressure Waveform?Mayo Clinic Proceedings, 2010
- An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveformAmerican Journal of Physiology-Heart and Circulatory Physiology, 2009
- Clinical review: Goal-directed therapy in high risk surgical patientsCritical Care, 2009
- An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgeryAnaesthesia, 2007
- Better Management of Cardiovascular Diseases by Pulse Wave Velocity: Combining Clinical Practice with Clinical Research using Evidence-Based MedicineClinical Medicine & Research, 2007
- Sensitivity analysis of complex kinetic systems. Tools and applicationsJournal of Mathematical Chemistry, 1990
- A Viscoelastic Model for Use in Predicting Arterial Pulse WavesJournal of Biomechanical Engineering, 1980