Hydrodynamical evaluation of microporous covered stent for the treatment of intracranial aneurysms: Comparison of flow reduction property with flow diverter stent by using particle imaging velocimetry and in vitro flow simulator
Open Access
- 1 January 2018
- journal article
- Published by Japanese Society of Biorheology in Journal of Biorheology
- Vol. 32 (1) , 20-25
Abstract
We have developed a microporous covered stent (MCS) for the treatment of intracranial aneurysms (IAs). MCS promotes intentional thrombosis in the IA by blood stagnation and facilitates IA embolization treatment by clotting of whole blood in the IA. Flow reduction is a key property of such stent-type IA embolization devices. In this study, we evaluated the flow reduction property of MCS, and compered that of a general balloon expandable stent (bare stent, BS) for supporting a stenotic vessel and a typical flow diverter stent (FD) for IA treatment. This was carried out using particle imaging velocimetry (PIV) and an in vitro flow simulator with a saccular IA and straight parent vessel model. The PIV results show that the area mean shear rates in the IA flow were reduced to 34.7% (5.56 s–1) for the BS model, 9.2% (1.48 s–1) for the FD model, and 2.7% (0.43 s–1) for the MCS model with respect to the unstented condition (16.04 s–1) at a Reynolds number of 600. Considering that the flow reduction property of the MCS model is three times higher than that of the FD model, it is clear that the MCS facilitates more reliable IA embolization than FD.Keywords
This publication has 16 references indexed in Scilit:
- Hemodynamic transition driven by stent porosity in sidewall aneurysmsJournal of Biomechanics, 2015
- Particle Imaging Velocimetry Evaluation of Intracranial Stents in Sidewall Aneurysm: Hemodynamic Transition Related to the Stent DesignPLOS ONE, 2014
- Surpass Flow Diverter in the Treatment of Intracranial Aneurysms: A Prospective Multicenter StudyAmerican Journal of Neuroradiology, 2014
- Occlusion of canine aneurysms using microporous self-expanding stent grafts: Long-term follow-upClinical Neurology and Neurosurgery, 2014
- Stent-Assisted Coiling versus Coiling in Treatment of Intracranial Aneurysm: A Systematic Review and Meta-AnalysisPLOS ONE, 2014
- The Pipeline embolization device for treatment of intracranial aneurysmsExpert Review of Medical Devices, 2013
- Development of Microporous Covered Stent for Cerebral Aneurysm Treatment (Hydrodynamical Evaluation of Stent Embolization and Optimization of Pore Design of Microporous Film)TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B, 2013
- Rheological study on coagulation of blood with special reference to the triggering mechanism of venous thrombus formationJournal of Biorheology, 2009
- High-performance self-expanding stent graft: development and application to experimental aneurysmsJournal of Artificial Organs, 2009
- The Most Profitable Use of Flow Visualization in the Elimination of Thrombus from a Monopivot Magnetic Suspension Blood PumpArtificial Organs, 2004