    Experimental study on the effects of dielectric layer thickness and elastic modulus on the performance of flexible capacitive sensor films

    by Takeshi Moriwaki, Taiga Nakano

    A stenosed blood vessel with a calcified part has complex shape and deformation properties. When using a catheter device in the blood vessel, a large deformation occurs, so the sensor needs to be flexible, and film sensors are used for contact force and pressure measurements during in vitro evaluations. Various flexible film sensors are available. However, capacitive sensors are widely used because of their simple structure and low power consumption. When using a balloon catheter in a calcified vessel, wide range of contact pressure may act on blood vessels, such as poor contact (less than the order of 1 kPa) and stress concentration areas (more than the order of 100 kPa). In this study, the performance of a capacitive film sensor is investigated over a wide pressure range 1–1000 kPa by focusing on the thickness and elastic modulus of its dielectric layer. The sensitivity of capacitance change is high for sensors with thin and soft dielectric layers. However, the sensor is considered to be more affected by creep deformation. The sensor can detect the contact pressure between the balloon catheter and the model vessel during balloon dilation. During the use of catheter devices through in vitro experiments using flexible film sensors, quantitative measurement of the load on blood vessels is useful for acquiring knowledge for application in clinical device selection and mechanical evaluation testing during new device development.

  • Damage Analysis in Ag Nanoparticle Interconnect Line Under High-Density Electric Current

    by Daiki Saito, Kazuhiko Sasagawa, Takeshi Moriwaki, Kazuhiro Fujisaki

    Printed electronics (PEs) have attracted attention for the fabrication of microscale electronic circuits. PEs use conductive inks which include metal nanoparticles. The conductive ink can be printed on flexible substrates for wearable devices using ink-jet printers and roll-to-roll methods. With the scaling down of electric devices, the current density and Joule heating in the device lines increase, and electromigration (EM) damage becomes significant. EM is a transportation phenomenon of metallic atoms caused by the electron wind under high-density current. Reducing the EM damage is extremely important to enhance the device reliability. With the progress in miniaturization of the metal nanoparticle ink lines, EM problem needs to be solved for ensuring the reliability of these lines. We know that the formation of aggregates and cathode damages occur due to a current loading. The diffusion path of atoms due to the EM has not been identified under the high-density current loading. In this study, a high-density electric current loading was applied to an Ag nanoparticle line. The line specimens were prepared using a lift-off method. After the current loading tests, observations were conducted using a laser microscope and scanning electron microscope. A local decrease in the line thickness and scale-shaped slit-like voids were observed due to the high-density current loading. Moreover, the microstructure of the line was modified by enlarging the Ag grain. From the results, we identified that a dominant diffusion occurred at the Ag grain boundary due to the EM.


  • Open Access

    In Vitro Measurement of Contact Pressure Applied to a Model Vessel Wall during Balloon Dilation by Using a Film-Type Sensor

    by Takeshi Moriwaki, Yoshihiro Okamoto, Hiroo Yamaga, Kazuhiro Fujisaki, Miyuki Uematsu, Hideyuki Sakoda, Yuji Haishima

    Objective: As an important evaluation index of vascular damage, the study aims to clarify the value of contact pressure applied to blood vessels and how it changes with respect to balloon pressure during balloon dilation. Methods: The contact pressure was evaluated through an in vitro measurement system using a model tube with almost the same elastic modulus as the blood vessel wall and our film-type pressure sensor. A poly (vinyl alcohol) hydrogel tube with almost the same elastic modulus was fabricated as the model vessel. The film-type sensor was inserted between the balloon catheter and the model vessel, and the balloon was dilated. Results: The contact pressure applied to the blood vessel was less than 10% of the balloon pressure, and the increase in contact pressure was less than 1% of the increase in balloon pressure (8 to 14 atm). Moreover, the contact pressure and its increase were larger in the model with a high elastic modulus. Conclusion: The contact pressure to expand the soft vessel model was not high, and the balloon pressure almost appeared to act on the expansion of the balloon itself. Our experiment using variable stiffness vessel models containing film-type sensors showed that the contact pressure acting on the vessel wall tended to increase as the wall became harder, even when the nominal diameter of the balloon was almost identical to the vessel. Our results can be clinically interpreted: when a vessel is stiff, the high-pressure inflation may rupture it even if its nominal diameter is identical to the diameter of the vessel.


  • Electromigration Damage of Flexible Electronic Lines Printed With Ag Nanoparticle Ink

    by Daiki Saito, Kazuhiko Sasagawa, Takeshi Moriwaki, Kazuhiro Fujisaki

    Flexible printed circuits (FPCs) are widely used in electronic equipment such as mobile devices and wearable sensors. The conductive electric lines in these circuits are printed using nanoparticle metal ink and ink-jet direct write methods. Physical characteristics such as flexibility and mechanical durability of metal nanoparticle ink lines have been evaluated by bending or tensile tests. In contrast, the electrical characteristics of these lines have not been sufficiently evaluated, and the failure mechanism under high-density current has not been clarified. When electric devices are scaled down, current density and Joule heating increase in conductive lines and electromigration (EM) damage becomes a severe problem. Therefore, reducing the EM damage is extremely important to enhance the device reliability. In this study, a failure analysis of Ag nanoparticle ink lines were assessed using current loading tests and microscopic observations to discuss the damage mechanism and evaluate electrical reliability under high-density current. Atomic transport due to EM was observed at 60 kA/cm2 current loading, and relatively large aggregates and grain growth were observed at 120 kA/cm2 current loading. The time to open circuit was longer at 120 kA/cm2 than at 60 kA/cm2. The formation of large aggregates and unstable changes in the potential drop were observed at the two values of current density. It is considered that aggregate formation and grain growth affected the atomic transport by EM.


  • Anode-Side Failure of a Cuprous Oxide Semiconductor Caused by High-Density Current Loading

    by Takeshi Moriwaki, Kazuhiko Sasagawa, Yusuke Sugawara, Kazuhiro Fujisaki, Takahiro Mineta


  • Open Access

    Hydrodynamical evaluation of microporous covered stent for the treatment of intracranial aneurysms: Comparison of flow reduction property with flow diverter stent by using particle imaging velocimetry and in vitro flow simulator

    by Takeshi Moriwaki, Tsutomu Tajikawa, Yasuhide Nakayama

    We have developed a microporous covered stent (MCS) for the treatment of intracranial aneurysms (IAs). MCS promotes intentional thrombosis in the IA by blood stagnation and facilitates IA embolization treatment by clotting of whole blood in the IA. Flow reduction is a key property of such stent-type IA embolization devices. In this study, we evaluated the flow reduction property of MCS, and compered that of a general balloon expandable stent (bare stent, BS) for supporting a stenotic vessel and a typical flow diverter stent (FD) for IA treatment. This was carried out using particle imaging velocimetry (PIV) and an in vitro flow simulator with a saccular IA and straight parent vessel model. The PIV results show that the area mean shear rates in the IA flow were reduced to 34.7% (5.56 s–1) for the BS model, 9.2% (1.48 s–1) for the FD model, and 2.7% (0.43 s–1) for the MCS model with respect to the unstented condition (16.04 s–1) at a Reynolds number of 600. Considering that the flow reduction property of the MCS model is three times higher than that of the FD model, it is clear that the MCS facilitates more reliable IA embolization than FD.