Admission Cardiotocography as a Predictor of Low Apgar Score: An Observational, Cross-Sectional Study
Open Access
- 17 April 2021
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 13 (4)
Abstract
Background and objective Cardiotocography (CTG) has been used more frequently in recent decades to reduce intrapartum fetal mortality rates. The purpose of this study was to determine whether pathological or non-reactive CTG could predict a low Apgar (Appearance, Pulse, Grimace, Activity, and Respiration) score. An abnormal trace would indicate a distressed fetus, whereas a normal trace would indicate a well-oxygenated fetus. Methods This study included a total of 470 women with a gestational period of more than 37 weeks. Based on the results of their CTGs, they were divided into three groups. An emergency cesarean section (CS) was performed if there was any sign of fetal distress on CTG. The Apgar scoring for newborns was recorded in the proforma following delivery. Results The study was carried out at two major tertiary-care hospitals in Pakistan. A reactive CTG was found in more than one-third (39.36%) of the 470 patients. An Apgar score above 8 was obtained by 34.26% of the newborns, while an Apgar score below 8 was obtained by more than half (63.40%). Only 2.34% of newborns had an Apgar score below 6. A third (30.64%) of the patients had grade-1 meconium-stained liquor (MSL), 24.89% had grade-2 MSL, 19.79% had grade-3 MSL, and 24.68% had no MSL. One-third (32.34%) of the neonates were admitted to the neonatal intensive care unit (NICU) shortly after birth. When CTG was pathological or non-reactive, the odds of securing a higher Apgar score decreased by 70.45% (OR: 0.30; 95% CI: 0.20-0.44; p<0.001). Conclusion The main conclusion drawn from this study's findings is that a pathological CTG is an indicator of a low Apgar score.Keywords
This publication has 14 references indexed in Scilit:
- The long-term outcome in surviving infants with Apgar zero at 10 minutes: a systematic review of the literature and hospital-based cohortAmerican Journal of Obstetrics and Gynecology, 2007
- Admission cardiotocography versus intermittent auscultation of fetal heart rate: Effects on neonatal Apgar score, on the rate of caesarean sections and on the rate of instrumental delivery—A systematic reviewInternational Journal of Nursing Studies, 2006
- Prognostic value of the labour admission test and its effectiveness compared with auscultation only: a systematic reviewBJOG: An International Journal of Obstetrics & Gynaecology, 2005
- The National Institute of Clinical Excellence (NICE) guidelines for caesarean sections: implications for the anaesthetistInternational Journal of Obstetric Anesthesia, 2005
- Temporal and demographic trends in cerebral palsy—Fact and fictionAmerican Journal of Obstetrics and Gynecology, 2003
- Admission cardiotocography: a randomised controlled trialThe Lancet, 2003
- Randomised controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk obstetric populationCommentary: changes between protocol and manuscript should be declared at submissionCommentary: research governance must focus on research trainingCommentary: Approach to power calculations has to be realisticBMJ, 2001
- Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: A meta-analysisObstetrics & Gynecology, 1995
- The accuracy of auscultatory detection of fetal cardiacdecelerations: A computer simulationAmerican Journal of Obstetrics and Gynecology, 1992
- THE SIGNIFICANCE OF THE CHANGES IN THE CONTINUOUS FETAL HEART RATE IN THE FIRST STAGE OF LABOURBJOG: An International Journal of Obstetrics & Gynaecology, 1971