Micro‐CT artifacts reduction based on detector random shifting and fast data inpainting
Authors:
- Mengliu ZhaoMZMengliu Zhao
- Hongwei LiHLHongwei Li
- Peng ZhangPZPeng Zhang
- 28 February 2013
- journal article
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031114
Abstract
Purpose:: In Micro‐CT systems based on optical coupling detectors, the defects of scintillator or CCD‐camera would lead to heavy artifacts in reconstructed CT images. Meanwhile, different detector units usually suffer from inhomogeneous response, which also leads to artifacts in the CT images. Detector shifting is a simple and efficient method to remove the artifacts due to inhomogeneous responses of detector units. However, it does not work well for heavy artifacts due to defects in scintillator or CCD. The purpose of this paper is to develop a data preprocessing method to reduce both kinds of artifacts.Methods:: A hybrid method which involves detector random shifting and data inpainting is proposed to correct the projection data, so as to suppress the artifacts in the reconstructed CT images. The defects in scintillator or CCD‐camera lead to data lost in some areas of the projection data. The Criminisi algorithm is employed to recover the lost data. By detector random shifting, the location of the lost data in one view might be shifted away in adjacent views. This feature is utilized to design the search window, such that the best match patch shall be searched across adjacent views. By this way, the best match patches should really enjoy high similarity. As a result, the heavy artifacts due to defects of scintillator or CCD‐camera should be suppressed. Furthermore, a multiscale tessellation method is proposed to locate the defects and similarity patches, which makes the Criminisi algorithm very fast.Results:: The authors tested the proposed method on both simulated projection data and real projection data. Experiments show that the proposed method could correct the bad data in the projections quite well. Compared to other popular methods, such as linear interpolation, wavelet combining Fourier transform, and TV‐inpainting, experimental results suggest that the CT images reconstructed from the preprocessed data sets by our method is significantly better in quality.Conclusions:: They have proposed a hybrid method for projection data preprocessing which fits well to typical Micro‐CT systems. The hybrid method could suppress the ring artifacts in the reconstructed CT images efficiently, while the spatial resolution is not reduced even with a critical eye.Keywords
Funding Information
- NNSFC (61127003, 60972140, 60971131)
- Beijing Education Committee (PHR20110509, KZ201110028034)
This publication has 20 references indexed in Scilit:
- An improved method for the removal of ring artifacts in high resolution CT imagingEURASIP Journal on Advances in Signal Processing, 2012
- Stripe and ring artifact removal with combined wavelet—Fourier filteringOptics Express, 2009
- Tipping the balance: modulating the Wnt pathway for tissue repairTrends in Biotechnology, 2009
- GPU‐Based 3D Cone‐Beam CT Image Reconstruction for Large Data VolumeInternational Journal of Biomedical Imaging, 2009
- Spectral filtering as a method of visualising and removing striped artefacts in digital elevation dataEarth Surface Processes and Landforms, 2007
- Scintillation detectors for x-raysMeasurement Science and Technology, 2006
- Region Filling and Object Removal by Exemplar-Based Image InpaintingIEEE Transactions on Image Processing, 2004
- Nontexture Inpainting by Curvature-Driven DiffusionsJournal of Visual Communication and Image Representation, 2001
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984
- Simultaneous Algebraic Reconstruction Technique (SART): A superior implementation of the ART algorithmUltrasonic Imaging, 1984