Vitamin E‐stabilized polyethylene shows similar survival rates at minimum 7‐year follow‐up compared to conventional polyethylene in primary total knee arthroplasty
Open Access
- 1 July 2024
- journal article
- research article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 11 (3) , e12106
Abstract
Purpose: The aim of this cross‐sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E‐stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7‐year follow‐up.Methods: Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow‐up. American Knee Society Score (KSS), Forgotten Joint Score (FJS‐12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow‐up. Any revision, reintervention or other complications were recorded.Results: Among 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow‐up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10‐year follow‐up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.Conclusion: TKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10‐year follow‐up.Level of Evidence: Level III.Keywords
This publication has 33 references indexed in Scilit:
- The “Forgotten Joint” as the Ultimate Goal in Joint ArthroplastyThe Journal of Arthroplasty, 2012
- Does Vitamin E–Stabilized Ultrahigh-Molecular-Weight Polyethylene Address Concerns of Cross-Linked Polyethylene in Total Knee Arthroplasty?The Journal of Arthroplasty, 2011
- The relative effects of radiation crosslinking and type of counterface on the wear resistance of ultrahigh-molecular-weight polyethyleneActa Biomaterialia, 2011
- The Use of Highly Cross-linked Polyethylene in Total Knee ArthroplastyJournal of the American Academy of Orthopaedic Surgeons, 2011
- Vitamin E diffused, highly crosslinked UHMWPE: a reviewInternational Orthopaedics, 2010
- Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement componentsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- Characterization of irradiated blends of -tocopherol and UHMWPEBiomaterials, 2005
- The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplastyThe Journal of Arthroplasty, 1999
- Rationale, of The Knee Society Clinical Rating SystemClinical Orthopaedics and Related Research, 1989
- The radiolucent line beneath the tibial components of the Oxford meniscal knee.1984