Marta Colombo
Marta Colombo has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Lorenzo Banci
Clinical Department, Permedica Orthopaedics, 23807 Merate, Italy
2 shared publications - Alessandra Cipolla
Service de Chirurgie orthopédique Centre Hospitalier de Briançon, 24 Av. Adrien Daurelle, 05100, Briançon, France
1 shared publication - Alessandro Bistolfi
Department of Traumatology and Rehabilitation, C.T.O. Hospital-A.O.U. Città della Salute e della Scienza, Via Zuretti 29, 10126 Turin, Italy
1 shared publication - Alessandro Massè
University of Turin, Turin, Italy
1 shared publication - Alex Pizzo
Department of Orthopaedic Surgery, Ospedale Maggiore Carlo Alberto Pizzardi, 40133 Bologna, Italy
1 shared publication - Andrea Assenza
Department of Orthopaedic Surgery, Ospedale Maggiore Carlo Alberto Pizzardi, 40133 Bologna, Italy
1 shared publication
Latest Publications
- Open Access
- 20 September 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (9) , 634
Novel Clinical Applications of 3D-Printed Highly Porous Titanium for Off-the-Shelf Cementless Joint Replacement Prostheses
In total joint replacement, early aseptic loosening of implants caused by inadequate initial fixation and late aseptic loosening due to stress shielding-related periprosthetic bone remodeling are the main causes of failure. Over the last two decades, additive manufacturing has been revolutionizing the design of cementless orthopaedic implants by enabling biomimetic, highly porous titanium structures that enhance bone ingrowth and osseointegration while reducing stress shielding. The synergy between optimized selective laser-melted highly porous titanium bearing components, ceramic-coated titanium articular surfaces, and vitamin E-stabilized polyethylene liners delivers several benefits essential for implant longevity: reliable initial fixation, improved biological fixation, reduced bone resorption caused by stress shielding, and lower osteolytic reactivity. These benefits have encouraged the synergetic use of these technologies in joint replacement in novel clinical applications. In recent years, novel off-the-shelf, 3D-printed, highly porous titanium implants have been introduced into hip and knee arthroplasty. These newly introduced implants appear to offer an innovative and promising solution, and are particularly indicated for young active patients, elderly patients with osteoporotic bones, and in complex cases. Future clinical research should confirm these novel implants’ superior results in comparison to the current state of the art in cementless joint replacement. The possibility of extending these technologies in the future to other clinical applications such as partial knee prosthesis is discussed.
- 20 September 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (9) , 634
Open AccessNovel Clinical Applications of 3D-Printed Highly Porous Titanium for Off-the-Shelf Cementless Joint Replacement Prostheses
In total joint replacement, early aseptic loosening of implants caused by inadequate initial fixation and late aseptic loosening due to stress shielding-related periprosthetic bone remodeling are the main causes of failure. Over the last two decades, additive manufacturing has been revolutionizing the design of cementless orthopaedic implants by enabling biomimetic, highly porous titanium structures that enhance bone ingrowth and osseointegration while reducing stress shielding. The synergy between optimized selective laser-melted highly porous titanium bearing components, ceramic-coated titanium articular surfaces, and vitamin E-stabilized polyethylene liners delivers several benefits essential for implant longevity: reliable initial fixation, improved biological fixation, reduced bone resorption caused by stress shielding, and lower osteolytic reactivity. These benefits have encouraged the synergetic use of these technologies in joint replacement in novel clinical applications. In recent years, novel off-the-shelf, 3D-printed, highly porous titanium implants have been introduced into hip and knee arthroplasty. These newly introduced implants appear to offer an innovative and promising solution, and are particularly indicated for young active patients, elderly patients with osteoporotic bones, and in complex cases. Future clinical research should confirm these novel implants’ superior results in comparison to the current state of the art in cementless joint replacement. The possibility of extending these technologies in the future to other clinical applications such as partial knee prosthesis is discussed.
- Open Access
- 1 July 2024
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 11 (3) , e12106
Vitamin E‐stabilized polyethylene shows similar survival rates at minimum 7‐year follow‐up compared to conventional polyethylene in primary total knee arthroplasty
Purpose: The aim of this cross‐sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E‐stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7‐year follow‐up.Methods: Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow‐up. American Knee Society Score (KSS), Forgotten Joint Score (FJS‐12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow‐up. Any revision, reintervention or other complications were recorded.Results: Among 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow‐up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10‐year follow‐up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.Conclusion: TKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10‐year follow‐up.Level of Evidence: Level III.
- 1 July 2024
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 11 (3) , e12106
Open AccessVitamin E‐stabilized polyethylene shows similar survival rates at minimum 7‐year follow‐up compared to conventional polyethylene in primary total knee arthroplasty
Purpose: The aim of this cross‐sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E‐stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7‐year follow‐up.Methods: Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow‐up. American Knee Society Score (KSS), Forgotten Joint Score (FJS‐12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow‐up. Any revision, reintervention or other complications were recorded.Results: Among 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow‐up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10‐year follow‐up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.Conclusion: TKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10‐year follow‐up.Level of Evidence: Level III.
- Open Access
- 1 March 2024
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 116 (C) , 109375
Hip arthrodesis conversion to dual mobility total hip arthroplasty in a young adult using a custom-made highly-porous titanium monobloc cup: A case report
Introduction: Conversion of hip arthrodesis to total hip arthroplasty (THA) is an effective but challenging procedure to restore hip functionality and improve quality of life. Herein, a case of arthrodesis takedown to a dual mobility THA with a custom-made 3D-printed cup. Presentation of case: Due to higher risk of instability and loosening for the altered and atrophic anatomy, a custom-made highly-porous titanium dual mobility monobloc cup has been used for a cementless conversion THA in 31-year-old patient with hip arthrodesis. At 3-year follow-up clinical and radiographic results were excellent with the custom-made implant found stable and well osseointegrated. Discussion: To the best of our knowledge, this is the first case of arthrodesis conversion to THA with custom-made highly-porous dual mobility cup in a young adult. The dual mobility construct helped reducing the risk of dislocation, while the highly-porous structure reduced the risk of aseptic loosening. Conclusion: The use of cementless highly-porous dual mobility implant in complex cases young patients is supported. Highlights:
- 1 March 2024
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 116 (C) , 109375
Open AccessHip arthrodesis conversion to dual mobility total hip arthroplasty in a young adult using a custom-made highly-porous titanium monobloc cup: A case report
Introduction: Conversion of hip arthrodesis to total hip arthroplasty (THA) is an effective but challenging procedure to restore hip functionality and improve quality of life. Herein, a case of arthrodesis takedown to a dual mobility THA with a custom-made 3D-printed cup. Presentation of case: Due to higher risk of instability and loosening for the altered and atrophic anatomy, a custom-made highly-porous titanium dual mobility monobloc cup has been used for a cementless conversion THA in 31-year-old patient with hip arthrodesis. At 3-year follow-up clinical and radiographic results were excellent with the custom-made implant found stable and well osseointegrated. Discussion: To the best of our knowledge, this is the first case of arthrodesis conversion to THA with custom-made highly-porous dual mobility cup in a young adult. The dual mobility construct helped reducing the risk of dislocation, while the highly-porous structure reduced the risk of aseptic loosening. Conclusion: The use of cementless highly-porous dual mobility implant in complex cases young patients is supported. Highlights: