A magnetic flux leakage testing system based on the magnetoreactance effect was established to detect the rectangular crack in a martensitic stainless steel. Detection of the transverse rectangular crack was achieved through probing the magnetic leakage fields arisen from the crack using the magnetoreactance sensing system. This system was able to detect a small crack with a width of 1 mm and a depth of 1.5 mm even at a low frequency of 100 kHz. The influences of the exciting-current intensity, the sensing direction and the testing distance on the detection sensitivity in magnetic flux leakage testing were studied in this work. It was found that the magnetic leakage signal strength increased with increasing the exciting-current intensity. We also found that the magnetoreactance sensor was more sensitive to the magnetic leakage fields when it was tested perpendicularly to the crack.
Funding Information
  • Shanghai Young University Teacher Training Subsidy Program (37010917203)
  • the National Youth Natural Science Foundation (61703266)
  • the Shanghai Natural Science Foundation (17ZR1409700)
  • The National Natural Science Foundation of China (51575333, 51675321, 61525305, 61573236)