Yong Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yong Zhou has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Chong Lei
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Department of Micro-Nano Electronics, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
13 shared publications Chong Lei
Key Laboratory for Thin Film and Microfahrication of Ministry of Education, Research Institute of Micro/Nano Science and Technology, Shanghai JiaoTong University, Shanghai, China
11 shared publications- Zhen Yang
Shanghai Jiao Tong University
10 shared publications Jian Lei
Shanghai Jiao Tong University
8 shared publicationsTao Wang
Shanghai Jiao Tong University
6 shared publicationsWen Ding
Institute of Micro/Nano Science and Technology, Shanghai Jiao Tong University, DongChuan Road 800, Shanghai 200240, P. R. China
6 shared publications
Latest Publications
- Open Access
Reconfigurable Intelligent Surfaces Empowered Green Wireless Networks with User Admission Control
Reconfigurable intelligent surface (RIS) has emerged as a cost-effective and energy-efficient technique for 6G. By adjusting the phase shifts of passive reflecting elements, RIS is capable of suppressing the interference and combining the desired signals constructively at receivers, thereby significantly enhancing the performance of communication system. In this paper, we consider a green multi-user multi-antenna cellular network, where multiple RISs are deployed to provide energy-efficient communication service to end users. We jointly optimize the phase shifts of RISs, beamforming of the base stations, and the active RIS set with the aim of minimizing the power consumption of the base station (BS) and RISs subject to the quality of service (QoS) constraints of users and the transmit power constraint of the BS. However, the problem is mixed combinatorial and non-convex, and there is a potential infeasibility issue when the QoS constraints cannot be guaranteed by all users. To deal with the infeasibility issue, we further investigate a user admission control problem to jointly optimize the transmit beamforming, RIS phase shifts, and the admitted user set. Specifically, we first decompose the original non-convex problem into several rank-one constrained optimization subproblems via matrix lifting. A difference-of-convex (DC) algorithm is then developed to solve each decomposed subproblem. The proposed AO framework efficiently minimizes the power consumption of wireless networks as well as user admission control when the QoS constraints cannot be guaranteed by all users. To further address the complexity-sensitive issue for practical implementation, we propose an alternative low-complexity beamforming and RISs phase shifts design algorithm based on zero-forcing (ZF) to enable the green cellular networks.
Open AccessReconfigurable Intelligent Surfaces Empowered Green Wireless Networks with User Admission Control
Reconfigurable intelligent surface (RIS) has emerged as a cost-effective and energy-efficient technique for 6G. By adjusting the phase shifts of passive reflecting elements, RIS is capable of suppressing the interference and combining the desired signals constructively at receivers, thereby significantly enhancing the performance of communication system. In this paper, we consider a green multi-user multi-antenna cellular network, where multiple RISs are deployed to provide energy-efficient communication service to end users. We jointly optimize the phase shifts of RISs, beamforming of the base stations, and the active RIS set with the aim of minimizing the power consumption of the base station (BS) and RISs subject to the quality of service (QoS) constraints of users and the transmit power constraint of the BS. However, the problem is mixed combinatorial and non-convex, and there is a potential infeasibility issue when the QoS constraints cannot be guaranteed by all users. To deal with the infeasibility issue, we further investigate a user admission control problem to jointly optimize the transmit beamforming, RIS phase shifts, and the admitted user set. Specifically, we first decompose the original non-convex problem into several rank-one constrained optimization subproblems via matrix lifting. A difference-of-convex (DC) algorithm is then developed to solve each decomposed subproblem. The proposed AO framework efficiently minimizes the power consumption of wireless networks as well as user admission control when the QoS constraints cannot be guaranteed by all users. To further address the complexity-sensitive issue for practical implementation, we propose an alternative low-complexity beamforming and RISs phase shifts design algorithm based on zero-forcing (ZF) to enable the green cellular networks.
- Open Access
Gan-Based Joint Activity Detection and Channel Estimation For Grant-free Random Access
Joint activity detection and channel estimation (JADCE) for grant-free random access is a critical issue that needs to be addressed to support massive connectivity in IoT networks. However, the existing model-free learning method can only achieve either activity detection or channel estimation, but not both. In this paper, we propose a novel model-free learning method based on generative adversarial network (GAN) to tackle the JADCE problem. We adopt the U-net architecture to build the generator rather than the standard GAN architecture, where a pre-estimated value that contains the activity information is adopted as input to the generator. By leveraging the properties of the pseudoinverse, the generator is refined by using an affine projection and a skip connection to ensure the output of the generator is consistent with the measurement. Moreover, we build a two-layer fully-connected neural network to design pilot matrix for reducing the impact of receiver noise. Simulation results show that the proposed method outperforms the existing methods in high SNR regimes, as both data consistency projection and pilot matrix optimization improve the learning ability.
Open AccessGan-Based Joint Activity Detection and Channel Estimation For Grant-free Random Access
Joint activity detection and channel estimation (JADCE) for grant-free random access is a critical issue that needs to be addressed to support massive connectivity in IoT networks. However, the existing model-free learning method can only achieve either activity detection or channel estimation, but not both. In this paper, we propose a novel model-free learning method based on generative adversarial network (GAN) to tackle the JADCE problem. We adopt the U-net architecture to build the generator rather than the standard GAN architecture, where a pre-estimated value that contains the activity information is adopted as input to the generator. By leveraging the properties of the pseudoinverse, the generator is refined by using an affine projection and a skip connection to ensure the output of the generator is consistent with the measurement. Moreover, we build a two-layer fully-connected neural network to design pilot matrix for reducing the impact of receiver noise. Simulation results show that the proposed method outperforms the existing methods in high SNR regimes, as both data consistency projection and pilot matrix optimization improve the learning ability.
- Open Access
- 21 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 12817
Author Correction: An integrated microfluidic system using a micro-fluxgate and micro spiral coil for magnetic microbeads trapping and detecting
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.
- 21 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 12817
Open AccessAuthor Correction: An integrated microfluidic system using a micro-fluxgate and micro spiral coil for magnetic microbeads trapping and detecting
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.
- 8 August 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 215 (21)
Effect of Field Annealing Induced Magnetic Anisotropy on the Performance of Meander‐Core Orthogonal Fluxgate Sensor
The magnetic anisotropy field distribution is discussed for Co‐based amorphous ribbon annealed under different field conditions leading to different induced anisotropies: longitudinal field (LF) and transversal field (TF) annealing. In order to understand the relation between the field annealing‐induced anisotropy and the performance of meander‐core orthogonal fluxgate sensor, field‐annealed ribbons with different in‐plane anisotropies as cores of orthogonal fluxgate sensors are employed and both noise and sensitivity in fundamental mode are measured. Experimental results indicate that LF annealing‐induced anisotropy with easy axis perpendicular to the direction of excitation field can effectively improve the sensor sensitivity. On the other hand, TF annealing‐induced anisotropy with easy axis parallel to excitation field results in lower sensitivity, but the noise is also lower. The results obtained are useful for developing the high‐performance orthogonal fluxgate sensors based on amorphous ribbon cores.
- 8 August 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 215 (21)
Effect of Field Annealing Induced Magnetic Anisotropy on the Performance of Meander‐Core Orthogonal Fluxgate Sensor
The magnetic anisotropy field distribution is discussed for Co‐based amorphous ribbon annealed under different field conditions leading to different induced anisotropies: longitudinal field (LF) and transversal field (TF) annealing. In order to understand the relation between the field annealing‐induced anisotropy and the performance of meander‐core orthogonal fluxgate sensor, field‐annealed ribbons with different in‐plane anisotropies as cores of orthogonal fluxgate sensors are employed and both noise and sensitivity in fundamental mode are measured. Experimental results indicate that LF annealing‐induced anisotropy with easy axis perpendicular to the direction of excitation field can effectively improve the sensor sensitivity. On the other hand, TF annealing‐induced anisotropy with easy axis parallel to excitation field results in lower sensitivity, but the noise is also lower. The results obtained are useful for developing the high‐performance orthogonal fluxgate sensors based on amorphous ribbon cores.
- Open Access
- 30 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0194631
A sensitive and innovative detection method for rapid C-reactive proteins analysis based on a micro-fluxgate sensor system
A sensitive and innovative assay system based on a micro-MEMS-fluxgate sensor and immunomagnetic beads-labels was developed for the rapid analysis of C-reactive proteins (CRP). The fluxgate sensor presented in this study was fabricated through standard micro-electro-mechanical system technology. A multi-loop magnetic core made of Fe-based amorphous ribbon was employed as the sensing element, and 3-D solenoid copper coils were used to control the sensing core. Antibody-conjugated immunomagnetic microbeads were strategically utilized as signal tags to label the CRP via the specific conjugation of CRP to polyclonal CRP antibodies. Separate Au film substrates were applied as immunoplatforms to immobilize CRP-beads labels through classical sandwich assays. Detection and quantification of the CRP at different concentrations were implemented by detecting the stray field of CRP labeled magnetic beads using the newly-developed micro-fluxgate sensor. The resulting system exhibited the required sensitivity, stability, reproducibility, and selectivity. A detection limit as low as 0.002 μg/mL CRP with a linearity range from 0.002 μg/mL to 10 μg/mL was achieved, and this suggested that the proposed biosystem possesses high sensitivity. In addition to the extremely low detection limit, the proposed method can be easily manipulated and possesses a quick response time. The response time of our sensor was less than 5 s, and the entire detection period for CRP analysis can be completed in less than 30 min using the current method. Given the detection performance and other advantages such as miniaturization, excellent stability and specificity, the proposed biosensor can be considered as a potential candidate for the rapid analysis of CRP, especially for point-of-care platforms.
- 30 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0194631
Open AccessA sensitive and innovative detection method for rapid C-reactive proteins analysis based on a micro-fluxgate sensor system
A sensitive and innovative assay system based on a micro-MEMS-fluxgate sensor and immunomagnetic beads-labels was developed for the rapid analysis of C-reactive proteins (CRP). The fluxgate sensor presented in this study was fabricated through standard micro-electro-mechanical system technology. A multi-loop magnetic core made of Fe-based amorphous ribbon was employed as the sensing element, and 3-D solenoid copper coils were used to control the sensing core. Antibody-conjugated immunomagnetic microbeads were strategically utilized as signal tags to label the CRP via the specific conjugation of CRP to polyclonal CRP antibodies. Separate Au film substrates were applied as immunoplatforms to immobilize CRP-beads labels through classical sandwich assays. Detection and quantification of the CRP at different concentrations were implemented by detecting the stray field of CRP labeled magnetic beads using the newly-developed micro-fluxgate sensor. The resulting system exhibited the required sensitivity, stability, reproducibility, and selectivity. A detection limit as low as 0.002 μg/mL CRP with a linearity range from 0.002 μg/mL to 10 μg/mL was achieved, and this suggested that the proposed biosystem possesses high sensitivity. In addition to the extremely low detection limit, the proposed method can be easily manipulated and possesses a quick response time. The response time of our sensor was less than 5 s, and the entire detection period for CRP analysis can be completed in less than 30 min using the current method. Given the detection performance and other advantages such as miniaturization, excellent stability and specificity, the proposed biosensor can be considered as a potential candidate for the rapid analysis of CRP, especially for point-of-care platforms.
- 19 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Magnetics Letters
- Vol. 9 (1949307X) , 1-4
Detection of a Rectangular Crack in Martensitic Stainless Steel Using a Magnetoreactance Sensing System
A magnetic flux leakage testing system based on the magnetoreactance effect was established to detect the rectangular crack in a martensitic stainless steel. Detection of the transverse rectangular crack was achieved through probing the magnetic leakage fields arisen from the crack using the magnetoreactance sensing system. This system was able to detect a small crack with a width of 1 mm and a depth of 1.5 mm even at a low frequency of 100 kHz. The influences of the exciting-current intensity, the sensing direction and the testing distance on the detection sensitivity in magnetic flux leakage testing were studied in this work. It was found that the magnetic leakage signal strength increased with increasing the exciting-current intensity. We also found that the magnetoreactance sensor was more sensitive to the magnetic leakage fields when it was tested perpendicularly to the crack.
- 19 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Magnetics Letters
- Vol. 9 (1949307X) , 1-4
Detection of a Rectangular Crack in Martensitic Stainless Steel Using a Magnetoreactance Sensing System
A magnetic flux leakage testing system based on the magnetoreactance effect was established to detect the rectangular crack in a martensitic stainless steel. Detection of the transverse rectangular crack was achieved through probing the magnetic leakage fields arisen from the crack using the magnetoreactance sensing system. This system was able to detect a small crack with a width of 1 mm and a depth of 1.5 mm even at a low frequency of 100 kHz. The influences of the exciting-current intensity, the sensing direction and the testing distance on the detection sensitivity in magnetic flux leakage testing were studied in this work. It was found that the magnetic leakage signal strength increased with increasing the exciting-current intensity. We also found that the magnetoreactance sensor was more sensitive to the magnetic leakage fields when it was tested perpendicularly to the crack.
- Open Access
- 11 October 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 12967
An integrated microfluidic system using a micro-fluxgate and micro spiral coil for magnetic microbeads trapping and detecting
We report an innovative integrated microfluidic platform based on micro-fluxgate and micro-coils for trapping and detecting magnetic beads. A micro-spiral coil fabricated by microfabrication technology is used to trap the magnetic beads, and the micro-fluxgate is employed to detect the weak magnetic field induced by the trapped magnetic beads. The fabrication process of the magnetic bead trapping system using a micro-coil is highly compatible with that of the micro-fluxgate sensor, making fabrication of this integrated microfluidic system convenient and efficient. It is observed that the magnetic bead trapping ratio increases as the number of magnetic beads is increased with a flow rate of 5 to 16.5 μL·min−1. Samples spiked with different concentrations of magnetic beads can be distinguished clearly using the micro-fluxgate sensor in this microfluidic system. In this study, the results demonstrate that the microfluidic system traps and detects magnetic beads efficiently and is a promising candidate for biomarker capture and detection.
- 11 October 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 12967
Open AccessAn integrated microfluidic system using a micro-fluxgate and micro spiral coil for magnetic microbeads trapping and detecting
We report an innovative integrated microfluidic platform based on micro-fluxgate and micro-coils for trapping and detecting magnetic beads. A micro-spiral coil fabricated by microfabrication technology is used to trap the magnetic beads, and the micro-fluxgate is employed to detect the weak magnetic field induced by the trapped magnetic beads. The fabrication process of the magnetic bead trapping system using a micro-coil is highly compatible with that of the micro-fluxgate sensor, making fabrication of this integrated microfluidic system convenient and efficient. It is observed that the magnetic bead trapping ratio increases as the number of magnetic beads is increased with a flow rate of 5 to 16.5 μL·min−1. Samples spiked with different concentrations of magnetic beads can be distinguished clearly using the micro-fluxgate sensor in this microfluidic system. In this study, the results demonstrate that the microfluidic system traps and detects magnetic beads efficiently and is a promising candidate for biomarker capture and detection.
- 5 July 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (4) , 1-7
Investigation of contactless detection using a giant magnetoresistance sensor for detecting prostate specific antigen
This paper presents a contactless detection method for detecting prostate specific antigen with a giant magnetoresistance sensor. In contactless detection case, the prostate specific antigen sample preparation was separated from the sensor that prevented the sensor from being immersed in chemical solvents, and made the sensor implementing in immediately reuse without wash. Experimental results showed that applied an external magnetic field in a range of 50 Oe to 90 Oe, Dynabeads with a concentration as low as 0.1 μg/mL can be detected by this system and could give an approximate quantitation to the logarithmic of Dynabeads concentration. Sandwich immunoassay was employed for preparing PSA samples. The PSA capture was implemented on a gold film modified with a self-assembled monolayer and using biotinylated secondary antibody against PSA and streptavidinylated Dynabeads. With DC magnetic field in the range of 50 to 90 Oe, PSA can be detected with a detection limit as low as 0.1 ng/mL. Samples spiked with different concentrations of PSA can be distinguished clearly. Due to the contactless detection method, the detection system exhibited advantages such as convenient manipulation, reusable, inexpensive, small weight. So, this detection method was a promising candidate in biomarker detection, especially in point of care detection.
- 5 July 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (4) , 1-7
Investigation of contactless detection using a giant magnetoresistance sensor for detecting prostate specific antigen
This paper presents a contactless detection method for detecting prostate specific antigen with a giant magnetoresistance sensor. In contactless detection case, the prostate specific antigen sample preparation was separated from the sensor that prevented the sensor from being immersed in chemical solvents, and made the sensor implementing in immediately reuse without wash. Experimental results showed that applied an external magnetic field in a range of 50 Oe to 90 Oe, Dynabeads with a concentration as low as 0.1 μg/mL can be detected by this system and could give an approximate quantitation to the logarithmic of Dynabeads concentration. Sandwich immunoassay was employed for preparing PSA samples. The PSA capture was implemented on a gold film modified with a self-assembled monolayer and using biotinylated secondary antibody against PSA and streptavidinylated Dynabeads. With DC magnetic field in the range of 50 to 90 Oe, PSA can be detected with a detection limit as low as 0.1 ng/mL. Samples spiked with different concentrations of PSA can be distinguished clearly. Due to the contactless detection method, the detection system exhibited advantages such as convenient manipulation, reusable, inexpensive, small weight. So, this detection method was a promising candidate in biomarker detection, especially in point of care detection.
- 2 June 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (8) , 2385-2393
Sandwich immunoassay for the prostate specific antigen using a micro-fluxgate and magnetic bead labels
- 2 June 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (8) , 2385-2393
Sandwich immunoassay for the prostate specific antigen using a micro-fluxgate and magnetic bead labels