Shielding facial physiological information in video
Authors:
Open Access
- 1 January 2022
- journal article
- research article
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 19 (5) , 5153-5168
Abstract
With the recent development of non-contact physiological signal detection methods based on videos, it is possible to obtain the physiological parameters through the ordinary video only, such as heart rate and its variability of an individual. Therefore, personal physiological information may be leaked unknowingly with the spread of videos, which may cause privacy or security problems. In this paper a new method is proposed, which can shield physiological information in the video without reducing the video quality significantly. Firstly, the principle of the most widely used physiological signal detection algorithm: remote photoplethysmography (rPPG) was analyzed. Then the region of interest (ROI) of face contain physiological information with high signal to noise ratio was selected. Two physiological information forgery operation: single-channel periodic noise addition with blur filtering and brightness fine-tuning are conducted on the ROIs. Finally, the processed ROI images are merged into video frames to obtain the processed video. Experiments were performed on the VIPL-HR video dataset. The interference efficiencies of the proposed method on two mainly used rPPG methods: Independent Component Analysis (ICA) and Chrominance-based Method (CHROM) are 82.9 % and 84.6 % respectively, which demonstrated the effectiveness of the proposed method.Keywords
This publication has 21 references indexed in Scilit:
- Bounded Kalman filter method for motion-robust, non-contact heart rate estimationBiomedical Optics Express, 2018
- Deep learning with time-frequency representation for pulse estimation from facial videos2017
- Beyond Face Rotation: Global and Local Perception GAN for Photorealistic and Identity Preserving Frontal View Synthesis2017
- One millisecond face alignment with an ensemble of regression trees2014
- Automatic Face Reenactment2014
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- Making a “Completely Blind” Image Quality AnalyzerIEEE Signal Processing Letters, 2012
- Advancements in Noncontact, Multiparameter Physiological Measurements Using a WebcamIEEE Transactions on Biomedical Engineering, 2010
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004