Individual Modulation of the Tube Current–Seconds to Achieve Similar Levels of Image Noise in Contrast-Enhanced Abdominal CT
Authors:
- Toshiyuki IrieTIToshiyuki Irie
- Hiroaki InoueHIHiroaki Inoue
- 1 May 2005
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 184 (5) , 1514-1518
Abstract
OBJECTIVE. Our aim was to determine the optimal region to measure CT image noise and to evaluate the usefulness of the individual modulation of the tube current–second (milliampere-seconds, or mAs) based on body size to obtain images with similar noise levels. MATERIALS AND METHODS. Contrast-enhanced abdominal CT images obtained by a 4-MDCT scanner were retrospectively analyzed. The image-acquisition factors were fixed (group A, n = 104). The image noise was measured at five regions: the aorta, the back muscle, the spleen, and the peripheral and the central hepatic portions. Body size was evaluated by two methods on the basis of body weight (method A) and on the scout image data (method B). Coefficients of determination of 10 relationships between body size and image noise were calculated. For the next study, CT images were prospectively obtained by modulating the mAs on the basis of body weight (group B, n = 100) and the scout image data (group C, n = 100). We compared the differences in SDs of aortic image noise in each group using the F test. RESULTS. The coefficients of determination of the aorta were 0.619 and 0.812 for methods A and B, respectively, and the highest values in both methods (p = ⅕2, Fisher's exact test). The SDs of the aortic image noise of groups A, B, and C were 2.03, 1.61, and 1.06, respectively. There were statistically significant differences between each group (p < 0.022), and the SD was the smallest in group C. CONCLUSION. The aorta was the optimal region to measure the image noise. Individual mAs modulation based on the scout image data was useful to obtain images of similar noise levels.Keywords
This publication has 23 references indexed in Scilit:
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Detection of Coronary Calcifications: Feasibility of Dose Reduction with a Body Weight–Adapted Examination ProtocolAmerican Journal of Roentgenology, 2003
- Dose Reduction in CT: How Low Can We Go?American Journal of Roentgenology, 2002
- A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation doseBritish Journal of Radiology, 2002
- A rational approach to dose reduction in CT: individualized scan protocolsEuropean Radiology, 2001
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001
- Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CTRadiology, 2000
- Radiation Effective Doses to Patients Undergoing Abdominal CT ExaminationsRadiology, 1999
- An approach for the estimation of effective radiation dose at CT in pediatric patients.Radiology, 1997
- The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies.Radiology, 1981