Latest Publications
- 26 October 2007
- Published by Springer Nature in Radiation Medicine
- Vol. 25 (8) , 411-416
Newly developed application system for CT-guided puncture based on multidetector row CT without CT fluoroscopy
The aim of this article is to describe a preliminary clinical experience with a new multidetector CT (MDCT) system (GuideShot system) for CT-guided intervention. This system enabled simultaneous acquisition and quick display of three axial CT images. Only a single-shot mode was used, with no continuous CT fluoroscopic (CTF) mode. The exposure and the table movement could be controlled by the interventional radiologist using foot pedal switches that are on the floor beside the table. We used this system for biopsy (n = 48), drainage tube placement (n = 7), and hook wire placement prior to video-assisted thoracic surgery (n = 69). Technical success was achieved in all 124 cases. In 123 of 124 cases, each intervention was done within a single breath-hold (99%). The table controller was used in 22 cases (17.7%), and the central portion of the target or the needle tip was easily shifted into the CT collimation after a single table movement. This new system improved Z-axis orientation for the interventional radiologist and enabled rapid interventional procedures without the CTF system. MDCT with this system could be one of the options when single-slice CT with CTF is replaced by MDCT.
- 26 October 2007
- Published by Springer Nature in Radiation Medicine
- Vol. 25 (8) , 411-416
Newly developed application system for CT-guided puncture based on multidetector row CT without CT fluoroscopy
The aim of this article is to describe a preliminary clinical experience with a new multidetector CT (MDCT) system (GuideShot system) for CT-guided intervention. This system enabled simultaneous acquisition and quick display of three axial CT images. Only a single-shot mode was used, with no continuous CT fluoroscopic (CTF) mode. The exposure and the table movement could be controlled by the interventional radiologist using foot pedal switches that are on the floor beside the table. We used this system for biopsy (n = 48), drainage tube placement (n = 7), and hook wire placement prior to video-assisted thoracic surgery (n = 69). Technical success was achieved in all 124 cases. In 123 of 124 cases, each intervention was done within a single breath-hold (99%). The table controller was used in 22 cases (17.7%), and the central portion of the target or the needle tip was easily shifted into the CT collimation after a single table movement. This new system improved Z-axis orientation for the interventional radiologist and enabled rapid interventional procedures without the CTF system. MDCT with this system could be one of the options when single-slice CT with CTF is replaced by MDCT.
- 17 May 2007
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 30 (5) , 901-905
Use of 120 Kilovolt Tube Potential for Digital Subtraction Angiography and Fluoroscopy in an Image-Intensifier Angiographic System: Decrease of Skin Dose in Transarterial Chemoembolization Therapy for Hepatocellular Carcinoma
In an image-intensifier angiographic system, the tube potential is commonly regulated in ranges from 75 to 90 kV for digital subtraction angiography (DSA) and fluoroscopy in transarterial chemoembolization therapy (TACE) for hepatocellular carcinoma. The purpose of this study was to investigate whether or not a 120-kV tube potential could be used for DSA and fluoroscopy in TACE to decrease the skin dose. Forty-three patients administered TACE were randomly allocated into two groups: TACE was performed using standard-kilovoltage (75- to 90-kV) DSA and fluoroscopy modes (group A; n = 20) or using high-kilovoltage (120-kV) modes (group B; n = 23). The peak skin dose was compared between the groups. One case in group A was excluded from the study because the HCC nodule was not depicted on DSA. The peak skin dose (mGy) for group A was 383.6 ± 176.5 and that for group B was 265.1 ± 145.1. The peak skin dose was decreased by 31% in the 120-kV mode, a statistically significant difference (t-test, p = 0.022). We conclude that the use of 120 kV tube potential for DSA and fluoroscopy may be one option for performing TACE while decreasing the skin dose.
- 17 May 2007
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 30 (5) , 901-905
Use of 120 Kilovolt Tube Potential for Digital Subtraction Angiography and Fluoroscopy in an Image-Intensifier Angiographic System: Decrease of Skin Dose in Transarterial Chemoembolization Therapy for Hepatocellular Carcinoma
In an image-intensifier angiographic system, the tube potential is commonly regulated in ranges from 75 to 90 kV for digital subtraction angiography (DSA) and fluoroscopy in transarterial chemoembolization therapy (TACE) for hepatocellular carcinoma. The purpose of this study was to investigate whether or not a 120-kV tube potential could be used for DSA and fluoroscopy in TACE to decrease the skin dose. Forty-three patients administered TACE were randomly allocated into two groups: TACE was performed using standard-kilovoltage (75- to 90-kV) DSA and fluoroscopy modes (group A; n = 20) or using high-kilovoltage (120-kV) modes (group B; n = 23). The peak skin dose was compared between the groups. One case in group A was excluded from the study because the HCC nodule was not depicted on DSA. The peak skin dose (mGy) for group A was 383.6 ± 176.5 and that for group B was 265.1 ± 145.1. The peak skin dose was decreased by 31% in the 120-kV mode, a statistically significant difference (t-test, p = 0.022). We conclude that the use of 120 kV tube potential for DSA and fluoroscopy may be one option for performing TACE while decreasing the skin dose.
- 11 September 2006
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 29 (6) , 986-990
New Embolization Microcoil Consisting of Firm and Flexible Segments: Preliminary Clinical Experience
- 11 September 2006
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 29 (6) , 986-990
New Embolization Microcoil Consisting of Firm and Flexible Segments: Preliminary Clinical Experience
- 1 May 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 184 (5) , 1514-1518
Individual Modulation of the Tube Current–Seconds to Achieve Similar Levels of Image Noise in Contrast-Enhanced Abdominal CT
OBJECTIVE. Our aim was to determine the optimal region to measure CT image noise and to evaluate the usefulness of the individual modulation of the tube current–second (milliampere-seconds, or mAs) based on body size to obtain images with similar noise levels. MATERIALS AND METHODS. Contrast-enhanced abdominal CT images obtained by a 4-MDCT scanner were retrospectively analyzed. The image-acquisition factors were fixed (group A, n = 104). The image noise was measured at five regions: the aorta, the back muscle, the spleen, and the peripheral and the central hepatic portions. Body size was evaluated by two methods on the basis of body weight (method A) and on the scout image data (method B). Coefficients of determination of 10 relationships between body size and image noise were calculated. For the next study, CT images were prospectively obtained by modulating the mAs on the basis of body weight (group B, n = 100) and the scout image data (group C, n = 100). We compared the differences in SDs of aortic image noise in each group using the F test. RESULTS. The coefficients of determination of the aorta were 0.619 and 0.812 for methods A and B, respectively, and the highest values in both methods (p = ⅕2, Fisher's exact test). The SDs of the aortic image noise of groups A, B, and C were 2.03, 1.61, and 1.06, respectively. There were statistically significant differences between each group (p < 0.022), and the SD was the smallest in group C. CONCLUSION. The aorta was the optimal region to measure the image noise. Individual mAs modulation based on the scout image data was useful to obtain images of similar noise levels.
- 1 May 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 184 (5) , 1514-1518
Individual Modulation of the Tube Current–Seconds to Achieve Similar Levels of Image Noise in Contrast-Enhanced Abdominal CT
OBJECTIVE. Our aim was to determine the optimal region to measure CT image noise and to evaluate the usefulness of the individual modulation of the tube current–second (milliampere-seconds, or mAs) based on body size to obtain images with similar noise levels. MATERIALS AND METHODS. Contrast-enhanced abdominal CT images obtained by a 4-MDCT scanner were retrospectively analyzed. The image-acquisition factors were fixed (group A, n = 104). The image noise was measured at five regions: the aorta, the back muscle, the spleen, and the peripheral and the central hepatic portions. Body size was evaluated by two methods on the basis of body weight (method A) and on the scout image data (method B). Coefficients of determination of 10 relationships between body size and image noise were calculated. For the next study, CT images were prospectively obtained by modulating the mAs on the basis of body weight (group B, n = 100) and the scout image data (group C, n = 100). We compared the differences in SDs of aortic image noise in each group using the F test. RESULTS. The coefficients of determination of the aorta were 0.619 and 0.812 for methods A and B, respectively, and the highest values in both methods (p = ⅕2, Fisher's exact test). The SDs of the aortic image noise of groups A, B, and C were 2.03, 1.61, and 1.06, respectively. There were statistically significant differences between each group (p < 0.022), and the SD was the smallest in group C. CONCLUSION. The aorta was the optimal region to measure the image noise. Individual mAs modulation based on the scout image data was useful to obtain images of similar noise levels.
- 1 February 2004
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 15 (2) , 165-168
Realtime Digital Magnification of the Fluoroscopic and Digital Subtraction Angiography Images: Randomized Prospective Study to Show Dose Reduction during Segmental Chemoembolization for Hepatocellular Carcinoma
- 1 February 2004
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 15 (2) , 165-168
Realtime Digital Magnification of the Fluoroscopic and Digital Subtraction Angiography Images: Randomized Prospective Study to Show Dose Reduction during Segmental Chemoembolization for Hepatocellular Carcinoma