Accelerated deep learning-based function assessment in cardiovascular magnetic resonance
Authors:
- Domenico De SantisDSDomenico De Santis
- Luca PuglieseLPLuca Pugliese
- Tiziano PolidoriTPTiziano Polidori
- Curzio SantangeliCSCurzio Santangeli
- Michela PoliciMPMichela Polici
- Antonella Del GaudioAGAntonella Del Gaudio
- Giuseppe TremamunnoGTGiuseppe Tremamunno
- Marta ZerunianMZMarta Zerunian
- Andrea LaghiALAndrea Laghi
- Damiano CarusoDamiano Caruso
Open Access
- 17 May 2025
- journal article
- cardiac radiology
- Published by Springer Nature in La radiologia medica
- Vol. 130 (8) , 1149-1157
Abstract
Purpose: To evaluate diagnostic accuracy and image quality of deep learning (DL) cine sequences for LV and RV parameters compared to conventional balanced steady-state free precession (bSSFP) cine sequences in cardiovascular magnetic resonance (CMR). Material and methods: From January to April 2024, patients with clinically indicated CMR were prospectively included. LV and RV were segmented from short-axis bSSFP and DL cine sequences. LV and RV end-diastolic volume (EDV), end-systolic volume (EDV), stroke volume (SV), ejection fraction, and LV end-diastolic mass were calculated. The acquisition time of both sequences was registered. Results were compared with paired-samples t test or Wilcoxon signed-rank test. Agreement between DL cine and bSSFP was assessed using Bland–Altman plots. Image quality was graded by two readers based on blood-to-myocardium contrast, endocardial edge definition, and motion artifacts, using a 5-point Likert scale (1 = insufficient quality; 5 = excellent quality). Results: Sixty-two patients were included (mean age: 47 ± 17 years, 41 men). No significant differences between DL cine and bSSFP were found for all LV and RV parameters (P ≥ .176). DL cine was significantly faster (1.35 ± .55 m vs 2.83 ± .79 m; P < .001). The agreement between DL cine and bSSFP was strong, with bias ranging from 45 to 1.75% for LV and from − 0.38 to 2.43% for RV. Among LV parameters, the highest agreement was obtained for ESV and SV, which fell within the acceptable limit of agreement (LOA) in 84% of cases. EDV obtained the highest agreement among RV parameters, falling within the acceptable LOA in 90% of cases. Overall image quality was comparable (median: 5, IQR: 4–5; P = .330), while endocardial edge definition of DL cine (median: 4, IQR: 4–5) was lower than bSSFP (median: 5, IQR: 4–5; P = .002). Conclusion: DL cine allows fast and accurate quantification of LV and RV parameters and comparable image quality with conventional bSSFP.Keywords
Funding Information
- Università degli Studi di Roma La Sapienza
This publication has 26 references indexed in Scilit:
- From Compressed‐Sensing to Deep Learning MR: Comparative Biventricular Cardiac Function Analysis in a Patient CohortJournal of Magnetic Resonance Imaging, 2023
- Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult populationThe International Journal of Cardiovascular Imaging, 2023
- AI Based CMR Assessment of Biventricular FunctionJACC: Cardiovascular Imaging, 2022
- Cardiovascular Magnetic Resonance for Patients With COVID-19JACC: Cardiovascular Imaging, 2021
- Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional SequencesJACC: Cardiovascular Imaging, 2021
- MR 4D flow-based mean pulmonary arterial pressure tracking in pulmonary hypertensionEuropean Radiology, 2020
- Accelerating cardiac cine MRI using a deep learning‐based ESPIRiT reconstructionMagnetic Resonance in Medicine, 2020
- On instabilities of deep learning in image reconstruction and the potential costs of AIProceedings of the National Academy of Sciences of the United States of America, 2020
- Diffusion Tensor Cardiovascular Magnetic Resonance ImagingJACC: Cardiovascular Imaging, 2020
- Myocardial Tissue Characterization and Fibrosis by ImagingJACC: Cardiovascular Imaging, 2020