CSCurzio Santangeli

Curzio Santangeli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Curzio Santangeli has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Andrea Laghi

    Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20072 Pieve Emanuele, Milan, Italy; IRCCS Humanitas Research Hospital, Department of Diagnostic Imaging, via Manzoni 56, 20089 Rozzano, Milan, Italy; Department of Surgery, The Netherlands Cancer Institute, Plesmanlaan 121, Amsterdam 1066 CX, the Netherlands

    1 shared publication
  • Antonella Del Gaudio

    Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome, Sant’Andrea Hospital, 00189 Rome, Italy

    1 shared publication
  • Barbara Segulin

    Harefield Hospital, Royal Brompton and Harefield Hospitals, Guy's and St Thomas’ NHS Foundation Trust , Harefield

    1 shared publication
  • Damiano Caruso

    Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome, Sant’Andrea Hospital, 00189 Rome, Italy

    1 shared publication
  • Domenico De Santis

    Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome, Sant’Andrea Hospital, 00189 Rome, Italy

    1 shared publication
  • Federica Fanelli

    Department of Medical-Surgical Sciences and Translational Medicine, School of Medicine and Psychology, Sapienza - University of Rome, Sant’Andrea University Hospital, Rome, Italy

    1 shared publication

Latest Publications

  • Open Access

    Accelerated deep learning-based function assessment in cardiovascular magnetic resonance

    by Domenico De Santis, Federica Fanelli, Luca Pugliese, Giovanna Grazia Bona, Tiziano Polidori, Curzio Santangeli, Michela Polici, Antonella Del Gaudio, Giuseppe Tremamunno, Marta Zerunian, et al.

    Purpose: To evaluate diagnostic accuracy and image quality of deep learning (DL) cine sequences for LV and RV parameters compared to conventional balanced steady-state free precession (bSSFP) cine sequences in cardiovascular magnetic resonance (CMR). Material and methods: From January to April 2024, patients with clinically indicated CMR were prospectively included. LV and RV were segmented from short-axis bSSFP and DL cine sequences. LV and RV end-diastolic volume (EDV), end-systolic volume (EDV), stroke volume (SV), ejection fraction, and LV end-diastolic mass were calculated. The acquisition time of both sequences was registered. Results were compared with paired-samples t test or Wilcoxon signed-rank test. Agreement between DL cine and bSSFP was assessed using Bland–Altman plots. Image quality was graded by two readers based on blood-to-myocardium contrast, endocardial edge definition, and motion artifacts, using a 5-point Likert scale (1 = insufficient quality; 5 = excellent quality). Results: Sixty-two patients were included (mean age: 47 ± 17 years, 41 men). No significant differences between DL cine and bSSFP were found for all LV and RV parameters (P ≥ .176). DL cine was significantly faster (1.35 ± .55 m vs 2.83 ± .79 m; P < .001). The agreement between DL cine and bSSFP was strong, with bias ranging from 45 to 1.75% for LV and from − 0.38 to 2.43% for RV. Among LV parameters, the highest agreement was obtained for ESV and SV, which fell within the acceptable limit of agreement (LOA) in 84% of cases. EDV obtained the highest agreement among RV parameters, falling within the acceptable LOA in 90% of cases. Overall image quality was comparable (median: 5, IQR: 4–5; P = .330), while endocardial edge definition of DL cine (median: 4, IQR: 4–5) was lower than bSSFP (median: 5, IQR: 4–5; P = .002). Conclusion: DL cine allows fast and accurate quantification of LV and RV parameters and comparable image quality with conventional bSSFP.