Off-line motion correction methods for multi-frame PET data
Open Access
- 8 July 2009
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 36 (12) , 2002-2013
Abstract
Purpose Patient motion during PET acquisition may affect measured time-activity curves, thereby reducing accuracy of tracer kinetic analyses. The aim of the present study was to evaluate different off-line frame-by-frame methods to correct patient motion, which is of particular interest when no optical motion tracking system is available or when older data sets have to be reanalysed. Methods Four different motion correction methods were evaluated. In the first method attenuation-corrected frames were realigned with the summed image of the first 3 min. The second method was identical, except that non-attenuation-corrected images were used. In the third and fourth methods non-attenuation-corrected images were realigned with standard and cupped transmission images, respectively. Two simulation studies were performed, based on [11C]flumazenil and (R)-[11C]PK11195 data sets, respectively. For both simulation studies different types (rotational, translational) and degrees of motion were added. Simulated PET scans were corrected for motion using all correction methods. The optimal method derived from these simulation studies was used to evaluate two (one with and one without visible movement) clinical data sets of [11C]flumazenil, (R)-[11C]PK11195 and [11C]PIB. For these clinical data sets, the volume of distribution (VT) was derived using Logan analysis and values were compared before and after motion correction. Results For both [11C]flumazenil and (R)-[11C]PK11195 simulation studies, optimal results were obtained when realignment was based on non-attenuation-corrected images. For the clinical data sets motion disappeared visually after motion correction. Regional differences of up to 433% in VT before and after motion correction were found for scans with visible movement. On the other hand, when no visual motion was present in the original data set, overall differences in VT before and after motion correction were <1.5 ± 1.3%. Conclusion Frame-by-frame motion correction using non-attenuation-corrected images improves the accuracy of tracer kinetic analysis compared to non-motion-corrected data.Keywords
This publication has 19 references indexed in Scilit:
- Image derived input functions for dynamic High Resolution Research Tomograph PET brain studiesNeuroImage, 2008
- Image-derived input functions for PET brain studiesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Partial volume corrected image derived input functions for dynamic PET brain studies: Methodology and validation for [11C]flumazenilNeuroImage, 2008
- Strategies for Motion Tracking and Correction in PETPET Clinics, 2007
- Correction of head movement on PET studies: comparison of methods.2006
- On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies.2005
- Impact of the Spatial Normalization Template and Realignment Procedure on the SPM Analysis of [11C]Raclopride PET StudiesIEEE Transactions on Nuclear Science, 2004
- The design and implementation of a motion correction scheme for neurological PETPhysics in Medicine & Biology, 2003
- A head motion measurement system suitable for emission computed tomographyIEEE Transactions on Medical Imaging, 1997
- Rapid Automated Algorithm for Aligning and Reslicing PET ImagesJournal of Computer Assisted Tomography, 1992