JMJurgen E. M. Mourik

Jurgen E. M. Mourik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jurgen E. M. Mourik has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vivo Validation of Reconstruction-Based Resolution Recovery for Human Brain Studies

    by Jurgen Em Mourik, Mark Lubberink, Floris Hp van Velden, Reina W Kloet, Bart Nm van Berckel, Adriaan A Lammertsma, Ronald Boellaard

    The aim of this study was to validate in vivo the accuracy of a reconstruction-based partial volume correction (PVC), which takes into account the point spread function of the imaging system. The NEMA NU2 Image Quality phantom and five healthy volunteers (using [11C]flumazenil) were scanned on both HR+ and high-resolution research tomograph (HRRT) scanners. HR+ data were reconstructed using normalization and attenuation-weighted ordered subsets expectation maximization (NAW-OSEM) and a PVC algorithm (PVC-NAW-OSEM). HRRT data were reconstructed using 3D ordinary Poisson OSEM (OP-OSEM) and a PVC algorithm (PVC-OP-OSEM). For clinical studies, parametric volume of distribution ( VT) images were generated. For phantom data, good recovery was found for both OP-OSEM (0.84 to 0.97) and PVC-OP-OSEM (0.91 to 0.98) HRRT reconstructions. In addition, for the HR+, good recovery was found for PVC-NAW-OSEM (0.84 to 0.94), corresponding well with OP-OSEM. Finally, for clinical data, good correspondence was found between PVC-NAW-OSEM and OP-OSEM-derived VT values (slope: 1.02±0.08). This study showed that HR+ image resolution using PVC-NAW-OSEM was comparable to that of the HRRT scanner. As the HRRT has a higher intrinsic resolution, this agreement validates reconstruction-based PVC as a means of improving the spatial resolution of the HR+ scanner and thereby improving the quantitative accuracy of positron emission tomography.


  • Open Access

    Off-line motion correction methods for multi-frame PET data

    by Jurgen E. M. Mourik, Mark Lubberink, Floris H. P. van Velden, Adriaan A. Lammertsma, Ronald Boellaard

    Purpose Patient motion during PET acquisition may affect measured time-activity curves, thereby reducing accuracy of tracer kinetic analyses. The aim of the present study was to evaluate different off-line frame-by-frame methods to correct patient motion, which is of particular interest when no optical motion tracking system is available or when older data sets have to be reanalysed. Methods Four different motion correction methods were evaluated. In the first method attenuation-corrected frames were realigned with the summed image of the first 3 min. The second method was identical, except that non-attenuation-corrected images were used. In the third and fourth methods non-attenuation-corrected images were realigned with standard and cupped transmission images, respectively. Two simulation studies were performed, based on [11C]flumazenil and (R)-[11C]PK11195 data sets, respectively. For both simulation studies different types (rotational, translational) and degrees of motion were added. Simulated PET scans were corrected for motion using all correction methods. The optimal method derived from these simulation studies was used to evaluate two (one with and one without visible movement) clinical data sets of [11C]flumazenil, (R)-[11C]PK11195 and [11C]PIB. For these clinical data sets, the volume of distribution (VT) was derived using Logan analysis and values were compared before and after motion correction. Results For both [11C]flumazenil and (R)-[11C]PK11195 simulation studies, optimal results were obtained when realignment was based on non-attenuation-corrected images. For the clinical data sets motion disappeared visually after motion correction. Regional differences of up to 433% in VT before and after motion correction were found for scans with visible movement. On the other hand, when no visual motion was present in the original data set, overall differences in VT before and after motion correction were <1.5 ± 1.3%. Conclusion Frame-by-frame motion correction using non-attenuation-corrected images improves the accuracy of tracer kinetic analysis compared to non-motion-corrected data.


  • Image derived input functions for dynamic High Resolution Research Tomograph PET brain studies

    by Jurgen E.M. Mourik, Floris H.P. van Velden, Mark Lubberink, Reina W. Kloet, Bart N.M. van Berckel, Adriaan A. Lammertsma, Ronald Boellaard


  • Image-derived input functions for PET brain studies

    by Jurgen E. M. Mourik, Mark Lubberink, Alie Schuitemaker, Nelleke Tolboom, Bart N. M. van Berckel, Adriaan A. Lammertsma, Ronald Boellaard

    To assess the robustness of a previously introduced method to obtain accurate image-derived input functions (IDIF) for three other tracers. Dynamic PET and online blood data of five repeat [11C]PIB (Pittsburgh Compound-B) ([11C]PIB), six repeat (R)-[11C]verapamil, and ten single (R)-[11C]PK11195 studies were used. IDIFs were extracted from partial volume corrected scans using the four hottest pixels per plane method. Results obtained with IDIFs were compared with those using standard online measured arterial input functions (BSIF). IDIFs were used both with and without calibration based on manual blood samples. For (R)-[11C]verapamil, accurate IDIFs were obtained using noncalibrated IDIFs (slope 0.96±0.17; R 2 0.92±0.07). However, calibration was necessary to obtain IDIFs comparable to the BSIF for both [11C]PIB (slope 1.04±0.05; R 2 1.00±0.01) and (R)-[11C]PK11195 (slope 0.96±0.05; R 2 0.99±0.01). The need for calibration may be explained by the sticking property of both tracers, indicating that BSIF may be affected by sticking and therefore may be unreliable. The present study shows that a previously proposed method to extract IDIFs is suitable for analysing [11C]PIB, (R)-[11C]verapamil and (R)-[11C]PK11195 studies, thereby obviating the need for online arterial sampling.


  • Partial volume corrected image derived input functions for dynamic PET brain studies: Methodology and validation for [11C]flumazenil

    by Jurgen E.M. Mourik, Mark Lubberink, Ursula M.H. Klumpers, Emile F. Comans, Adriaan A. Lammertsma, Ronald Boellaard