Emer P. Doheny
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Emer P. Doheny has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Madeleine M. Lowery
School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland
7 shared publications - Brian Caulfield
University College Dublin
4 shared publications - Barry. R. Greene
Kinesis Health Technologies Ltd, Dublin, Ireland
3 shared publications - David FitzPatrick
University College Dublin
3 shared publications Clodagh Cunningham
TRIL centre, Dublin, Ireland
2 shared publicationsConor M. Minogue
2 shared publications
Latest Publications
- Open Access
- 31 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2239-2249
Estimation of Gait Parameters in Huntington’s Disease Using Wearable Sensors in the Clinic and Free-living Conditions
In Huntington’s disease (HD), wearable inertial sensors could capture subtle changes in motor function. However, disease-specific validation of methods is necessary. This study presents an algorithm for walking bout and gait event detection in HD using a leg-worn accelerometer, validated only in the clinic and deployed in free-living conditions. Seventeen HD participants wore shank- and thigh-worn tri-axial accelerometers, and a wrist-worn device during two-minute walk tests in the clinic, with video reference data for validation. Thirteen participants wore one of the thigh-worn tri-axial accelerometers (AP: ActivPAL4) and the wrist-worn device for 7 days under free-living conditions, with proprietary AP data used as reference. Gait events were detected from shank and thigh acceleration using the Teager-Kaiser energy operator combined with unsupervised clustering. Estimated step count (SC) and temporal gait parameters were compared with reference data. In the clinic, low mean absolute percentage errors were observed for stride (shank/thigh: 0.6/0.9%) and stance (shank/thigh: 3.3/7.1%) times, and SC (shank/thigh: 3.1%). Similar errors were observed for proprietary AP SC (3.2%), with higher errors observed for the wrist-worn device (10.9%). At home, excellent agreement was observed between the proposed algorithm and AP software for SC and time spent walking (ICC 2,1 >0.975). The wrist-worn device overestimated SC by 34.2%. The presented algorithm additionally allowed stride and stance time estimation, whose variability correlated significantly with clinical motor scores. The results demonstrate a new method for accurate estimation of HD gait parameters in the clinic and free-living conditions, using a single accelerometer worn on either the thigh or shank.
- 31 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2239-2249
Open AccessEstimation of Gait Parameters in Huntington’s Disease Using Wearable Sensors in the Clinic and Free-living Conditions
In Huntington’s disease (HD), wearable inertial sensors could capture subtle changes in motor function. However, disease-specific validation of methods is necessary. This study presents an algorithm for walking bout and gait event detection in HD using a leg-worn accelerometer, validated only in the clinic and deployed in free-living conditions. Seventeen HD participants wore shank- and thigh-worn tri-axial accelerometers, and a wrist-worn device during two-minute walk tests in the clinic, with video reference data for validation. Thirteen participants wore one of the thigh-worn tri-axial accelerometers (AP: ActivPAL4) and the wrist-worn device for 7 days under free-living conditions, with proprietary AP data used as reference. Gait events were detected from shank and thigh acceleration using the Teager-Kaiser energy operator combined with unsupervised clustering. Estimated step count (SC) and temporal gait parameters were compared with reference data. In the clinic, low mean absolute percentage errors were observed for stride (shank/thigh: 0.6/0.9%) and stance (shank/thigh: 3.3/7.1%) times, and SC (shank/thigh: 3.1%). Similar errors were observed for proprietary AP SC (3.2%), with higher errors observed for the wrist-worn device (10.9%). At home, excellent agreement was observed between the proposed algorithm and AP software for SC and time spent walking (ICC 2,1 >0.975). The wrist-worn device overestimated SC by 34.2%. The presented algorithm additionally allowed stride and stance time estimation, whose variability correlated significantly with clinical motor scores. The results demonstrate a new method for accurate estimation of HD gait parameters in the clinic and free-living conditions, using a single accelerometer worn on either the thigh or shank.
- Open Access
- 1 May 2024
- Published by American Speech Language Hearing Association in American Journal of Speech-Language Pathology
- Vol. 33 (3) , 1390-1405
Language-Independent Acoustic Biomarkers for Quantifying Speech Impairment in Huntington's Disease
Purpose: Changes in voice and speech are characteristic symptoms of Huntington's disease (HD). Objective methods for quantifying speech impairment that can be used across languages could facilitate assessment of disease progression and intervention strategies. The aim of this study was to analyze acoustic features to identify language-independent features that could be used to quantify speech dysfunction in English-, Spanish-, and Polish-speaking participants with HD. Method: Ninety participants with HD and 83 control participants performed sustained vowel, syllable repetition, and reading passage tasks recorded with previously validated methods using mobile devices. Language-independent features that differed between HD and controls were identified. Principal component analysis (PCA) and unsupervised clustering were applied to the language-independent features of the HD data set to identify subgroups within the HD data. Results: Forty-six language-independent acoustic features that were significantly different between control participants and participants with HD were identified. Following dimensionality reduction using PCA, four speech clusters were identified in the HD data set. Unified Huntington's Disease Rating Scale (UHDRS) total motor score, total functional capacity, and composite UHDRS were significantly different for pairwise comparisons of subgroups. The percentage of HD participants with higher dysarthria score and disease stage also increased across clusters. Conclusion: The results support the application of acoustic features to objectively quantify speech impairment and disease severity in HD in multilanguage studies. Supplemental Material: https://doi.org/10.23641/asha.25447171
- 1 May 2024
- Published by American Speech Language Hearing Association in American Journal of Speech-Language Pathology
- Vol. 33 (3) , 1390-1405
Open AccessLanguage-Independent Acoustic Biomarkers for Quantifying Speech Impairment in Huntington's Disease
Purpose: Changes in voice and speech are characteristic symptoms of Huntington's disease (HD). Objective methods for quantifying speech impairment that can be used across languages could facilitate assessment of disease progression and intervention strategies. The aim of this study was to analyze acoustic features to identify language-independent features that could be used to quantify speech dysfunction in English-, Spanish-, and Polish-speaking participants with HD. Method: Ninety participants with HD and 83 control participants performed sustained vowel, syllable repetition, and reading passage tasks recorded with previously validated methods using mobile devices. Language-independent features that differed between HD and controls were identified. Principal component analysis (PCA) and unsupervised clustering were applied to the language-independent features of the HD data set to identify subgroups within the HD data. Results: Forty-six language-independent acoustic features that were significantly different between control participants and participants with HD were identified. Following dimensionality reduction using PCA, four speech clusters were identified in the HD data set. Unified Huntington's Disease Rating Scale (UHDRS) total motor score, total functional capacity, and composite UHDRS were significantly different for pairwise comparisons of subgroups. The percentage of HD participants with higher dysarthria score and disease stage also increased across clusters. Conclusion: The results support the application of acoustic features to objectively quantify speech impairment and disease severity in HD in multilanguage studies. Supplemental Material: https://doi.org/10.23641/asha.25447171
- 2 November 2022
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 169, 104911
Prediction of low pulse oxygen saturation in COVID-19 using remote monitoring post hospital discharge
- 2 November 2022
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 169, 104911
Prediction of low pulse oxygen saturation in COVID-19 using remote monitoring post hospital discharge
- Open Access
- 7 June 2022
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 3
Estimating balance, cognitive function, and falls risk using wearable sensors and the sit-to-stand test
The five times sit-to-stand test (FTSS) is an established functional test, used clinically as a measure of lower-limb strength, endurance and falls risk. We report a novel method to estimate and classify cognitive function, balance impairment and falls risk using the FTSS and body-worn inertial sensors. 168 community dwelling older adults received a Comprehensive Geriatric Assessment which included the Mini-Mental State Examination (MMSE) and the Berg Balance Scale (BBS). Each participant performed an FTSS, with inertial sensors on the thigh and torso, either at home or in the clinical environment. Adaptive peak detection was used to identify phases of each FTSS from torso or thigh-mounted inertial sensors. Features were then extracted from each sensor to quantify the timing, postural sway and variability of each FTSS. The relationship between each feature and MMSE and BBS was examined using Spearman’s correlation. Intraclass correlation coefficients were used to examine the intra-session reliability of each feature. A Poisson regression model with an elastic net model selection procedure was used to estimate MMSE and BBS scores, while logistic regression and sequential forward feature selection was used to classify participants according to falls risk, cognitive decline and balance impairment. BBS and MMSE were estimated using cross-validation with low root mean squared errors of 2.91 and 1.50, respectively, while the cross-validated classification accuracies for balance impairment, cognitive decline, and falls risk were 81.96, 72.71, and 68.74%, respectively. The novel methods reported provide surrogate measures which may have utility in remote assessment of physical and cognitive function.
- 7 June 2022
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 3
Open AccessEstimating balance, cognitive function, and falls risk using wearable sensors and the sit-to-stand test
The five times sit-to-stand test (FTSS) is an established functional test, used clinically as a measure of lower-limb strength, endurance and falls risk. We report a novel method to estimate and classify cognitive function, balance impairment and falls risk using the FTSS and body-worn inertial sensors. 168 community dwelling older adults received a Comprehensive Geriatric Assessment which included the Mini-Mental State Examination (MMSE) and the Berg Balance Scale (BBS). Each participant performed an FTSS, with inertial sensors on the thigh and torso, either at home or in the clinical environment. Adaptive peak detection was used to identify phases of each FTSS from torso or thigh-mounted inertial sensors. Features were then extracted from each sensor to quantify the timing, postural sway and variability of each FTSS. The relationship between each feature and MMSE and BBS was examined using Spearman’s correlation. Intraclass correlation coefficients were used to examine the intra-session reliability of each feature. A Poisson regression model with an elastic net model selection procedure was used to estimate MMSE and BBS scores, while logistic regression and sequential forward feature selection was used to classify participants according to falls risk, cognitive decline and balance impairment. BBS and MMSE were estimated using cross-validation with low root mean squared errors of 2.91 and 1.50, respectively, while the cross-validated classification accuracies for balance impairment, cognitive decline, and falls risk were 81.96, 72.71, and 68.74%, respectively. The novel methods reported provide surrogate measures which may have utility in remote assessment of physical and cognitive function.
- 13 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (5) , 2757-2765
Feature-Based Evaluation of a Wearable Surface EMG Sensor Against Laboratory Standard EMG During Force-Varying and Fatiguing Contractions
Recent advances in wearable sensors enable recording of electromyography (EMG) outside the laboratory for extended periods of time. However, the properties of wearable EMG systems designed for long-term recording may differ from those of laboratory-standard systems, potentially impacting data. This study evaluated EMG features derived from signals recorded using a wearable system (BioStampRC, MC10 Inc.) against a reference laboratory system (Bagnoli, Delsys Inc.). Surface EMG data from the biceps brachii were recorded simultaneously using both systems during isometric elbow flexion, between 10 and 80 of maximum voluntary contraction (MVC), and during sustained submaximal fatiguing contraction, in twelve subjects. Linear and nonlinear EMG temporal and spectral features were then compared across both systems. No effect of recording system was detected on EMG onset/offset times, or on the relationship between force and EMG root mean squared amplitude. However, the relationships between force and median frequency, percentage determinism and multiscale entropy differed between systems. Baseline noise was also greater for the BioStampRC. Lower median frequencies were observed for the wearable system, likely due to the larger interelectrode distance, however, the relative change in EMG amplitude and median frequency during the fatiguing contraction was similar for both. Percentage determinism increased and multiscale entropy decreased during the fatiguing contraction for both systems, with higher and lower values respectively for the wearable system. Results indicate that the BiostampRC is appropriate for EMG onset/offset and amplitude estimation. However, caution is advised when comparing across systems as spectral and nonlinear features may differ due to electrode design differences.
- 13 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (5) , 2757-2765
Feature-Based Evaluation of a Wearable Surface EMG Sensor Against Laboratory Standard EMG During Force-Varying and Fatiguing Contractions
Recent advances in wearable sensors enable recording of electromyography (EMG) outside the laboratory for extended periods of time. However, the properties of wearable EMG systems designed for long-term recording may differ from those of laboratory-standard systems, potentially impacting data. This study evaluated EMG features derived from signals recorded using a wearable system (BioStampRC, MC10 Inc.) against a reference laboratory system (Bagnoli, Delsys Inc.). Surface EMG data from the biceps brachii were recorded simultaneously using both systems during isometric elbow flexion, between 10 and 80 of maximum voluntary contraction (MVC), and during sustained submaximal fatiguing contraction, in twelve subjects. Linear and nonlinear EMG temporal and spectral features were then compared across both systems. No effect of recording system was detected on EMG onset/offset times, or on the relationship between force and EMG root mean squared amplitude. However, the relationships between force and median frequency, percentage determinism and multiscale entropy differed between systems. Baseline noise was also greater for the BioStampRC. Lower median frequencies were observed for the wearable system, likely due to the larger interelectrode distance, however, the relative change in EMG amplitude and median frequency during the fatiguing contraction was similar for both. Percentage determinism increased and multiscale entropy decreased during the fatiguing contraction for both systems, with higher and lower values respectively for the wearable system. Results indicate that the BiostampRC is appropriate for EMG onset/offset and amplitude estimation. However, caution is advised when comparing across systems as spectral and nonlinear features may differ due to electrode design differences.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 3300-3303
Displacement of centre of mass during quiet standing assessed using accelerometry in older fallers and non-fallers
Postural sway during quiet standing is associated with falls risk in older adults. The aim of this study was to investigate the utility of a range of accelerometer-derived parameters of centre of mass (COM) displacement in identifying older adults at risk of falling. A series of instrumented standing balance trials were performed to investigate postural control in a group of older adults, categorised as fallers or non-fallers. During each trial, participants were asked to stand as still as possible under two conditions: comfortable stance (six repetitions) and semi-tandem stance (three repetitions). A tri-axial accelerometer was secured to the lower back during the trials. Accelerometer data were twice integrated to estimate COM displacement during the trials, with numerical techniques used to reduce integration error. Anterior-posterior (AP) and medial-lateral (ML) sway range, sway length and sway velocity were examined, along with root mean squared (RMS) acceleration. All derived parameters significantly discriminated fallers from non-fallers during both comfortable and semi-tandem stance. Results indicate that these accelerometer-based estimates of COM displacement may improve the discriminative power of quiet standing falls risk assessments, with potential for use in unsupervised balance assessment.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2012 (1094687X) , 3300-3303
Displacement of centre of mass during quiet standing assessed using accelerometry in older fallers and non-fallers
Postural sway during quiet standing is associated with falls risk in older adults. The aim of this study was to investigate the utility of a range of accelerometer-derived parameters of centre of mass (COM) displacement in identifying older adults at risk of falling. A series of instrumented standing balance trials were performed to investigate postural control in a group of older adults, categorised as fallers or non-fallers. During each trial, participants were asked to stand as still as possible under two conditions: comfortable stance (six repetitions) and semi-tandem stance (three repetitions). A tri-axial accelerometer was secured to the lower back during the trials. Accelerometer data were twice integrated to estimate COM displacement during the trials, with numerical techniques used to reduce integration error. Anterior-posterior (AP) and medial-lateral (ML) sway range, sway length and sway velocity were examined, along with root mean squared (RMS) acceleration. All derived parameters significantly discriminated fallers from non-fallers during both comfortable and semi-tandem stance. Results indicate that these accelerometer-based estimates of COM displacement may improve the discriminative power of quiet standing falls risk assessments, with potential for use in unsupervised balance assessment.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (1094687X) , 3296-3299
Taking balance measurement out of the laboratory and into the home: Discriminatory capability of novel centre of pressure measurement in fallers and non-fallers
We investigated three methods for estimating centre of pressure excursions, as measured using a portable pressure sensor matrix, in order to deploy similar technology into the homes of older adults for longitudinal monitoring of postural control and falls risk. We explored the utility of these three methods as markers of falls risk in a cohort of 120 community dwelling older adults with and without a history of falls (65 fallers, 55 non-fallers). A number of standard quantitative balance parameters were derived using each centre of pressure estimation method. Rank sum tests were used to test for significant differences between fallers and non-fallers while intra-class correlation coefficients were also calculated to determine the reliability of each method. A method based on estimating the changes in the magnitude of pressure exerted on the pressure sensor matrix was found to be the most reliable and discriminative. Our future work will implement this method for home-based balance measurement.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (1094687X) , 3296-3299
Taking balance measurement out of the laboratory and into the home: Discriminatory capability of novel centre of pressure measurement in fallers and non-fallers
We investigated three methods for estimating centre of pressure excursions, as measured using a portable pressure sensor matrix, in order to deploy similar technology into the homes of older adults for longitudinal monitoring of postural control and falls risk. We explored the utility of these three methods as markers of falls risk in a cohort of 120 community dwelling older adults with and without a history of falls (65 fallers, 55 non-fallers). A number of standard quantitative balance parameters were derived using each centre of pressure estimation method. Rank sum tests were used to test for significant differences between fallers and non-fallers while intra-class correlation coefficients were also calculated to determine the reliability of each method. A method based on estimating the changes in the magnitude of pressure exerted on the pressure sensor matrix was found to be the most reliable and discriminative. Our future work will implement this method for home-based balance measurement.
- 22 April 2010
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 32 (5) , 468-474
Effect of subcutaneous fat thickness and surface electrode configuration during neuromuscular electrical stimulation
The effect of subcutaneous fat thickness, electrode size and inter-electrode distance on the minimum stimulus current necessary for fiber excitation was examined in an attempt to improve the efficacy of neuromuscular electrical stimulation (NMES) in obese populations. A three-dimensional finite element model of the human thigh was developed and used to calculate the potential along a myelinated nerve fiber due to NMES. The activating function was used to examine alterations in the excitation of the fiber due to fat thickness, electrode size and inter-electrode distance. The finite element model was coupled to a neural model to examine the stimulus current required for action potential propagation. The stimulus current required to evoke 10% of the maximum M-wave amplitude was measured experimentally. Both experimental and modeling studies indicated that the stimulus current required to reach the threshold for muscle activation increased with fat thickness, electrode size, and inter-electrode distance. However, as fat thickness increased, the threshold for muscle activation became less sensitive to inter-electrode distance and electrode size. These results suggest that by using larger electrodes above regions of high subcutaneous fat thickness, the efficacy of NMES could be maintained while reducing the current density at the skin and the associated subject discomfort.
- 22 April 2010
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 32 (5) , 468-474
Effect of subcutaneous fat thickness and surface electrode configuration during neuromuscular electrical stimulation
The effect of subcutaneous fat thickness, electrode size and inter-electrode distance on the minimum stimulus current necessary for fiber excitation was examined in an attempt to improve the efficacy of neuromuscular electrical stimulation (NMES) in obese populations. A three-dimensional finite element model of the human thigh was developed and used to calculate the potential along a myelinated nerve fiber due to NMES. The activating function was used to examine alterations in the excitation of the fiber due to fat thickness, electrode size and inter-electrode distance. The finite element model was coupled to a neural model to examine the stimulus current required for action potential propagation. The stimulus current required to evoke 10% of the maximum M-wave amplitude was measured experimentally. Both experimental and modeling studies indicated that the stimulus current required to reach the threshold for muscle activation increased with fat thickness, electrode size, and inter-electrode distance. However, as fat thickness increased, the threshold for muscle activation became less sensitive to inter-electrode distance and electrode size. These results suggest that by using larger electrodes above regions of high subcutaneous fat thickness, the efficacy of NMES could be maintained while reducing the current density at the skin and the associated subject discomfort.
- 28 April 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (6) , 589-598
The effect of elbow joint centre displacement on force generation and neural excitation
Joint centre displacement may occur following total elbow replacement due to aseptic loosening or surgical misalignment, and has been linked to implant failure. In this study, the effects of joint centre displacement were examined using a neuromusculoskeletal model of the elbow joint. Isometric contractions were simulated at a range of joint angles during elbow flexion and extension. Displacement of the joint centre affected the force-generating capacity about the joint, due to changes in both muscle lengths and moment arms. The magnitude and direction of the maximum joint reaction force were also altered, potentially contributing to aseptic loosening and compromising joint stability. The relationship between force generated and the level of neural excitation to the elbow flexor and extensor muscles was also affected, suggesting that altered neural control patterns could be required following joint centre displacement.
- 28 April 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (6) , 589-598
The effect of elbow joint centre displacement on force generation and neural excitation
Joint centre displacement may occur following total elbow replacement due to aseptic loosening or surgical misalignment, and has been linked to implant failure. In this study, the effects of joint centre displacement were examined using a neuromusculoskeletal model of the elbow joint. Isometric contractions were simulated at a range of joint angles during elbow flexion and extension. Displacement of the joint centre affected the force-generating capacity about the joint, due to changes in both muscle lengths and moment arms. The magnitude and direction of the maximum joint reaction force were also altered, potentially contributing to aseptic loosening and compromising joint stability. The relationship between force generated and the level of neural excitation to the elbow flexor and extensor muscles was also affected, suggesting that altered neural control patterns could be required following joint centre displacement.