A gas pipeline of Southwest Oil & Gas Field Company was put into operation in 2007. During the MFL in 2010, it was found that there were 408 metal losses, among which 332 internal corrosions were found and imperfects needed to be repaired. There should not have 332 internal corrosions in this pipeline according to the analysis of the internal corroion rate, the clock distribution and one similar pipeline. By considering CO2 corrosion, 66 manufacturing defects deeper than 28% were screened out and 28 imperfects needed to be repaired based on the correction of corrosion rate calculated by de Waard's CO2 corrosion rate empirical formula. The numbers were greatly reduced compared with those before correction. All the internal corrosions were confirmed to be manufacturing defects after excavating and data confirmation. There were 27 defects needed to repaired which was almost the same as the correction by CO2 corrosion rate, thus this method was proved to be valid in correcting the numbers of internal corrosion.