A Comparison between the i-gel® and air-Q® Supraglottic Airway Devices Used for the Patients Undergoing General Anesthesia with Muscle Relaxation
Open Access
- 18 November 2018
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-7
Abstract
Objectives. The aim of the present study was to compare two supraglottic airway (SGA) devices (i.e., the i-gel® © Intersurgical Ltd and air-Q® (Reusable) Cookgas company) in terms of the insertion time, amount of leak during ventilation with maximum positive pressure, and postoperative complications in patients referring to Modarres Hospital in Tehran.Method.The present double-blind clinical trial was performed on 60 patients undergoing elective surgeries that required general anesthesia with muscle relaxation. Patients were randomly assigned to either i-gel® (n= 30) or Air-Q® (n= 30) groups.Results.The mean age, body mass index, duration of surgery, duration of anesthesia, and gender ratio were not significantly different between the two groups. Mean ± SD values of the SGA devices’ insertion time (in seconds) in the air-Q® and i-gel® groups were 4.87 ± 1.6 and 6.80 ± 1.2, respectively (P < 0.001). The mean OLP in the Air-Q® group was significantly higher than that of the i-gel® group (35.9 ± 9.6 versus 24.8 ± 3.7, p < 0.001). The frequency of complications occurred after the supraglottic airway insertion was higher in the i-gel® group. However, only in terms of sore throat, the difference between the two groups was statistically significant: 6 (20%) had sore throat (P = 0.024) in the i-gel groups, but in in the Air-Q® groups no one had this side effect after surgery.Conclusion.It was concluded that the Air-Q® supraglottic airway was placed faster and easier with fewer complications than the i-gel in general anesthesia with muscle relaxation. The frequency of the occurrence of all three complications, cough, sore throat, and blood, on the cuff (6 (20%) was higher in the i-gel group than that in the air-Q® group (cough3 (10%), sore throat 0 (0%), and blood on the cuff 3 (10%) (P < 0.05).Keywords
This publication has 20 references indexed in Scilit:
- Comparison of laryngeal mask airway Supreme and laryngeal mask airway Pro-Seal for controlled ventilation during general anaesthesia in adult patientsEuropean Journal of Anaesthesiology, 2014
- Evaluation of chest compression effect on airway management with air-Q®, aura-i®, i-gel®, and Fastrack® intubating supraglottic devices by novice physicians: a randomized crossover simulation studyJournal of Anesthesia, 2014
- Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tubeIndian Journal of Anaesthesia, 2013
- A randomized trial comparing the Ambu®Aura‐i™ with the air‐Q™ intubating laryngeal airway as conduits for tracheal intubation in childrenPediatric Anesthesia, 2012
- A randomised trial comparing the i‐gel TM with the LMA Classic TM in childrenAnaesthesia, 2012
- LMA Supreme ™ vs i‐gel ™ – a comparison of insertion success in novicesAnaesthesia, 2012
- I-GEL(TM) VS. AURAONCE(TM) LARYNGEAL MASK FOR GENERAL ANAESTHESIA WITH CONTROLLED VENTILATION IN PARALYZED PATIENTSBiomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia, 2011
- Supraglottic airway devices in childrenIndian Journal of Anaesthesia, 2011
- Supraglottic airway devicesBest Practice & Research Clinical Anaesthesiology, 2005
- Optimal intracuff pressures with the laryngeal maskBritish Journal of Anaesthesia, 1996