Sensor location affects skeletal muscle contractility parameters measured by tensiomyography
Open Access
- 9 February 2023
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (2) , e0281651
Abstract
Tensiomyography (TMG) is a non-invasive method for measuring contractile properties of skeletal muscle that is increasingly being used in research and practice. However, the lack of standardization in measurement protocols mitigates the systematic use in sports medical settings. Therefore, this study aimed to investigate the effects of lower leg fixation and sensor location on TMG-derived parameters. Twenty-two male participants underwent TMG measurements on the m. biceps femoris (BF) in randomized order with and without lower leg fixation (fixed vs. non-fixed). Measurements were conducted at 50% of the muscle’s length (BF-mid) and 10 cm distal to this (BF-distal). The sensor location affected the contractile properties significantly, both with and without fixation. Delay time (Td) was greater at BF-mid compared to BF-distal (fixed: 23.2 ± 3.2 ms vs. 21.2 ± 2.7 ms, p = 0.002; non-fixed: 24.03 ± 4.2 ms vs. 21.8 ± 2.7 ms, p = 0.008), as were maximum displacement (Dm) (fixed: 5.3 ± 2.7 mm vs. 3.5 ± 1.7 mm, p = 0.005; non-fixed: 5.4 ± 2.5 mm vs. 4.0 ± 2.0 mm, p = 0.03), and contraction velocity (Vc) (fixed: 76.7 ± 25.1 mm/s vs. 57.2 ± 24.3 mm/s, p = 0.02). No significant differences were revealed for lower leg fixation (all p > 0.05). In summary, sensor location affects the TMG-derived parameters on the BF. Our findings help researchers to create tailored measurement procedures in compliance with the individual goals of the TMG measurements and allow adequate interpretation of TMG parameters.Keywords
This publication has 41 references indexed in Scilit:
- Tensiomyography method used for neuromuscular assessment of muscle trainingJournal of NeuroEngineering and Rehabilitation, 2013
- Tensiomyography of selected lower-limb muscles in professional soccer playersJournal of Electromyography and Kinesiology, 2012
- Between-day reliability of a method for non-invasive estimation of muscle compositionJournal of Electromyography and Kinesiology, 2012
- The effectiveness of two novel techniques in establishing the mechanical and contractile responses of biceps femorisPhysiological Measurement, 2011
- Assessment of muscle fatigue after an ultra-endurance triathlon using tensiomyography (TMG)Journal of Sports Sciences, 2011
- A noninvasive, log-transform method for fiber type discrimination using mechanomyographyJournal of Electromyography and Kinesiology, 2010
- Inter-rater reliability of muscle contractile property measurements using non-invasive tensiomyographyJournal of Electromyography and Kinesiology, 2010
- Whole muscle contractile parameters and thickness loss during 35-day bed restEuropean Journal of Applied Physiology, 2008
- Spatial fiber type distribution in normal human muscleJournal of Biomechanics, 2005
- Evaluation of the ability to make non-invasive estimation of muscle contractile properties on the basis of the muscle belly responseMedical & Biological Engineering & Computing, 2001