GLGeorg Langen

Georg Langen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Georg Langen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The interaction of post-activation potentiation and fatigue on skeletal muscle twitch torque and displacement

    by Georg Langen, Frank Warschun, Olaf Ueberschär, Michael Behringer

    Introduction: Tensiomyography (TMG) assesses skeletal muscle contractile properties based on the electrically stimulated radial muscle displacement. As the relationship between twitch displacement and associated torque is poorly understood, it is unclear how it is affected by post-activation potentiation and muscle fatigue. This study investigated how the interaction of potentiation and fatigue affects the rectus femoris (RF) twitch displacement and associated torque.Materials and methods: Sixteen resistance-trained men (n = 8) and women (n = 8) performed two sets of five and five sets of ten seated maximum voluntary isometric knee extensions to induce potentiation and fatigue. Twitch displacement and torque were measured at baseline before the first set, after each set, and every 2 min for 15 min after the last set.Results: The exercise effectively induced potentiation and fatigue as peak twitch torque increased by 44.1% after the first set, decreased by 32.9% after the last set and remained decreased by 26.4% after 15 min. Twitch displacement was considerably less affected by the exercise. Consequently, TMG parameters could not accurately detect potentiated or fatigued participants as indicated by the peak twitch torque.Discussion: The TMG parameters’ insufficient diagnostic accuracy likely resulted from a reduced signal-to-noise ratio at 90° knee flexion and the associated longer muscle length of the RF, compared to more extended knee angles commonly employed in TMG studies. These results highlight an important methodological consideration as the joint angle, i.e. muscle length, appears to influence the TMG parameters’ ability to detect exercise-induced changes in contractile properties.


  • Open Access

    Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A registered report

    by Georg Langen, Christine Lohr, Olaf Ueberschär, Michael Behringer

    Background: Tensiomyography measures the radial displacement of a muscle during an electrically evoked twitch contraction. Different concepts to determine the rate of displacement (Vc) from the maximum twitch exist, but information on their reproducibility is scarce. Further, different inter-stimuli intervals during progressive stimulation are used, but the effect of different intervals on Vc is unclear. Objectives: The first aim of this study was to investigate the within and between-day reliability of the five most frequently used Vc concepts. The second aim was to investigate the effect of different inter-stimuli intervals on Vc. Methods: On two consecutive days, we determined Vc of the biceps femoris long head and rectus femoris of twenty-four healthy subjects. The maximum displacement was determined twice within three minutes on day one and a third time 24 h later. Also, on day two, we applied three blocks of ten consecutive stimuli at a constant intensity of 50 mA, separated by 3 min each. Inter-stimuli intervals in randomly ordered blocks were 10 s, 20 s or 30 s, respectively. Results: All Vc concepts displayed good to excellent relative (ICC 0.87–0.99) and generally good absolute within- and between-day reliability for both muscles. Across Vc-concepts, absolute reliability was higher for the rectus femoris (CV% 1.3–7.95%) compared to the biceps femoris (CV% 6.06–15.30%). In both muscles, Vc was generally not affected by different inter-stimuli intervals. For most Vc concepts, repeated stimulation induced an increase regardless of the inter-stimuli interval, but this effect was mainly trivial and small at most. Conclusions: The reproducibility of Vc concepts was generally good but varies between different muscles. A rest interval of 10 s seems preferable to longer intervals for less time required per measurement. Following this initial study, the effect of different inter-stimuli intervals on Vc should be further investigated.


  • Open Access

    Sensor location affects skeletal muscle contractility parameters measured by tensiomyography

    by Carsten Schwiete, Christian Roth, Christoph Braun, Lukas Rettenmaier, Kevin Happ, Georg Langen, Michael Behringer

    Tensiomyography (TMG) is a non-invasive method for measuring contractile properties of skeletal muscle that is increasingly being used in research and practice. However, the lack of standardization in measurement protocols mitigates the systematic use in sports medical settings. Therefore, this study aimed to investigate the effects of lower leg fixation and sensor location on TMG-derived parameters. Twenty-two male participants underwent TMG measurements on the m. biceps femoris (BF) in randomized order with and without lower leg fixation (fixed vs. non-fixed). Measurements were conducted at 50% of the muscle’s length (BF-mid) and 10 cm distal to this (BF-distal). The sensor location affected the contractile properties significantly, both with and without fixation. Delay time (Td) was greater at BF-mid compared to BF-distal (fixed: 23.2 ± 3.2 ms vs. 21.2 ± 2.7 ms, p = 0.002; non-fixed: 24.03 ± 4.2 ms vs. 21.8 ± 2.7 ms, p = 0.008), as were maximum displacement (Dm) (fixed: 5.3 ± 2.7 mm vs. 3.5 ± 1.7 mm, p = 0.005; non-fixed: 5.4 ± 2.5 mm vs. 4.0 ± 2.0 mm, p = 0.03), and contraction velocity (Vc) (fixed: 76.7 ± 25.1 mm/s vs. 57.2 ± 24.3 mm/s, p = 0.02). No significant differences were revealed for lower leg fixation (all p > 0.05). In summary, sensor location affects the TMG-derived parameters on the BF. Our findings help researchers to create tailored measurement procedures in compliance with the individual goals of the TMG measurements and allow adequate interpretation of TMG parameters.


  • Open Access

    Reporting and transparent research practices in sports medicine and orthopaedic clinical trials: a meta-research study

    by Robert Schulz, Georg Langen, Robert Prill, Michael Cassel, Tracey L Weissgerber

    Objectives Transparent reporting of clinical trials is essential to assess the risk of bias and translate research findings into clinical practice. While existing studies have shown that deficiencies are common, detailed empirical and field-specific data are scarce. Therefore, this study aimed to examine current clinical trial reporting and transparent research practices in sports medicine and orthopaedics. Setting Exploratory meta-research study on reporting quality and transparent research practices in orthopaedics and sports medicine clinical trials. Participants The sample included clinical trials published in the top 25% of sports medicine and orthopaedics journals over 9 months. Primary and secondary outcome measures Two independent reviewers assessed pre-registration, open data and criteria related to scientific rigour, like randomisation, blinding, and sample size calculations, as well as the study sample, and data analysis. Results The sample included 163 clinical trials from 27 journals. While the majority of trials mentioned rigour criteria, essential details were often missing. Sixty per cent (95% confidence interval (CI) 53% to 68%) of trials reported sample size calculations, but only 32% (95% CI 25% to 39%) justified the expected effect size. Few trials indicated the blinding status of all main stakeholders (4%; 95% CI 1% to 7%). Only 18% (95% CI 12% to 24%) included information on randomisation type, method and concealed allocation. Most trials reported participants’ sex/gender (95%; 95% CI 92% to 98%) and information on inclusion and exclusion criteria (78%; 95% CI 72% to 84%). Only 20% (95% CI 14% to 26%) of trials were pre-registered. No trials deposited data in open repositories. Conclusions These results will aid the sports medicine and orthopaedics community in developing tailored interventions to improve reporting. While authors typically mention blinding, randomisation and other factors, essential details are often missing. Greater acceptance of open science practices, like pre-registration and open data, is needed. As these practices have been widely encouraged, we discuss systemic interventions that may improve clinical trial reporting.


  • Open Access

    Reproducibility of knee extensor and flexor contraction velocity in healthy men and women assessed using tensiomyography: A study protocol

    by Georg Langen, Christine Lohr, Olaf Ueberschär, Michael Behringer

    Tensiomyography measures the radial displacement of a muscle during an electrically evoked twitch contraction. The rate of muscle displacement is increasingly reported to assess contractile properties. Several formulas currently exist to calculate the rate of displacement during the contraction phase of the maximal twitch response. However, information on the reproducibility of these formulas is scarce. Further, different rest intervals ranging from 10 s to 30 s are applied between consecutive stimuli during progressive electrical stimulation until the maximum twitch response. The effect of different rest intervals on the rate of displacement has not been investigated so far. The first aim of this study is to investigate the within and between-day reliability of the most frequently used formulas to calculate the rate of displacement. The second aim is to investigate the effect of changing the inter-stimulus interval on the rate of displacement. We will determine the rectus femoris and biceps femoris rate of displacement of twenty-four healthy subjects’ dominant leg on two consecutive days. The maximum displacement curve will be determined two times within three minutes on the first day and a third time 24 h later. On day two, we will also apply three blocks of ten consecutive stimuli at a constant intensity of 50 mA. Inter-stimuli intervals will be 10 s, 20 s or 30 s in each block, respectively, and three minutes between blocks. The order of inter-stimulus intervals will be randomized. This study will allow a direct comparison between the five most frequently used formulas to calculate the rate of displacement in terms of their reproducibility. Our data will also inform on the effect of different inter-stimulus intervals on the rate of displacement. These results will provide helpful information on methodical considerations to determine the rate of displacement and may thus contribute to a standardized approach.


  • Open Access

    The devil is in the details: Reporting and transparent research practices in sports medicine and orthopedic clinical trials

    by Robert Schulz, Georg Langen, Robert Prill, Michael Cassel, Tracey Weissgerber

    Introduction While transparent reporting of clinical trials is essential to assess the risk of bias and translate research findings into clinical practice, earlier studies have shown that deficiencies are common. This study examined current clinical trial reporting and transparent research practices in sports medicine and orthopedics. Methods The sample included clinical trials published in the top 25% of sports medicine and orthopedics journals over eight months. Two independent reviewers assessed pre-registration, open data and criteria related to scientific rigor, the study sample, and data analysis. Results The sample included 163 clinical trials from 27 journals. While the majority of trials mentioned rigor criteria, essential details were often missing. Sixty percent (confidence interval [CI] 53-68%) of trials reported sample size calculations, but only 32% (CI 25-39%) justified the expected effect size. Few trials indicated the blinding status of all main stakeholders (4%; CI 1-7%). Only 18% (CI 12-24%) included information on randomization type, method, and concealed allocation. Most trials reported participants’ sex/gender (95%; CI 92-98%) and information on inclusion and exclusion criteria (78%; CI 72-84%). Only 20% (CI 14-26%) of trials were pre-registered. No trials deposited data in open repositories. Conclusions These results will aid the sports medicine and orthopedics community in developing tailored interventions to improve reporting. While authors typically mention blinding, randomization and other factors, essential details are often missing. Greater acceptance of open science practices, like pre-registration and open data, is needed. These practices have been widely encouraged, we discuss systemic interventions that may improve clinical trial reporting. Registration https://doi.org/10.17605/OSF.IO/9648H