Quality of cardiopulmonary resuscitation on manikins: on the floor and in the bed
Authors:
- 2 September 2009
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 53 (9) , 1131-1137
Abstract
Background: In general, in‐hospital resuscitation is performed in a bed and out‐of‐hospital resuscitation on the floor. The surface under the patient may affect the cardiopulmonary resuscitation (CPR) quality; therefore, we evaluated CPR quality (the percentage of chest compressions of correct depth) and rescuer's fatigue (the mean compression depth minute by minute) when CPR is performed on a manikin on the floor or in the bed.Methods: Forty‐four simulated cardiac arrest scenarios of 10 min were treated by intensive care unit (ICU) nurses in pairs using a 30 : 2 chest compression‐to‐ventilation ratio. The rescuer who performed the compressions was changed every 2 min. CPR was randomly performed either on the floor or in the bed without a backboard; in both settings, participants kneeled beside the manikin.Results: A total number of 1060 chest compressions, 44% with correct depth, were performed on the floor; 1068 chest compressions were performed in the bed, and 58% of these were the correct depth. These differences were not significant between groups. The mean compression depth during the scenario was 44.9±6.2 mm (mean±SD) on the floor and 43.0±5.9 mm in the bed (P=0.3). The mean chest compression depth decreased over time on both surfaces (PP=0.305).Conclusions: ICU nurses perform chest compression as effectively on the floor as in the bed. The mean chest compression depth decreases over time, but the surface had no significant effect.Keywords
This publication has 21 references indexed in Scilit:
- Effects of rescuer position on the kinematics of cardiopulmonary resuscitation (CPR) and the force of delivered compressionsResuscitation, 2008
- The effect on quality of chest compressions and exhaustion of a compression–ventilation ratio of 30:2 versus 15:2 during cardiopulmonary resuscitation—A randomised trialResuscitation, 2007
- Increasing compression depth during manikin CPR using a simple backboardActa Anaesthesiologica Scandinavica, 2007
- Compression force–depth relationship during out-of-hospital cardiopulmonary resuscitationResuscitation, 2007
- Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrestResuscitation, 2006
- European Resuscitation Council Guidelines for Resuscitation 2005Resuscitation, 2005
- Factors influencing survival after in-hospital cardiopulmonary resuscitationResuscitation, 2005
- Compression characteristics of CPR manikinsResuscitation, 1995
- Decay in Quality of Closed-Chest Compressions Over TimeAnnals of Emergency Medicine, 1995
- Coronary blood flow during cardiopulmonary resuscitation in swine.Circulation, 1984