Multiple PM Low-Cost Sensors, Multiple Seasons’ Data, and Multiple Calibration Models
Authors:
- Srishti SSSSrishti S
- Vakacherla SreekanthVSVakacherla Sreekanth
Open Access
- 1 January 2023
- journal article
- research article
- Published by Springer Nature in Aerosol and Air Quality Research
- Vol. 23 (3) , 220428
Abstract
In this study, we combined state-of-the-art data analysis techniques (machine learning [ML] methods) and data from state-of-the-art low-cost particulate matter (PM) sensors (LCSs) to improve the accuracy of LCS-measured PM2.5 (PM with aerodynamic diameter less than 2.5 microns) mass concentrations. We collocated nine LCSs and a reference PM2.5 instrument for 9 months, covering all local seasons, in Bengaluru, India. Using the collocation data, we evaluated the performance of the LCSs and trained around 170 ML models to reduce the observed bias in the LCS-measured PM2.5. The ML models included (i) Decision Tree, (ii) Random Forest (RF), (iii) eXtreme Gradient Boosting, and (iv) Support Vector Regression (SVR). A hold-out validation was performed to assess the model performance. Model performance metrics included (i) coefficient of determination (R2), (ii) root mean square error (RMSE), (iii) normalised RMSE, and (iv) mean absolute error. We found that the bias in the LCS PM2.5 measurements varied across different LCS types (RMSE = 9–30 µg m-3) and that SVR models performed best in correcting the LCS PM2.5 measurements. Hyperparameter tuning improved the performance of the ML models (except for RF). The performance of ML models trained with significant predictors (fewer in number than the number of all predictors, chosen based on recursive feature elimination algorithm) was comparable to that of the ‘all predictors’ trained models (except for RF). The performance of most ML models was better than that of the linear models. Finally, as a research objective, we introduced the collocated black carbon mass concentration measurements into the ML models but found no significant improvement in the model performance.Keywords
This publication has 26 references indexed in Scilit:
- Bias in PM2.5 measurements using collocated reference-grade and optical instrumentsEnvironmental Monitoring and Assessment, 2022
- Characteristics and health risk assessment of fine particulate matter and surface ozone: results from Bengaluru, IndiaEnvironmental Monitoring and Assessment, 2022
- Evaluation of nine machine learning regression algorithms for calibration of low-cost PM2.5 sensorJournal of Aerosol Science, 2021
- Calibrating low-cost sensors for ambient air monitoring: Techniques, trends, and challengesEnvironmental Research, 2021
- Improving accuracy of air pollution exposure measurements: Statistical correction of a municipal low-cost airborne particulate matter sensor networkEnvironmental Pollution, 2021
- Laboratory evaluation of low-cost PurpleAir PM monitors and in-field correction using co-located portable filter samplersAtmospheric Environment, 2020
- Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring siteAtmospheric Environment, 2019
- Examination of monitoring approaches for ambient air pollution: A case study for IndiaAtmospheric Environment, 2019
- Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone?Environment International, 2018
- The rise of low-cost sensing for managing air pollution in citiesEnvironment International, 2015