Multi‐parametric T2* magnetic resonance fingerprinting using variable echo times
Authors:
- 16 July 2018
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (9) , e3951
Abstract
The use of quantitative imaging biomarkers in the imaging of various disease states, including cancer and neurodegenerative disease, has increased in recent years. T1, T2, and T2* relaxation time constants have been shown to be affected by tissue structure or contrast infusion. Acquiring these biomarkers simultaneously in a multi‐parametric acquisition could provide more robust detection of tissue changes in various disease states including neurodegeneration and cancer. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T1 and T2 relaxation time constants. In this study, T2* relaxation is added to the MRF framework using variable echo times (TE).To demonstrate the feasibility of the method and compare incremental and golden angle spiral rotations, simulated phantom data was fit using the proposed method. Additionally, T1/T2/T2*/δf MRF as well as conventional T1, T2, and T2* acquisitions were acquired in agar phantoms and the brains of three healthy volunteers.Golden angle spiral rotation was found to reduce inaccuracy resulting from off resonance effects. Strong correlations were found between conventional and MRF values in the T1, T2, and T2* relaxation time constants of the agar phantoms and healthy volunteers.In this study, T2* relaxation has been incorporated into the MRF framework by using variable echo times, while still fitting for T1 and T2 relaxation time constants. In addition to fitting these relaxation time constants, a novel method for fitting and correcting off resonance effects has been developed.Keywords
Funding Information
- Division of Cancer Prevention, National Cancer Institute (P30-CA069533)
- National Institute of General Medical Sciences (S10 OD018224S10 OD021701S10 RR027694)
- V Foundation for Cancer Research (Translation Research Grant)
This publication has 50 references indexed in Scilit:
- Susceptibility-Weighted Imaging is More Reliable Than T2*-Weighted Gradient-Recalled Echo MRI for Detecting MicrobleedsStroke, 2013
- Cerebral blood volume MRI with intravascular superparamagnetic iron oxide nanoparticlesNMR in Biomedicine, 2012
- Estimating T1 from multichannel variable flip angle SPGR sequencesMagnetic Resonance in Medicine, 2012
- Brain Iron Deposition and Sequence Characteristics in ParkinsonismInvestigative Radiology, 2010
- A robust methodology for in vivo T1 mappingMagnetic Resonance in Medicine, 2010
- Estimation of k‐space trajectories in spiral MRIMagnetic Resonance in Medicine, 2009
- Hyperthermia MRI temperature measurement: Evaluation of measurement stabilisation strategies for extremity and breast tumoursInternational Journal of Hyperthermia, 2009
- Block regional off-resonance correction (BRORC): A fast and effective deblurring method for spiral imagingMagnetic Resonance in Medicine, 2003
- A homogeneity correction method for magnetic resonance imaging with time-varying gradientsIEEE Transactions on Medical Imaging, 1991
- Lung cancer: tissue characterization by magnetic resonance imaging T 1, and T 2 values in vitro and role of histopathologyBritish Journal of Radiology, 1989