Cory R. Wyatt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cory R. Wyatt has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Alexander R. Guimaraes
Department of Diagnostic Radiology Oregon Health & Science University Portland Oregon USA
4 shared publications- Alexander Ramos Guimarães
Brenden-Colson Center for Pancreatic Care, Knight Cancer Institute (OHSU), OR, Portland
1 shared publication Brett Sheppard
Department of Medicine, Division of Gastrointestinal and General Surgery Oregon Health & Science University Portland Oregon USA
1 shared publication- Christina U. Lorentz
Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR
1 shared publication - David Gailani
Department of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
1 shared publication - Deepak Kumar
Department of Physical Therapy, Boston University, Boston, MA, USA
1 shared publication
Latest Publications
- 10 February 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (6) , 1662-1672
T 1 ρ Magnetic Resonance Fingerprinting in Patients With Chronic Pancreatitis
Background: Noninvasive detection of chronic pancreatitis (CP) is important for proper treatment and prevention of severe pain and pancreatic insufficiency. Purpose: To evaluate if T 1 ρ MRF is significantly different in healthy volunteers and patients with CP. Study Type: Prospective. Population: Seventeen healthy volunteers (9 male, mean age: 38.0 ± 6.7 years) and 20 patients (12 male, mean age: 53.6 ± 6.4 years) who were clinically diagnosed with CP. Field Strength/Sequence: 3 T, T 1 ρ MRF acquired during breath‐hold (BH‐MRF) and free breathing (FB‐MRF), conventional T 1 /T 2 mapping sequences. Assessment: Mean T 1 /T 2 /T 1 ρ values in the whole pancreas were compared between diagnosed CP patients and controls. The Cambridge classification (CC) score was used to divide patients into mild–moderate (CC = 1–3) and severe (CC = 4) CP subgroups. T 1 , T 2 , and T 1 ρ relaxation maps were generated from both breath‐hold (BH) and free‐breathing (FB) MRF data. Statistical Tests: Mixed effects models were calculated for healthy control versus CP, and between mild–moderate and severe CP. Receiver operator characteristic (ROC) curves were analyzed and areas under the curves (AUCs) were calculated. A p ‐value < 0.05 was considered significant and multiple comparison corrections were applied. Results: BH‐MRF T 1 /T 2 /T 1 ρ values were significantly higher in the CP group (1327.3, 48.6, 49.1 ms) compared to healthy controls (821.6, 41.6, 39.5 ms) with AUCs of 0.994, 0.873, and 0.862, respectively. The MRF BH T 1 /T 2 /T 1 ρ values of mild–moderate CP ( N = 7) and severe CP ( N = 13) patients were also significantly higher compared to healthy controls. T 1 was significantly higher in severe CP compared to mild–moderate CP (1497 and 1012.1 ms, respectively) with AUC = 0.945. FB MRF T 1 relaxation times demonstrated good correlation with BH values (0.981), while T 2 and T 1 ρ had moderate correlations (0.507 and 0.697, respectively). Data Conclusions: T 1 , T 2 , and T 1 ρ relaxation times have potential for noninvasively assessing CP. Evidence Level: 2. Technical Efficacy: Stage 2.
- 10 February 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (6) , 1662-1672
T 1 ρ Magnetic Resonance Fingerprinting in Patients With Chronic Pancreatitis
Background: Noninvasive detection of chronic pancreatitis (CP) is important for proper treatment and prevention of severe pain and pancreatic insufficiency. Purpose: To evaluate if T 1 ρ MRF is significantly different in healthy volunteers and patients with CP. Study Type: Prospective. Population: Seventeen healthy volunteers (9 male, mean age: 38.0 ± 6.7 years) and 20 patients (12 male, mean age: 53.6 ± 6.4 years) who were clinically diagnosed with CP. Field Strength/Sequence: 3 T, T 1 ρ MRF acquired during breath‐hold (BH‐MRF) and free breathing (FB‐MRF), conventional T 1 /T 2 mapping sequences. Assessment: Mean T 1 /T 2 /T 1 ρ values in the whole pancreas were compared between diagnosed CP patients and controls. The Cambridge classification (CC) score was used to divide patients into mild–moderate (CC = 1–3) and severe (CC = 4) CP subgroups. T 1 , T 2 , and T 1 ρ relaxation maps were generated from both breath‐hold (BH) and free‐breathing (FB) MRF data. Statistical Tests: Mixed effects models were calculated for healthy control versus CP, and between mild–moderate and severe CP. Receiver operator characteristic (ROC) curves were analyzed and areas under the curves (AUCs) were calculated. A p ‐value < 0.05 was considered significant and multiple comparison corrections were applied. Results: BH‐MRF T 1 /T 2 /T 1 ρ values were significantly higher in the CP group (1327.3, 48.6, 49.1 ms) compared to healthy controls (821.6, 41.6, 39.5 ms) with AUCs of 0.994, 0.873, and 0.862, respectively. The MRF BH T 1 /T 2 /T 1 ρ values of mild–moderate CP ( N = 7) and severe CP ( N = 13) patients were also significantly higher compared to healthy controls. T 1 was significantly higher in severe CP compared to mild–moderate CP (1497 and 1012.1 ms, respectively) with AUC = 0.945. FB MRF T 1 relaxation times demonstrated good correlation with BH values (0.981), while T 2 and T 1 ρ had moderate correlations (0.507 and 0.697, respectively). Data Conclusions: T 1 , T 2 , and T 1 ρ relaxation times have potential for noninvasively assessing CP. Evidence Level: 2. Technical Efficacy: Stage 2.
- 12 July 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (5) , 1481-1482
Editorial for “Preoperative Multifrequency MR Elastography for Stratifying Wnt/β‐Catenin Pathway and Microvascular Invasion Phenotypes in Hepatocellular Carcinoma”
- 12 July 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (5) , 1481-1482
Editorial for “Preoperative Multifrequency MR Elastography for Stratifying Wnt/β‐Catenin Pathway and Microvascular Invasion Phenotypes in Hepatocellular Carcinoma”
- 30 December 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (1) , 174-175
Editorial for “Simultaneous Bilateral T1, T2, and T1ρ Relaxation Mapping of Hip Joint With 3D‐MRI Fingerprinting”
- 30 December 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (1) , 174-175
Editorial for “Simultaneous Bilateral T1, T2, and T1ρ Relaxation Mapping of Hip Joint With 3D‐MRI Fingerprinting”
- 1 February 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (4) , 1676-1677
Editorial for “Evaluate the Microvascular Invasion of Hepatocellular Carcinoma (≤5 cm) and Recurrence Free Survival with Gadoxetate Disodium–Enhanced MRI‐Based Habitat Imaging”
- 1 February 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (4) , 1676-1677
Editorial for “Evaluate the Microvascular Invasion of Hepatocellular Carcinoma (≤5 cm) and Recurrence Free Survival with Gadoxetate Disodium–Enhanced MRI‐Based Habitat Imaging”
- 20 March 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (6) , 1750-1751
Editorial for “Deep Learning‐Based Segmentation of Locally Advanced Breast Cancer on MRI in Relation to Residual Cancer Burden: A Multi‐Institutional Cohort Study”
- 20 March 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (6) , 1750-1751
Editorial for “Deep Learning‐Based Segmentation of Locally Advanced Breast Cancer on MRI in Relation to Residual Cancer Burden: A Multi‐Institutional Cohort Study”
- 24 March 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (1) , 151-163
3D MR fingerprinting using Seiffert spirals
Purpose: Seiffert spirals were recently explored as an efficient way to traverse 3D k‐space compared to traditional 3D techniques. Several studies have shown the ability of 3D MR fingerprinting (MRF) techniques to acquire T1 and T2 relaxation maps in a short period of time. However, these sequences do not sample across a large region of 3D k‐space every TR, especially in the way that Seiffert trajectories can.Methods: A 3D MRF sequence was designed using 8 Seiffert spirals rotated in 3D k‐space, with flip angle modulation for T1 and T2 sensitivity. The sequence was compared to an MRF sequence using a 2D spiral rotated in 3D k‐space using the tiny golden angle acquisition with similar resolution/readout duration. Both sequences were evaluated using simulations, phantom validation, and in vivo imaging.Results: In all experiments, the Seiffert spiral MRF sequence performed similar to if not better than the multi‐axis 2D spiral MRF sequence. Strong intraclass correlation coefficients (> 0.9) were found between conventional and MRF sequences in phantoms, whereas the in vivo results showed slightly less aliasing artifact with the Seiffert trajectory.Conclusion: In this study, Seiffert spirals were used within the MRF framework to acquire high‐resolution T1 and T2 relaxation time maps in less than 2.5 min. The reduced aliasing artifacts seen with the Seiffert sequence suggests that sampling over 3D k‐space evenly each TR can improve quantification or shorten scan times.
- 24 March 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (1) , 151-163
3D MR fingerprinting using Seiffert spirals
Purpose: Seiffert spirals were recently explored as an efficient way to traverse 3D k‐space compared to traditional 3D techniques. Several studies have shown the ability of 3D MR fingerprinting (MRF) techniques to acquire T1 and T2 relaxation maps in a short period of time. However, these sequences do not sample across a large region of 3D k‐space every TR, especially in the way that Seiffert trajectories can.Methods: A 3D MRF sequence was designed using 8 Seiffert spirals rotated in 3D k‐space, with flip angle modulation for T1 and T2 sensitivity. The sequence was compared to an MRF sequence using a 2D spiral rotated in 3D k‐space using the tiny golden angle acquisition with similar resolution/readout duration. Both sequences were evaluated using simulations, phantom validation, and in vivo imaging.Results: In all experiments, the Seiffert spiral MRF sequence performed similar to if not better than the multi‐axis 2D spiral MRF sequence. Strong intraclass correlation coefficients (> 0.9) were found between conventional and MRF sequences in phantoms, whereas the in vivo results showed slightly less aliasing artifact with the Seiffert trajectory.Conclusion: In this study, Seiffert spirals were used within the MRF framework to acquire high‐resolution T1 and T2 relaxation time maps in less than 2.5 min. The reduced aliasing artifacts seen with the Seiffert sequence suggests that sampling over 3D k‐space evenly each TR can improve quantification or shorten scan times.
- 22 July 2021
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (2) , 528-529
Editorial for “Noninvasive Evaluation of Renal Hypoxia by Multiparametric Functional MRI in Early Diabetic Kidney Disease”
- 22 July 2021
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 55 (2) , 528-529
Editorial for “Noninvasive Evaluation of Renal Hypoxia by Multiparametric Functional MRI in Early Diabetic Kidney Disease”
- 3 March 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (5) , e4284
T1ρ magnetic resonance fingerprinting
T1ρ relaxation imaging is a quantitative imaging technique that has been used to assess cartilage integrity, liver fibrosis, tumors, cardiac infarction, and Alzheimer's disease. T1, T2, and T1ρ relaxation time constants have each demonstrated different degrees of sensitivity to several markers of fibrosis and inflammation, allowing for a potential multi‐parametric approach to tissue quantification. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T1 and T2 relaxation time constants. In this study, T1ρ relaxation is added to the MRF framework using spin lock preparations. An MRF sequence involving an RF‐spoiled sequence with TR, flip angle, T1ρ, and T2 preparation variation is described. The sequence is then calibrated against conventional T1, T2, and T1ρ relaxation mapping techniques in agar phantoms and the abdomens of four healthy volunteers. Strong intraclass correlation coefficients (ICC > 0.9) were found between conventional and MRF sequences in phantoms and also in healthy volunteers (ICC > 0.8). The highest ICC correlation values were seen in T1, followed by T1ρ and then T2. In this study, T1ρ relaxation has been incorporated into the MRF framework by using spin lock preparations, while still fitting for T1 and T2 relaxation time constants. The acquisition of these parameters within a single breath hold in the abdomen alleviates the issues of movement between breath holds in conventional techniques.
- 3 March 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (5) , e4284
T1ρ magnetic resonance fingerprinting
T1ρ relaxation imaging is a quantitative imaging technique that has been used to assess cartilage integrity, liver fibrosis, tumors, cardiac infarction, and Alzheimer's disease. T1, T2, and T1ρ relaxation time constants have each demonstrated different degrees of sensitivity to several markers of fibrosis and inflammation, allowing for a potential multi‐parametric approach to tissue quantification. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T1 and T2 relaxation time constants. In this study, T1ρ relaxation is added to the MRF framework using spin lock preparations. An MRF sequence involving an RF‐spoiled sequence with TR, flip angle, T1ρ, and T2 preparation variation is described. The sequence is then calibrated against conventional T1, T2, and T1ρ relaxation mapping techniques in agar phantoms and the abdomens of four healthy volunteers. Strong intraclass correlation coefficients (ICC > 0.9) were found between conventional and MRF sequences in phantoms and also in healthy volunteers (ICC > 0.8). The highest ICC correlation values were seen in T1, followed by T1ρ and then T2. In this study, T1ρ relaxation has been incorporated into the MRF framework by using spin lock preparations, while still fitting for T1 and T2 relaxation time constants. The acquisition of these parameters within a single breath hold in the abdomen alleviates the issues of movement between breath holds in conventional techniques.
- 16 July 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (9) , e3951
Multi‐parametric T2* magnetic resonance fingerprinting using variable echo times
The use of quantitative imaging biomarkers in the imaging of various disease states, including cancer and neurodegenerative disease, has increased in recent years. T1, T2, and T2* relaxation time constants have been shown to be affected by tissue structure or contrast infusion. Acquiring these biomarkers simultaneously in a multi‐parametric acquisition could provide more robust detection of tissue changes in various disease states including neurodegeneration and cancer. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T1 and T2 relaxation time constants. In this study, T2* relaxation is added to the MRF framework using variable echo times (TE).To demonstrate the feasibility of the method and compare incremental and golden angle spiral rotations, simulated phantom data was fit using the proposed method. Additionally, T1/T2/T2*/δf MRF as well as conventional T1, T2, and T2* acquisitions were acquired in agar phantoms and the brains of three healthy volunteers.Golden angle spiral rotation was found to reduce inaccuracy resulting from off resonance effects. Strong correlations were found between conventional and MRF values in the T1, T2, and T2* relaxation time constants of the agar phantoms and healthy volunteers.In this study, T2* relaxation has been incorporated into the MRF framework by using variable echo times, while still fitting for T1 and T2 relaxation time constants. In addition to fitting these relaxation time constants, a novel method for fitting and correcting off resonance effects has been developed.
- 16 July 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (9) , e3951
Multi‐parametric T2* magnetic resonance fingerprinting using variable echo times
The use of quantitative imaging biomarkers in the imaging of various disease states, including cancer and neurodegenerative disease, has increased in recent years. T1, T2, and T2* relaxation time constants have been shown to be affected by tissue structure or contrast infusion. Acquiring these biomarkers simultaneously in a multi‐parametric acquisition could provide more robust detection of tissue changes in various disease states including neurodegeneration and cancer. Traditional magnetic resonance fingerprinting (MRF) has been shown to provide quick, quantitative mapping of T1 and T2 relaxation time constants. In this study, T2* relaxation is added to the MRF framework using variable echo times (TE).To demonstrate the feasibility of the method and compare incremental and golden angle spiral rotations, simulated phantom data was fit using the proposed method. Additionally, T1/T2/T2*/δf MRF as well as conventional T1, T2, and T2* acquisitions were acquired in agar phantoms and the brains of three healthy volunteers.Golden angle spiral rotation was found to reduce inaccuracy resulting from off resonance effects. Strong correlations were found between conventional and MRF values in the T1, T2, and T2* relaxation time constants of the agar phantoms and healthy volunteers.In this study, T2* relaxation has been incorporated into the MRF framework by using variable echo times, while still fitting for T1 and T2 relaxation time constants. In addition to fitting these relaxation time constants, a novel method for fitting and correcting off resonance effects has been developed.