Structural Analysis of Aspiration Catheters and Procedural Outcomes: An Analysis of the SVIN Registry
Authors:
Open Access
- 1 July 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke: Vascular and Interventional Neurology
- Vol. 4 (4)
Abstract
Background: Rapid expansion of mechanical thrombectomy and swift manufacturing development has translated into significant evolution of large‐bore catheter technology. The objective of this study was to evaluate the association among diverse structural components of large‐bore aspiration catheters on procedural performance. Methods: Retrospective analysis of a prospectively maintained mechanical thrombectomy consortium (SVIN [Society of Vascular Interventional Neurology] Registry) treated with stand‐alone contact aspiration for the first pass in the middle cerebral artery M1 or intracranial internal carotid artery occlusions from 2012 to 2021. Catheters were stratified on the basis of construction materials, tip technology, catheter sizing, and catheter lining. Factors associated with first‐pass effect (first‐pass eTICI 2c–3 reperfusion) as well as speed of clot engagement were analyzed. Results: We identified 983 patients with proximal occlusion and aspiration as the first‐pass technique. First‐pass effect was observed in 34% and associated with age (odds ratio [OR], 1.02 [95% CI, 1.01–1.03]), cardioembolic stroke pathogenesis (OR, 1.69 [95% CI, 1.77–2.41]), middle cerebral artery M1 (OR, 2.74 [95% CI, 1.09–1.87]), nongeneral anesthesia (OR, 0.55 [95% CI, 0.39–0.767]), as well as with 0.070‐inch (OR, 2.04 95% CI, 1.01–3.78]), and 0.088‐inch (OR, 3.90 [95% CI, 1.58–9.61]) distal catheter inner diameter in the adjusted analysis. Mean time from arterial access to clot contact was 17 minutes, with faster times observed in younger patients (OR, 0.99 [95% CI, 0.98–0.996]) as well as with the use of aspiration catheters with shorter length of distal outer hydrophilic coating (18–30 cm) on multivariable regression (OR, 0.30 [95% CI, 0.11–0.82]). Conclusion: Larger aspiration catheter distal inner diameter was associated with higher rates of first‐pass effect. Aspiration catheter construction components were found to influence times from arterial access to clot contact.Keywords
This publication has 35 references indexed in Scilit:
- First-Pass Effect in M1-Occlusion Stroke Patients Treated with Combined Stent-Retriever/Large-Bore Distal Aspiration Catheter ThrombectomyClinical Neuroradiology, 2023
- Aspiration thrombectomy versus stent retriever thrombectomy as first-line approach for large vessel occlusion (COMPASS): a multicentre, randomised, open label, blinded outcome, non-inferiority trialThe Lancet, 2019
- Effect of Endovascular Contact Aspiration vs Stent Retriever on Revascularization in Patients With Acute Ischemic Stroke and Large Vessel OcclusionJAMA, 2017
- Mechanical thrombectomy after intravenous alteplase versus alteplase alone after stroke (THRACE): a randomised controlled trialThe Lancet Neurology, 2016
- Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trialsThe Lancet, 2016
- Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in StrokeNew England Journal of Medicine, 2015
- Randomized Assessment of Rapid Endovascular Treatment of Ischemic StrokeNew England Journal of Medicine, 2015
- Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging SelectionNew England Journal of Medicine, 2015
- A Randomized Trial of Intraarterial Treatment for Acute Ischemic StrokeNew England Journal of Medicine, 2015
- Large tube section is the key to successful coronary thrombus aspiration: Findings of a standardized bench testCatheterization and Cardiovascular Interventions, 2005