Future easy and physiological cardiac pacing
Open Access
- 1 January 2011
- journal article
- Published by Baishideng Publishing Group Inc. in World Journal of Cardiology
- Vol. 3 (1) , 32-9
Abstract
The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacing seems not to be able to prevent atrial fibrillation in DDD pacing for tachycardia-bradycardia syndrome, and the presence of a left bundle branch type of activation induced by RVA pacing can have negative effects. A new technology with active screw-in leads permits a more physiological atrial and right ventricular pacing. In this review, we highlight the positive effects of pacing of these new and easily selected sites. The septal atrial lead permits a shorter and more homogeneous atrial activation, allowing better prevention of paroxysmal atrial fibrillation. The para-Hisian pacing can be achieved in a simpler and more reliable way with respect to biventricular pacing and direct Hisian pacing. We await larger trials to consider this "easy and physiological pacing" as a first approach in patients who need a high frequency of pacing.Keywords
This publication has 44 references indexed in Scilit:
- Biventricular Pacing in Patients with Bradycardia and Normal Ejection FractionNew England Journal of Medicine, 2009
- Is Bifocal Right Ventricular Pacing a Viable Form of Cardiac Resynchronization?Pacing and Clinical Electrophysiology, 2008
- Excitation of the Intrinsic Conduction System Through His and Interventricular Septal PacingPacing and Clinical Electrophysiology, 2006
- A Feasible Approach for Direct His‐Bundle Pacing Using a New Steerable Catheter to Facilitate Precise Lead PlacementJournal of Cardiovascular Electrophysiology, 2006
- Characteristics of Bifocal Pacing:Pacing and Clinical Electrophysiology, 2005
- A randomized comparison ofatrial and dual-chamber pacing in177 consecutive patients with sick sinus syndromeJACC, 2003
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- Comparison of acute changes in left ventricular volume, systolic and diastolic functions, and intraventricular synchronicity after biventricular and right ventricular pacing for heart failureAmerican Heart Journal, 2003
- Prevention of recurrent atrial fibrillation with chronic dual-site right atrial pacingJACC, 1996
- Influence of cardiac pacing mode on the long-term development of atrial fibrillationThe American Journal of Cardiology, 1989