Eraldo Occhetta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eraldo Occhetta has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Gabriella Francalacci
Clinica Cardiologica A.O.U. Maggiore della Carità, Novara, Italy
4 shared publications- Andrea Magnani
Department of Cardiology, University Hospital 'Maggiore della Carità', Novara, Italy
3 shared publications Laura Plebani
Clinica Cardiologica A.O.U. Maggiore della Carità, Novara, Italy
3 shared publicationsPaolo Marino
3 shared publicationsAndrea Magnani
Department of Cardiology, University Hospital 'Maggiore della Carità', Corso Mazzini 18, 28100 Novara, Italy
2 shared publicationsChiara Cavallino
2 shared publications
Latest Publications
- Open Access
- 1 March 2017
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 17 (2) , 29-33
Persistence of ICD indication at the time of replacement in patients with initial implant for primary prevention indication: Effect on subsequent ICD therapies
- 1 March 2017
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 17 (2) , 29-33
Open AccessPersistence of ICD indication at the time of replacement in patients with initial implant for primary prevention indication: Effect on subsequent ICD therapies
- 2 December 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (4) , 596-601
Occurrence of simultaneous cathodal–anodal capture with left ventricular quadripolar leads for cardiac resynchronization therapy: an electrocardiogram evaluation
The occurrence of left ventricular (LV) anodal activation during pacing with modern multipolar cardiac resynchronization therapy (CRT) systems has never been reported. The aim of our study was to demonstrate, by means of electrocardiogram (ECG) analysis, the occurrence of simultaneous cathodal–anodal LV capture with quadripolar LV leads. We studied 10 first-time recipients of a CRT device equipped with a quadripolar LV lead. During follow-up, standard supine 12-lead ECGs were obtained in available cathode-to-anode LV pacing configurations with a pulse amplitude equal to twice the pacing threshold. The occurrence of simultaneous cathodal–anodal LV capture was defined as the presence of variations in electrocardiographic ventricular activation (EVA) when the distal tip (cathode)-to-device can (anode) pacing configuration was compared with the distal tip (cathode)-to-proximal ring (anode) configuration. In eight patients, we found differences in EVA when different LV sites were paced through the unipolar LV tip and unipolar LV ring configurations. In these patients, a difference in EVA was detected in 61.5% (59 of 96) of the ECG leads (marked difference in 31.3%, slight difference in 30.2%). Changes in EVA between unipolar tip-to-can and bipolar tip-to-ring pacing that were suggestive of cathodal–anodal LV capture were found in six patients. In these patients, a total of 30 (41.7%) ECG leads showed a difference in EVA (marked difference in 20.8%, slight difference in 20.8%). In our experience, additional anodal capture by the proximal LV ring during LV pacing is provable in most recipients of a resynchronization device equipped with a multipolar LV lead.
- 2 December 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (4) , 596-601
Occurrence of simultaneous cathodal–anodal capture with left ventricular quadripolar leads for cardiac resynchronization therapy: an electrocardiogram evaluation
The occurrence of left ventricular (LV) anodal activation during pacing with modern multipolar cardiac resynchronization therapy (CRT) systems has never been reported. The aim of our study was to demonstrate, by means of electrocardiogram (ECG) analysis, the occurrence of simultaneous cathodal–anodal LV capture with quadripolar LV leads. We studied 10 first-time recipients of a CRT device equipped with a quadripolar LV lead. During follow-up, standard supine 12-lead ECGs were obtained in available cathode-to-anode LV pacing configurations with a pulse amplitude equal to twice the pacing threshold. The occurrence of simultaneous cathodal–anodal LV capture was defined as the presence of variations in electrocardiographic ventricular activation (EVA) when the distal tip (cathode)-to-device can (anode) pacing configuration was compared with the distal tip (cathode)-to-proximal ring (anode) configuration. In eight patients, we found differences in EVA when different LV sites were paced through the unipolar LV tip and unipolar LV ring configurations. In these patients, a difference in EVA was detected in 61.5% (59 of 96) of the ECG leads (marked difference in 31.3%, slight difference in 30.2%). Changes in EVA between unipolar tip-to-can and bipolar tip-to-ring pacing that were suggestive of cathodal–anodal LV capture were found in six patients. In these patients, a total of 30 (41.7%) ECG leads showed a difference in EVA (marked difference in 20.8%, slight difference in 20.8%). In our experience, additional anodal capture by the proximal LV ring during LV pacing is provable in most recipients of a resynchronization device equipped with a multipolar LV lead.
- Open Access
- 1 January 2015
- Published by Baishideng Publishing Group Inc. in World Journal of Cardiology
- Vol. 7 (8) , 490-498
Right ventricular septal pacing: Safety and efficacy in a long term follow up
Right ventricular septal pacing: Safety and efficacy in a long term follow up
- 1 January 2015
- Published by Baishideng Publishing Group Inc. in World Journal of Cardiology
- Vol. 7 (8) , 490-498
Open AccessRight ventricular septal pacing: Safety and efficacy in a long term follow up
Right ventricular septal pacing: Safety and efficacy in a long term follow up
- Open Access
- 1 January 2011
- Published by Baishideng Publishing Group Inc. in World Journal of Cardiology
- Vol. 3 (1) , 32-9
Future easy and physiological cardiac pacing
The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacing seems not to be able to prevent atrial fibrillation in DDD pacing for tachycardia-bradycardia syndrome, and the presence of a left bundle branch type of activation induced by RVA pacing can have negative effects. A new technology with active screw-in leads permits a more physiological atrial and right ventricular pacing. In this review, we highlight the positive effects of pacing of these new and easily selected sites. The septal atrial lead permits a shorter and more homogeneous atrial activation, allowing better prevention of paroxysmal atrial fibrillation. The para-Hisian pacing can be achieved in a simpler and more reliable way with respect to biventricular pacing and direct Hisian pacing. We await larger trials to consider this "easy and physiological pacing" as a first approach in patients who need a high frequency of pacing.
- 1 January 2011
- Published by Baishideng Publishing Group Inc. in World Journal of Cardiology
- Vol. 3 (1) , 32-9
Open AccessFuture easy and physiological cardiac pacing
The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacing seems not to be able to prevent atrial fibrillation in DDD pacing for tachycardia-bradycardia syndrome, and the presence of a left bundle branch type of activation induced by RVA pacing can have negative effects. A new technology with active screw-in leads permits a more physiological atrial and right ventricular pacing. In this review, we highlight the positive effects of pacing of these new and easily selected sites. The septal atrial lead permits a shorter and more homogeneous atrial activation, allowing better prevention of paroxysmal atrial fibrillation. The para-Hisian pacing can be achieved in a simpler and more reliable way with respect to biventricular pacing and direct Hisian pacing. We await larger trials to consider this "easy and physiological pacing" as a first approach in patients who need a high frequency of pacing.
- 1 October 2006
- Vol. 7 (10) , 695-701
[Electrical storms in patients with implantable cardioverter-defibrillator: incidence and clinical management].
Electrical storm in implantable cardioverter-defibrillator (ICD) recipients is a dramatic experience for the patient and a hard emergency for the cardiology team. The aim of our study was to evaluate the incidence and the clinical significance of electrical storm in a standard population of ICD patients. We considered retrospectively 262 consecutive ICD patients (86% males, mean age 65+/-10.7 years). Patients were divided into three groups: 88 patients without appropriate ICD therapy (group A); 140 patients with isolated ICD therapies (group B); 34 patients with electrical storm episodes (> or = 3 appropriate ICD therapies/24 h) (group C). Survival study (endpoint death) was performed for each group of patients. There was no difference in age, sex, heart disease, ejection fraction or NYHA functional class among the three groups. ICD implant was performed for secondary prevention in 79% of group C patients and in 74.3 % of group B patients, but only in 39.8 % of group A patients (p < 0.0001). Mean follow-up was 31.1+/-29.8 months in group A, 55.1+/-38 months in group B, and 71.1+/-51.7 months in group C. The endpoint was reached by 16 patients (18%) of group A, by 53 patients (38%) of group B, and by 20 patients (58%) of group C. Comparison of the survival curves of the three groups did not show significant differences. In group C patients, 54 electrical storm episodes were recorded (mean 1.5/patient). In our population of ICD patients, we observed electrical storm in 34 patients (12.9%). Survival in group with episodes of electrical storm was comparable to patients without electrical storm; thus, in our experience, electrical storm could not represent a negative prognostic factor.
- 1 October 2006
- Vol. 7 (10) , 695-701
[Electrical storms in patients with implantable cardioverter-defibrillator: incidence and clinical management].
Electrical storm in implantable cardioverter-defibrillator (ICD) recipients is a dramatic experience for the patient and a hard emergency for the cardiology team. The aim of our study was to evaluate the incidence and the clinical significance of electrical storm in a standard population of ICD patients. We considered retrospectively 262 consecutive ICD patients (86% males, mean age 65+/-10.7 years). Patients were divided into three groups: 88 patients without appropriate ICD therapy (group A); 140 patients with isolated ICD therapies (group B); 34 patients with electrical storm episodes (> or = 3 appropriate ICD therapies/24 h) (group C). Survival study (endpoint death) was performed for each group of patients. There was no difference in age, sex, heart disease, ejection fraction or NYHA functional class among the three groups. ICD implant was performed for secondary prevention in 79% of group C patients and in 74.3 % of group B patients, but only in 39.8 % of group A patients (p < 0.0001). Mean follow-up was 31.1+/-29.8 months in group A, 55.1+/-38 months in group B, and 71.1+/-51.7 months in group C. The endpoint was reached by 16 patients (18%) of group A, by 53 patients (38%) of group B, and by 20 patients (58%) of group C. Comparison of the survival curves of the three groups did not show significant differences. In group C patients, 54 electrical storm episodes were recorded (mean 1.5/patient). In our population of ICD patients, we observed electrical storm in 34 patients (12.9%). Survival in group with episodes of electrical storm was comparable to patients without electrical storm; thus, in our experience, electrical storm could not represent a negative prognostic factor.
- 1 November 1991
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1828-1834
A New Approach to the Prevention of Endless Loop Tachycardia in DDD and VVD Pacing
- 1 November 1991
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1828-1834
A New Approach to the Prevention of Endless Loop Tachycardia in DDD and VVD Pacing