Evaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis
Open Access
- 1 January 2023
- journal article
- research article
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 67 (2) , 196-205
Abstract
Purpose: We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis. Methods: Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.0 mm width) and minor connector (1.5 mm thickness, 6.0 mm height), and rest seat models with mechanical properties of enamel were constructed. The radius of transitional curvature between the rest and minor connector was 0.1-0.5 mm. The rest and rest seat model interfaces were set as frictional contacts (μ = 0.1), and the base of the rest seat model was restrained in all the directions. A 100 N downward load was applied perpendicular to the bottom surface of the minor connector. The maximum value of the first principal stress (Max-S1) was compared to the flexural and fatigue strengths of each material. Occlusal rests with 1.0-2.0 mm thickness, 2.0-3.5 mm width, and 0.5 mm radius of transitional curvature were analyzed. Results: Max-S1 was observed at the transitional part and decreased with increasing radius of the transitional curvature, rest width, and thickness. PEEK rests with at least 1.5 mm thicknesses and 3.0 mm widths showed lower Max-S1 than the flexural strength. Max-S1 of all PEEK rests exceeded the PEEK fatigue strength, whereas Max-S1 of the zirconia rests was lower than the zirconia fatigue strength. Conclusion: Zirconia occlusal rests with conventional metal rest designs have sufficient fatigue strength. PEEK occlusal rests have insufficient fatigue strength and may not withstand repeated mastication.Keywords
This publication has 40 references indexed in Scilit:
- Three-dimensional finite element analysis of molars with thin-walled prosthetic crowns made of various materialsDental Materials, 2012
- Fatigue life prediction of dentin–adhesive interface using micromechanical stress analysisDental Materials, 2011
- Tooth preparation for rest seats for cobalt-chromium removable partial dentures completed by general dental practitionersJournal of Oral Rehabilitation, 2010
- Finite Element Based Fatigue Life Prediction of Cylinder Head for Two-Stroke Linear Engine Using Stress-Life ApproachJournal of Applied Sciences, 2008
- An overview of zirconia ceramics: Basic properties and clinical applicationsJournal of Dentistry, 2007
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Static, dynamic and fatigue behaviors of dental implant using finite element methodAdvances in Engineering Software, 2006
- Fatigue resistance of cast occlusal rests using Co-Cr and Ag-Pd-Cu-Au alloysThe Journal of Prosthetic Dentistry, 2003
- Rehabilitation of biting abilities in patients with different types of dental prosthesesJournal of Oral Rehabilitation, 2000
- Bite force and its correlations in different denture typesActa Odontologica Scandinavica, 1985