Natsuko Murakami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Natsuko Murakami has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Noriyuki Wakabayashi
Advanced Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan
11 shared publications- Noriyuki Wakabayashi
Professor, Department of Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan
8 shared publications Toshiki Yamazaki
Advanced Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan
7 shared publicationsHidekazu Takahashi
Course of Oral Health Engineering, School of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University (TMDU)
4 shared publications- Junichiro Wada
Department of Advanced Prosthodontics, Institute of Science Tokyo, Tokyo, Japan
4 shared publications Hitomi Matsuno
Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Institution of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan
3 shared publications
Latest Publications
- 2 June 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (3) , 615-624
Nasal function in patients with maxillectomy using various obturator designs
- 2 June 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (3) , 615-624
Nasal function in patients with maxillectomy using various obturator designs
- 4 February 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 165, 106928
Effects of tensile and compressive stress on bone resorption and formation parameters surrounding dental implants
- 4 February 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 165, 106928
Effects of tensile and compressive stress on bone resorption and formation parameters surrounding dental implants
- Open Access
Evaluation of Fitting Accuracy of Light- and Auto-Polymerizing Reline Materials Using Three-Dimensional Measurement Techniques
Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner®, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III®, Tokuyama, AP) were used. The gaps formed between the relined denture base and the simplified edentulous model were evaluated. The displacement and deviation of the experimentally relined RPDs on the partially edentulous models were analyzed using 3D data superimposition. In the edentulous model, the gaps at all measurement points were significantly smaller for the AP than in the LP. Moreover, the alveolar ridge crest gap was significantly larger than that at other sites. In the partial denture model, the RMS values at the residual ridge crest were significantly lower for the AP. The evaluation method using 3D scanning and comparison was suitable for a detailed fit analysis. Further improvements in the scanning accuracy may enhance future assessments. Therefore, the evaluation method using 3D scanning and comparison was suitable for effectively analyzing the fit of relines, necessitating further accuracy improvements.
Open AccessEvaluation of Fitting Accuracy of Light- and Auto-Polymerizing Reline Materials Using Three-Dimensional Measurement Techniques
Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner®, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III®, Tokuyama, AP) were used. The gaps formed between the relined denture base and the simplified edentulous model were evaluated. The displacement and deviation of the experimentally relined RPDs on the partially edentulous models were analyzed using 3D data superimposition. In the edentulous model, the gaps at all measurement points were significantly smaller for the AP than in the LP. Moreover, the alveolar ridge crest gap was significantly larger than that at other sites. In the partial denture model, the RMS values at the residual ridge crest were significantly lower for the AP. The evaluation method using 3D scanning and comparison was suitable for a detailed fit analysis. Further improvements in the scanning accuracy may enhance future assessments. Therefore, the evaluation method using 3D scanning and comparison was suitable for effectively analyzing the fit of relines, necessitating further accuracy improvements.
- Open Access
- 1 January 2025
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 69 (4) , 509-518
Thermal stress behavior of monolithic zirconia crowns with different thicknesses
Purpose: This study was aimed at investigating the thermal stresses in monolithic zirconia crowns (MZC) of various thicknesses and elucidating their thermal behavior under cooling or heating changes in the oral cavity. Additionally, the clinical availability and potential issues of MZC were examined by comparing them with other crown materials.Methods: Finite element models comprising MZC (0.5-, 1.0-, and 1.5-mm thick), cement layers, and abutment teeth were subjected to thermal changes from 37 to 5 °C or 60 °C. Using a thermal distribution at 5 s, the thermal stress was calculated and compared with those of gold alloy and resin composite crowns. The loads corresponding to the thermal stresses were also estimated by comparing them with the stresses induced by vertical loading on the occlusal surface.Results: Tensile stress occurred primarily in the crowns and cement during cooling, whereas compressive stress was generated during heating. Thermal stresses increased from 16.0 to 27.2 MPa with decreasing crown thickness from 1.5 to 0.5 mm and varied with different materials. Although the MZC exhibited the highest thermal stress, the estimated load (200 N) corresponding to the thermal stress was smaller than that of the resin composite (1280 N).Conclusions: Thinner crowns exhibited higher thermal stress, suggesting an increased risk of failure owing to thermal changes. Despite the higher thermal stress in thinner MZC, the stresses were below the fatigue strength of the material, indicating sufficient resistance to thermal changes in the oral cavity.
- 1 January 2025
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 69 (4) , 509-518
Open AccessThermal stress behavior of monolithic zirconia crowns with different thicknesses
Purpose: This study was aimed at investigating the thermal stresses in monolithic zirconia crowns (MZC) of various thicknesses and elucidating their thermal behavior under cooling or heating changes in the oral cavity. Additionally, the clinical availability and potential issues of MZC were examined by comparing them with other crown materials.Methods: Finite element models comprising MZC (0.5-, 1.0-, and 1.5-mm thick), cement layers, and abutment teeth were subjected to thermal changes from 37 to 5 °C or 60 °C. Using a thermal distribution at 5 s, the thermal stress was calculated and compared with those of gold alloy and resin composite crowns. The loads corresponding to the thermal stresses were also estimated by comparing them with the stresses induced by vertical loading on the occlusal surface.Results: Tensile stress occurred primarily in the crowns and cement during cooling, whereas compressive stress was generated during heating. Thermal stresses increased from 16.0 to 27.2 MPa with decreasing crown thickness from 1.5 to 0.5 mm and varied with different materials. Although the MZC exhibited the highest thermal stress, the estimated load (200 N) corresponding to the thermal stress was smaller than that of the resin composite (1280 N).Conclusions: Thinner crowns exhibited higher thermal stress, suggesting an increased risk of failure owing to thermal changes. Despite the higher thermal stress in thinner MZC, the stresses were below the fatigue strength of the material, indicating sufficient resistance to thermal changes in the oral cavity.
- Open Access
- 15 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7103
Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman’s ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression.
- 15 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7103
Open AccessMorphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study
Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman’s ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression.
- Open Access
- 25 May 2023
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 42 (3) , 336-342
Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments
This study aimed to evaluate the retentive force of polyetheretherketone (PEEK) and zirconia secondary crowns on ready-made titanium implant abutments (with height, diameter, and taper as 5.5 mm, 4.5 mm, and 6°, respectively) as the primary crown. PEEK, zirconia, and titanium secondary crowns were fabricated using a CAD/CAM system. Insertion and removal tests of secondary crowns on the primary crown were conducted for 2,000 cycles. The initial retentive forces recorded at the 100th cycle for PEEK, zirconia, and titanium were 13.0±7.9, 2.9±2.6, and 27.6±1.7 N, respectively. The retentive forces of PEEK and zirconia showed no significant difference among all cycles. However, the retentive force of the titanium used as a control decreased (20.3±2.8 N) significantly at the 2,000th cycle. Although the retentive force of PEEK was lower than that of titanium, it was within the range that can provide a suitable retentive force of 5 N for removable dental prostheses.
- 25 May 2023
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 42 (3) , 336-342
Open AccessRetentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments
This study aimed to evaluate the retentive force of polyetheretherketone (PEEK) and zirconia secondary crowns on ready-made titanium implant abutments (with height, diameter, and taper as 5.5 mm, 4.5 mm, and 6°, respectively) as the primary crown. PEEK, zirconia, and titanium secondary crowns were fabricated using a CAD/CAM system. Insertion and removal tests of secondary crowns on the primary crown were conducted for 2,000 cycles. The initial retentive forces recorded at the 100th cycle for PEEK, zirconia, and titanium were 13.0±7.9, 2.9±2.6, and 27.6±1.7 N, respectively. The retentive forces of PEEK and zirconia showed no significant difference among all cycles. However, the retentive force of the titanium used as a control decreased (20.3±2.8 N) significantly at the 2,000th cycle. Although the retentive force of PEEK was lower than that of titanium, it was within the range that can provide a suitable retentive force of 5 N for removable dental prostheses.
- 6 January 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105666
Effect of tension and compression on dynamic alveolar histomorphometry
- 6 January 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105666
Effect of tension and compression on dynamic alveolar histomorphometry
- Open Access
- 1 January 2023
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 67 (2) , 196-205
Evaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis
Purpose: We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis. Methods: Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.0 mm width) and minor connector (1.5 mm thickness, 6.0 mm height), and rest seat models with mechanical properties of enamel were constructed. The radius of transitional curvature between the rest and minor connector was 0.1-0.5 mm. The rest and rest seat model interfaces were set as frictional contacts (μ = 0.1), and the base of the rest seat model was restrained in all the directions. A 100 N downward load was applied perpendicular to the bottom surface of the minor connector. The maximum value of the first principal stress (Max-S1) was compared to the flexural and fatigue strengths of each material. Occlusal rests with 1.0-2.0 mm thickness, 2.0-3.5 mm width, and 0.5 mm radius of transitional curvature were analyzed. Results: Max-S1 was observed at the transitional part and decreased with increasing radius of the transitional curvature, rest width, and thickness. PEEK rests with at least 1.5 mm thicknesses and 3.0 mm widths showed lower Max-S1 than the flexural strength. Max-S1 of all PEEK rests exceeded the PEEK fatigue strength, whereas Max-S1 of the zirconia rests was lower than the zirconia fatigue strength. Conclusion: Zirconia occlusal rests with conventional metal rest designs have sufficient fatigue strength. PEEK occlusal rests have insufficient fatigue strength and may not withstand repeated mastication.
- 1 January 2023
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 67 (2) , 196-205
Open AccessEvaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis
Purpose: We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis. Methods: Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.0 mm width) and minor connector (1.5 mm thickness, 6.0 mm height), and rest seat models with mechanical properties of enamel were constructed. The radius of transitional curvature between the rest and minor connector was 0.1-0.5 mm. The rest and rest seat model interfaces were set as frictional contacts (μ = 0.1), and the base of the rest seat model was restrained in all the directions. A 100 N downward load was applied perpendicular to the bottom surface of the minor connector. The maximum value of the first principal stress (Max-S1) was compared to the flexural and fatigue strengths of each material. Occlusal rests with 1.0-2.0 mm thickness, 2.0-3.5 mm width, and 0.5 mm radius of transitional curvature were analyzed. Results: Max-S1 was observed at the transitional part and decreased with increasing radius of the transitional curvature, rest width, and thickness. PEEK rests with at least 1.5 mm thicknesses and 3.0 mm widths showed lower Max-S1 than the flexural strength. Max-S1 of all PEEK rests exceeded the PEEK fatigue strength, whereas Max-S1 of the zirconia rests was lower than the zirconia fatigue strength. Conclusion: Zirconia occlusal rests with conventional metal rest designs have sufficient fatigue strength. PEEK occlusal rests have insufficient fatigue strength and may not withstand repeated mastication.
- Open Access
- 13 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (24) , 7392
Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D). The evaluated measures were trueness, precision, and linear accuracy. One-way and two-way ANOVA were performed for the comparison of trueness and linear accuracy, while Kruskal–Wallis test was performed for the precision comparison (α = 0.05). 45M and 45D showed significantly superior trueness of #34 to 37M and 34D. 45M also showed significantly superior trueness of #45 to 34. 45D showed significantly inferior linear accuracy of #34 and superior linear accuracy of #45 compared to other strategies. It was concluded that scanning origin location would have an impact on data accuracy of RPD abutment teeth region in digital impressions acquired by intraoral scanner.
- 13 December 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (24) , 7392
Open AccessEffect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D). The evaluated measures were trueness, precision, and linear accuracy. One-way and two-way ANOVA were performed for the comparison of trueness and linear accuracy, while Kruskal–Wallis test was performed for the precision comparison (α = 0.05). 45M and 45D showed significantly superior trueness of #34 to 37M and 34D. 45M also showed significantly superior trueness of #45 to 34. 45D showed significantly inferior linear accuracy of #34 and superior linear accuracy of #45 compared to other strategies. It was concluded that scanning origin location would have an impact on data accuracy of RPD abutment teeth region in digital impressions acquired by intraoral scanner.