Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Natsuko Murakami has a total of 72 co-authors. Here are the top co-authors by number of shared publications:

  • Noriyuki Wakabayashi

    Advanced Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan

    11 shared publications
  • Noriyuki Wakabayashi

    Professor, Department of Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan

    8 shared publications
  • Toshiki Yamazaki

    Advanced Prosthodontics, Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan

    7 shared publications
  • Hidekazu Takahashi

    Course of Oral Health Engineering, School of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University (TMDU)

    4 shared publications
  • Junichiro Wada

    Department of Advanced Prosthodontics, Institute of Science Tokyo, Tokyo, Japan

    4 shared publications
  • Hitomi Matsuno

    Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Institution of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan

    3 shared publications

Latest Publications

  • Finite Element Simulation of Two Vowel Changes in a Male Vocal Tract Model With an Aramany Class I Maxillectomy

    by Ahmed Sameir Mohamed Ali, Mariko Hattori, Yuka I. Sumita, Takayuki Arai, Natsuko Murakami, Noriyuki Wakabayashi

  • Nasal function in patients with maxillectomy using various obturator designs

    by Ahmed Sameir Mohamed Ali, Yuka I. Sumita, Masako Akiyama, Islam E. Ali, Natsuko Murakami, Noriyuki Wakabayashi


  • Effects of tensile and compressive stress on bone resorption and formation parameters surrounding dental implants

    by Bin Li, Natsuko Murakami, Cangyou Xie, Yuki Mouri, Hitomi Matsuno, Hisami Okawara, Kazuhiro Aoki, Noriyuki Wakabayashi


  • Open Access

    Evaluation of Fitting Accuracy of Light- and Auto-Polymerizing Reline Materials Using Three-Dimensional Measurement Techniques

    by Miona Utsumi, Natsuko Murakami, Toshiki Yamazaki, Asuka Hirata, Kohei Komine, Bin Li, Kensuke Takakusaki, Junichiro Wada, Noriyuki Wakabayashi

    Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner®, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III®, Tokuyama, AP) were used. The gaps formed between the relined denture base and the simplified edentulous model were evaluated. The displacement and deviation of the experimentally relined RPDs on the partially edentulous models were analyzed using 3D data superimposition. In the edentulous model, the gaps at all measurement points were significantly smaller for the AP than in the LP. Moreover, the alveolar ridge crest gap was significantly larger than that at other sites. In the partial denture model, the RMS values at the residual ridge crest were significantly lower for the AP. The evaluation method using 3D scanning and comparison was suitable for a detailed fit analysis. Further improvements in the scanning accuracy may enhance future assessments. Therefore, the evaluation method using 3D scanning and comparison was suitable for effectively analyzing the fit of relines, necessitating further accuracy improvements.


  • Open Access

    Thermal stress behavior of monolithic zirconia crowns with different thicknesses

    by Kohei Komine, Natsuko Murakami, Junichiro Wada, Toshiki Yamazaki, Li Bin, Miona Utsumi, Shiqi Zou, Noriyuki Wakabayashi

    Purpose: This study was aimed at investigating the thermal stresses in monolithic zirconia crowns (MZC) of various thicknesses and elucidating their thermal behavior under cooling or heating changes in the oral cavity. Additionally, the clinical availability and potential issues of MZC were examined by comparing them with other crown materials.Methods: Finite element models comprising MZC (0.5-, 1.0-, and 1.5-mm thick), cement layers, and abutment teeth were subjected to thermal changes from 37 to 5 °C or 60 °C. Using a thermal distribution at 5 s, the thermal stress was calculated and compared with those of gold alloy and resin composite crowns. The loads corresponding to the thermal stresses were also estimated by comparing them with the stresses induced by vertical loading on the occlusal surface.Results: Tensile stress occurred primarily in the crowns and cement during cooling, whereas compressive stress was generated during heating. Thermal stresses increased from 16.0 to 27.2 MPa with decreasing crown thickness from 1.5 to 0.5 mm and varied with different materials. Although the MZC exhibited the highest thermal stress, the estimated load (200 N) corresponding to the thermal stress was smaller than that of the resin composite (1280 N).Conclusions: Thinner crowns exhibited higher thermal stress, suggesting an increased risk of failure owing to thermal changes. Despite the higher thermal stress in thinner MZC, the stresses were below the fatigue strength of the material, indicating sufficient resistance to thermal changes in the oral cavity.


  • Open Access

    Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study

    by Yurika Ishioka, Junichiro Wada, Eung-Yeol Kim, Kazuki Sakamoto, Yuki Arai, Natsuko Murakami, Toshiki Yamazaki, Kensuke Takakusaki, Hironari Hayama, Miona Utsumi, et al.

    Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman’s ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression.


  • Open Access

    Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments

    by Abdullah Kamel, Toshiki Yamazaki, Natsuko Murakami, Huaxin Lyu, Kohei Komine, Amr Badr, Gehan Fekry, Hidekazu Takahashi, Noriyuki Wakabayashi

    This study aimed to evaluate the retentive force of polyetheretherketone (PEEK) and zirconia secondary crowns on ready-made titanium implant abutments (with height, diameter, and taper as 5.5 mm, 4.5 mm, and 6°, respectively) as the primary crown. PEEK, zirconia, and titanium secondary crowns were fabricated using a CAD/CAM system. Insertion and removal tests of secondary crowns on the primary crown were conducted for 2,000 cycles. The initial retentive forces recorded at the 100th cycle for PEEK, zirconia, and titanium were 13.0±7.9, 2.9±2.6, and 27.6±1.7 N, respectively. The retentive forces of PEEK and zirconia showed no significant difference among all cycles. However, the retentive force of the titanium used as a control decreased (20.3±2.8 N) significantly at the 2,000th cycle. Although the retentive force of PEEK was lower than that of titanium, it was within the range that can provide a suitable retentive force of 5 N for removable dental prostheses.


  • Effect of tension and compression on dynamic alveolar histomorphometry

    by Hitomi Matsuno, Bin Li, Hisami Okawara, Yusuke Toyoshima, Cangyou Xie, Masud Khan, Natsuko Murakami, Kazuhiro Aoki, Noriyuki Wakabayashi


  • Open Access

    Evaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis

    by Huaxin Lyu, Natsuko Murakami, Toshiki Yamazaki, Junichiro Wada, Miona Utsumi, Noriyuki Wakabayashi

    Purpose: We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis. Methods: Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.0 mm width) and minor connector (1.5 mm thickness, 6.0 mm height), and rest seat models with mechanical properties of enamel were constructed. The radius of transitional curvature between the rest and minor connector was 0.1-0.5 mm. The rest and rest seat model interfaces were set as frictional contacts (μ = 0.1), and the base of the rest seat model was restrained in all the directions. A 100 N downward load was applied perpendicular to the bottom surface of the minor connector. The maximum value of the first principal stress (Max-S1) was compared to the flexural and fatigue strengths of each material. Occlusal rests with 1.0-2.0 mm thickness, 2.0-3.5 mm width, and 0.5 mm radius of transitional curvature were analyzed. Results: Max-S1 was observed at the transitional part and decreased with increasing radius of the transitional curvature, rest width, and thickness. PEEK rests with at least 1.5 mm thicknesses and 3.0 mm widths showed lower Max-S1 than the flexural strength. Max-S1 of all PEEK rests exceeded the PEEK fatigue strength, whereas Max-S1 of the zirconia rests was lower than the zirconia fatigue strength. Conclusion: Zirconia occlusal rests with conventional metal rest designs have sufficient fatigue strength. PEEK occlusal rests have insufficient fatigue strength and may not withstand repeated mastication.


  • Open Access

    Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study

    by Eung-Yeol Kim, Junichiro Wada, Kazuki Sakamoto, Yurika Ishioka, Yuki Arai, Natsuko Murakami, Toshiki Yamazaki, Hironari Hayama, Miona Utsumi, Shusuke Inukai, et al.

    The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D). The evaluated measures were trueness, precision, and linear accuracy. One-way and two-way ANOVA were performed for the comparison of trueness and linear accuracy, while Kruskal–Wallis test was performed for the precision comparison (α = 0.05). 45M and 45D showed significantly superior trueness of #34 to 37M and 34D. 45M also showed significantly superior trueness of #45 to 34. 45D showed significantly inferior linear accuracy of #34 and superior linear accuracy of #45 compared to other strategies. It was concluded that scanning origin location would have an impact on data accuracy of RPD abutment teeth region in digital impressions acquired by intraoral scanner.