Exploration of the pulse pileup effects in a clinical CdTe‐based photon‐counting computed tomography
Authors:
- 21 August 2023
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 50 (11) , 6693-6703
Abstract
Background: High tube current generates a high flux of x‐rays to photon counting detectors (PCDs) that can potentially result in the piling up of pulses formed by concurrent photons, which can cause count loss and energy resolution degradation.Purpose: To evaluate the performance of clinical photon‐counting CT (PCCT) systems in high flux, potentially influenced by pulse pileup effects, in terms of task‐generic image quality metrics.Methods: A clinical phantom was scanned on a commercial PCCT scanner (NAEOTOM Alpha, Siemens) at 120 kV under fourteen different tube current levels (40–1000 mA) with a rotation time of 0.25 s and a pitch of 1. The dose levels corresponded to CTDIvol(32 cm phantom) of 0.79–19.8 mGy. CT sinograms were reconstructed using QIR‐off mode (noniterative reconstruction algorithm), Br44 kernel, and a voxel size of . imQuest, an open‐source MATLAB‐based software package was used to calculate noise power spectrum (NPS), task transfer function (TTF), contrast‐to‐noise ratio (CNR), and CT number according to AAPM Task Group 233 metrology.Results: The 50% cut‐off frequency of TTF (f50) remained mostly constant across all higher tube currents for all inserts, namely polyethylene, bone, air, and acrylic. Using the lowest two data points (40 and 80 mA), the expected relationship between noise magnitude and tube current was determined to be noise mA−0.47. The measured noise magnitude were up to 11.1% higher than the expected value at the highest tube current. The average frequency of NPS (fav) decreased from 0.32 to 0.29 mm−1as tube current increased from 40 to 1000 mA. No considerable effects were observed in CT number measurement of any insert; however, CT numbers for air and bone changed almost monotonically as tube current increased. Absolute CNR increased monotonically for all inserts; however, the difference between measured and expected CNRs were approximately −6% to 12% across all tube currents.Conclusions: Increasing tube currents did not affect the spatial resolution, but slightly affected the CT number and noise measurements of the clinical PCCT system. However, the effects were only considerable at clinically irrelevant tube currents used on a small 20‐cm phantom. In general clinical practices, automatic exposure control techniques are used to decrease the variation of flux on the detector, which alleviates the chances of detector saturation due to high count rates. The observed effects could be due to pulse pileup, signal‐dependent filtration of the system, or nonlinearities in the reconstruction algorithm. In conclusion, either the deadtime of the detector used in the photon‐counting CT system is shorter such that count losses due to pulse pileup are negligible, or pulse pileup has inconsiderable effects on the image quality of clinical photon‐counting CT systems in routine clinical practice due to possible corrections applied on the system.Keywords
Funding Information
- National Institutes of Health (R01EB001838, R01HL155293, P41EB028744)
This publication has 22 references indexed in Scilit:
- A Fourier approach to pulse pile‐up in photon‐counting x‐ray detectorsMedical Physics, 2016
- Characteristic image quality of a third generation dual‐source MDCT scanner: Noise, resolution, and detectabilityMedical Physics, 2015
- Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methodsMedical Physics, 2014
- A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon‐counting x‐ray detector for CTMedical Physics, 2014
- Quantitative comparison of noise texture across CT scanners from different manufacturersMedical Physics, 2012
- Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithmsMedical Physics, 2012
- Pulse pileup statistics for energy discriminating photon counting x‐ray detectorsMedical Physics, 2011
- Modeling the performance of a photon counting x‐ray detector for CT: Energy response and pulse pileup effectsMedical Physics, 2011
- An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x‐ray detectorsMedical Physics, 2010
- The phantom portion of the American College of Radiology (ACR) Computed Tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoidMedical Physics, 2004