Abstract
The uranium neutron coincidence collar uses thermal neutron interrogation to verify the 235U mass in low-enriched uranium (LEU) fuel assemblies in fuel fabrication facilities. Burnable poisons are commonly added to nuclear fuel to increase the lifetime of the fuel. The high thermal neutron absorption by these poisons reduces the active neutron signal produced by the fuel. Burnable poison correction factors or fast-mode runs with Cd liners can help compensate for this effect, but the correction factors rely on operator declarations of burnable poison content, and fast-mode runs are time-consuming. This paper describes a new analysis method to measure the 235U mass and burnable poison content in LEU nuclear fuel simultaneously in a timely manner, without requiring additional hardware.Keywords
Funding Information
- Los Alamos National Laboratory (LA-UR-17-31390)
This publication has 6 references indexed in Scilit:
- Technical Basis for the Use of a Correlated Neutron Source in the Uranium Neutron Coincidence CollarNuclear Technology, 2017
- Monte carlo feasibility study of an active neutron assay technique for full-volume UF6 cylinder assay using a correlated interrogation sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- The development of a new, neutron, time correlated, interrogation method for measurement of 235U content in LWR fuel assembliesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Comparison of fresh fuel experimental measurements to MCNPX calculations using self-interrogation neutron resonance densitometryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Neutron collar calibration and evaluation for assay of LWR fuel assemblies containing burnable neutron absorbers1990
- Neutron collar calibration for assay of LWR (light-water reactor) fuel assemblies1987