Carlos D. Rael
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Carlos D. Rael has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
H. O. Menlove
Los Alamos National Laboratory, P.O. Box 1663, Mail Stop E-540, Los Alamos, New Mexico 87545
2 shared publicationsH.O. Menlove
2 shared publicationsHoward O. Menlove
Los Alamos National Laboratory, Los Alamos, NM 87544, USA
2 shared publications- Margaret A. Root
Los Alamos National Laboratory
2 shared publications Se-Hwan Park
Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea
2 shared publications- Taylor Joseph Harvey
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
2 shared publications
Latest Publications
- Open Access
- 4 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
SFRC Measurement Control Summary - FY23 Q3/Q4
The U.S. Department of Energy's Office of Scientific and Technical Information
- 4 October 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessSFRC Measurement Control Summary - FY23 Q3/Q4
The U.S. Department of Energy's Office of Scientific and Technical Information
- 3 August 2023
- Published by Office of Scientific and Technical Information (OSTI)
Plutonium Basket Counter Measurement Control Q3-Q4 2023
The U.S. Department of Energy's Office of Scientific and Technical Information
- 3 August 2023
- Published by Office of Scientific and Technical Information (OSTI)
Plutonium Basket Counter Measurement Control Q3-Q4 2023
The U.S. Department of Energy's Office of Scientific and Technical Information
- 18 January 2022
- Published by Office of Scientific and Technical Information (OSTI)
He-3 Based Neutron Detector, Basic Troubleshooting [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 18 January 2022
- Published by Office of Scientific and Technical Information (OSTI)
He-3 Based Neutron Detector, Basic Troubleshooting [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 18 January 2022
- Published by Office of Scientific and Technical Information (OSTI)
Traditional Method for Amplifier Matching for NDA Detector Systems [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 18 January 2022
- Published by Office of Scientific and Technical Information (OSTI)
Traditional Method for Amplifier Matching for NDA Detector Systems [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 19 October 2020
- Published by Office of Scientific and Technical Information (OSTI)
UFCC Calibration Measurements for Bulk U3O8 Powder Samples
The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF 6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. The sample enrichments varied from 0.72% to 91% to establish the shape of the calibration curve and the measurement uncertainties. The measurements included the singles, doubles, and triples rates. The time correlations between the 252Cf source and the induced fission reactions reduced the statistical error in the doubles and triples rates to be small enough for useful measurements in 5-10 minutes.
- 19 October 2020
- Published by Office of Scientific and Technical Information (OSTI)
UFCC Calibration Measurements for Bulk U3O8 Powder Samples
The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF 6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. The sample enrichments varied from 0.72% to 91% to establish the shape of the calibration curve and the measurement uncertainties. The measurements included the singles, doubles, and triples rates. The time correlations between the 252Cf source and the induced fission reactions reduced the statistical error in the doubles and triples rates to be small enough for useful measurements in 5-10 minutes.
- Open Access
- 21 March 2018
- Published by Taylor & Francis in Nuclear Technology
- Vol. 203 (1) , 34-47
Using the Time-Correlated Induced Fission Method to Simultaneously Measure the235U Content and the Burnable Poison Content in LWR Fuel Assemblies
The uranium neutron coincidence collar uses thermal neutron interrogation to verify the 235U mass in low-enriched uranium (LEU) fuel assemblies in fuel fabrication facilities. Burnable poisons are commonly added to nuclear fuel to increase the lifetime of the fuel. The high thermal neutron absorption by these poisons reduces the active neutron signal produced by the fuel. Burnable poison correction factors or fast-mode runs with Cd liners can help compensate for this effect, but the correction factors rely on operator declarations of burnable poison content, and fast-mode runs are time-consuming. This paper describes a new analysis method to measure the 235U mass and burnable poison content in LEU nuclear fuel simultaneously in a timely manner, without requiring additional hardware.
- 21 March 2018
- Published by Taylor & Francis in Nuclear Technology
- Vol. 203 (1) , 34-47
Open AccessUsing the Time-Correlated Induced Fission Method to Simultaneously Measure the235U Content and the Burnable Poison Content in LWR Fuel Assemblies
The uranium neutron coincidence collar uses thermal neutron interrogation to verify the 235U mass in low-enriched uranium (LEU) fuel assemblies in fuel fabrication facilities. Burnable poisons are commonly added to nuclear fuel to increase the lifetime of the fuel. The high thermal neutron absorption by these poisons reduces the active neutron signal produced by the fuel. Burnable poison correction factors or fast-mode runs with Cd liners can help compensate for this effect, but the correction factors rely on operator declarations of burnable poison content, and fast-mode runs are time-consuming. This paper describes a new analysis method to measure the 235U mass and burnable poison content in LEU nuclear fuel simultaneously in a timely manner, without requiring additional hardware.
- 26 February 2017
- Published by Taylor & Francis in Nuclear Technology
- Vol. 197 (2) , 180-190
Technical Basis for the Use of a Correlated Neutron Source in the Uranium Neutron Coincidence Collar
(2017). Technical Basis for the Use of a Correlated Neutron Source in the Uranium Neutron Coincidence Collar. Nuclear Technology: Vol. 197, No. 2, pp. 180-190. doi: 10.13182/NT16-50
- 26 February 2017
- Published by Taylor & Francis in Nuclear Technology
- Vol. 197 (2) , 180-190
Technical Basis for the Use of a Correlated Neutron Source in the Uranium Neutron Coincidence Collar
(2017). Technical Basis for the Use of a Correlated Neutron Source in the Uranium Neutron Coincidence Collar. Nuclear Technology: Vol. 197, No. 2, pp. 180-190. doi: 10.13182/NT16-50
- 1 September 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 115, 67-73
Development of prototype induced-fission-based Pu accountancy instrument for safeguards applications
- 1 September 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 115, 67-73
Development of prototype induced-fission-based Pu accountancy instrument for safeguards applications
- 1 January 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 806, 43-54
Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration
- 1 January 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 806, 43-54
Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration