Pressure overloaded right ventricles: a multicenter study on the importance of trabeculae in RV function measured by CMR
Authors:
- Mieke M. P. DriessenMieke M. P. Driessen
- Vivan J. M. BaggenVivan J. M. Baggen
- Hendrik G. FrelingHendrik G. Freling
- Petronella G. PieperPetronella G. Pieper
- Arie P. van DijkArie P. van Dijk
- Pieter A. DoevendansPieter A. Doevendans
- Repke J. SnijderRepke J. Snijder
- Marco C. PostMarco C. Post
- Folkert J. MeijboomFolkert J. Meijboom
- Gertjan Tj. SieswerdaGertjan Tj. Sieswerda
- Tim LeinerTim Leiner
- Tineke P. WillemsTineke P. Willems
- 20 January 2014
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 30 (3) , 599-608
Abstract
Cardiac magnetic resonance (CMR) imaging is the preferred method to measure right ventricular (RV) volumes and ejection fraction (RVEF). This study aimed to determine the impact of excluding trabeculae and papillary muscles on RV volumes and function in patients with RV pressure and/or volume overload and healthy controls and its reproducibility using semi-automatic software. Eighty patients (pulmonary hypertension, transposition of the great arteries after arterial switch operation and after atrial switch procedure and repaired Tetralogy of Fallot) and 20 controls underwent short-axis multislice cine CMR. End diastolic volume (EDV), end systolic volume (ESV), RV mass and RVEF were measured using 2 methods. First, manual contour tracing of RV endo- and epi-cardial borders was performed. Thereafter, trabeculae were excluded from the RV blood volume using semi-automatic pixel-intensity based software. Both methods were compared using a Student T test and 25 datasets were re-analyzed for reproducibility. Exclusion of trabeculae resulted in significantly decreased EDV; ranging from −5.7 ± 1.7 ml/m2 in controls to −29.2 ± 6.6 ml/m2 in patients after atrial switch procedure. RVEF significantly increased in all groups, ranging from an absolute increase of 3.4 ± 0.8 % in healthy controls to 10.1 ± 2.3 % in patients after atrial switch procedure. Interobserver agreement of method 2 was equal to method 1 for RVEDV, RVESV and RVEF and superior for RV mass. In patients with overloaded RVs exclusion of trabeculae from the blood volume results in a significant change in RV volumes, RVEF and RV mass. Exclusion of trabeculae is highly reproducible when semi-automatic pixel-intensity based software is used.Keywords
This publication has 27 references indexed in Scilit:
- Improved Cardiac MRI Volume Measurements in Patients with Tetralogy of Fallot by Independent End-Systolic and End-Diastolic Phase SelectionPLOS ONE, 2013
- Impact of right ventricular endocardial trabeculae on volumes and function assessed by CMR in patients with tetralogy of FallotThe International Journal of Cardiovascular Imaging, 2012
- Outcomes of Pulmonary Valve Replacement in 170 Patients With Chronic Pulmonary Regurgitation After Relief of Right Ventricular Outflow Tract ObstructionJACC, 2012
- ESC Guidelines for the management of grown-up congenital heart disease (new version 2010): The Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of Cardiology (ESC)European Heart Journal, 2010
- Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of CardiologyEuropean Heart Journal, 2010
- Comparison of Accuracy of Axial Slices Versus Short-Axis Slices for Measuring Ventricular Volumes by Cardiac Magnetic Resonance in Patients With Corrected Tetralogy of FallotThe American Journal of Cardiology, 2009
- Evaluating the systemic right ventricle by CMR: the importance of consistent and reproducible delineation of the cavityJournal of Cardiovascular Magnetic Resonance, 2008
- Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repairThe American Journal of Cardiology, 2005
- Magnetic Resonance Imaging and Echocardiography in Assessment of Ventricular Function in Atrially Corrected Transposition of the Great ArteriesScandinavian Cardiovascular Journal, 2000
- Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart diseaseAmerican Heart Journal, 1995