Optimization analyses on the performance of an auto-cascade absorption refrigeration system operating with mixed refrigerants
Authors:
Open Access
- 30 April 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 13 (3) , 212-217
Abstract
Waste heat can be well utilized in absorption refrigeration systems. The auto-cascade absorption refrigeration system could obtain a lower temperature than that of the traditional absorption refrigeration system since the non-azeotropic mixed refrigerants with large temperature glides were used. In this article, the performance of an auto-cascade absorption refrigeration system using R23/R134a/DMF (dimethylformamide) solutions as the working substance was analyzed. Optimization analysis results showed that, to some extent, the coefficient of performance (COP) could be increased when the low pressure of the system decreased or the high pressure increased. The reasonable upper limit of the high pressure was the high pressure at the turning point of COP, and the reasonable lower limit of the low pressure was the low pressure at the turning point of COP. The COP of the system monotonously increased with the increase of the mole fraction of R23 in solutions. The low R23 mole fraction solutions were more appropriate.Keywords
Funding Information
- Zhejiang Province (2016C31125)
- Industrial project of public welfare technology research in Zhejiang Province (2016C31125)
This publication has 10 references indexed in Scilit:
- Comparative study on two low-grade heat driven absorption-compression refrigeration cycles based on energy, exergy, economic and environmental (4E) analysesEnergy Conversion and Management, 2017
- Comparative study on the energy performance of two different absorption-compression refrigeration cycles driven by low-grade heatApplied Thermal Engineering, 2016
- A novel low-temperature absorption–compression cascade refrigeration systemApplied Thermal Engineering, 2015
- Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor–liquid separators and environmentally benign binary refrigerantsApplied Energy, 2013
- An investigation of the mixing position in the recuperators on the performance of an auto-cascade refrigerator operating with a rectifying columnCryogenics, 2012
- Solubility of refrigerant trifluoromethane in N,N-dimethyl formamide in the temperature range from 283.15 K to 363.15 KInternational Journal of Refrigeration, 2012
- Solubility of Refrigerant 1,1,1,2-Tetrafluoroethane in theN,N-Dimethyl Formamide in the Temperature Range from (263.15 to 363.15) KJournal of Chemical & Engineering Data, 2011
- Performance of a single-stage auto-cascade refrigerator operating with a rectifying column at the temperature level of −60 °CJournal of Zhejiang University-SCIENCE A, 2011
- Experimental study on an absorption refrigeration system at low temperaturesInternational Journal of Thermal Sciences, 2007
- Heat driven refrigeration cycle at low temperaturesChinese Science Bulletin, 2005