Qin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qin Wang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Guangming Chen
Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
4 shared publications Guang-Ming Chen
Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou, 310027, China
3 shared publicationsJielin Luo
Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
3 shared publicationsZhen Zhao
Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
3 shared publicationsJie-Lin Luo
Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou, 310027, China
2 shared publicationsJing-Peng Zhang
Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou, 310027, China
2 shared publications
Latest Publications
- 7 April 2022
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 14 (9) , 1-27
Investigations on the Cycle Performance of a Diffusion Absorption Heat Transformer Using HCOOK as an Alternative to LiBr
A diffusion absorption heat transformer is very potential to improve energy utilization efficiency and reduce carbon emission, because it can be totally driven by waste heat without electricity consumption. On the base of a simulation model, the cycle performance of a diffusion absorption heat transformer using HCOOK-H2O-R134a-TEGDME and LiBr-H2O-R134a-TEGDME is compared under specified temperatures of Generator A, Generator B, Evaporator, Condenser, Low Temperature Absorber and High Temperature Absorber. The influences of six temperatures on cycle performance are assessed and COP is found more sensitive to the temperatures of Generator B and High Temperature Absorber. High COP corresponds with small diffusion gas supply ratio and small proportion of the heat input to Generator A in the total thermal power input. The employment of HCOOK instead of LiBr is beneficial to increasing COP in optimized conditions. In the design temperature conditions, COP can be increased from 0.170 to 0.178 in the system using HCOOK instead of LiBr. Meanwhile, diffusion gas supply ratio, proportion of the heat input to Generator A, and pumping ratio of Lifting Tube B can be decreased 0.368, 0.022, and 0.098 respectively. The diffusion absorption heat transformer will provide a new way to lift temperature of low grade heat for more availability without electricity input and improve the energy utilization efficiency.
- 7 April 2022
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 14 (9) , 1-27
Investigations on the Cycle Performance of a Diffusion Absorption Heat Transformer Using HCOOK as an Alternative to LiBr
A diffusion absorption heat transformer is very potential to improve energy utilization efficiency and reduce carbon emission, because it can be totally driven by waste heat without electricity consumption. On the base of a simulation model, the cycle performance of a diffusion absorption heat transformer using HCOOK-H2O-R134a-TEGDME and LiBr-H2O-R134a-TEGDME is compared under specified temperatures of Generator A, Generator B, Evaporator, Condenser, Low Temperature Absorber and High Temperature Absorber. The influences of six temperatures on cycle performance are assessed and COP is found more sensitive to the temperatures of Generator B and High Temperature Absorber. High COP corresponds with small diffusion gas supply ratio and small proportion of the heat input to Generator A in the total thermal power input. The employment of HCOOK instead of LiBr is beneficial to increasing COP in optimized conditions. In the design temperature conditions, COP can be increased from 0.170 to 0.178 in the system using HCOOK instead of LiBr. Meanwhile, diffusion gas supply ratio, proportion of the heat input to Generator A, and pumping ratio of Lifting Tube B can be decreased 0.368, 0.022, and 0.098 respectively. The diffusion absorption heat transformer will provide a new way to lift temperature of low grade heat for more availability without electricity input and improve the energy utilization efficiency.
- 17 November 2021
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 14 (3)
Theoretical Investigation on the Heating Performance of a Recuperative Heat Pump Water Heater Using CO2/HCs With Large Temperature Glides in Cold Regions
Considering the issues of environmental pollution and energy efficiency, heat pumps are gradually replacing traditional coal combustion for heating at low ambient temperatures. In this paper, eco-friendly CO2/HCs with large temperature glides are applied in a single-stage recuperative heat pump water heater. Its heating performance is theoretically investigated under the working condition of producing circulating hot water in typical winter of northern China, with medium temperature difference between supply/return water and large temperature difference between air inlet and water inlet. Due to its simple structure, low initial investment and high efficiency, its potential for producing circulating hot water is demonstrated. Exergy analyses are conducted to reveal the significant influence of the exergy losses of heat exchanger on system performance. For specified CO2/HC, optimal COP is obtained through global optimization of cycle pressures and mixture concentration. The heating performances of different CO2/HCs are compared, among which CO2/R600 and CO2/R600a behave better. Meanwhile, a typical vapor-injection cycle is used to demonstrate priorities on the heating performance of this recuperative cycle, in which the COP of recuperative cycle using CO2/R600 is more than 3.4% higher than that of the vapor-injection cycle. The results obtained in this paper provide a simple and efficient solution for producing circulating hot water at low ambient temperatures.
- 17 November 2021
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 14 (3)
Theoretical Investigation on the Heating Performance of a Recuperative Heat Pump Water Heater Using CO2/HCs With Large Temperature Glides in Cold Regions
Considering the issues of environmental pollution and energy efficiency, heat pumps are gradually replacing traditional coal combustion for heating at low ambient temperatures. In this paper, eco-friendly CO2/HCs with large temperature glides are applied in a single-stage recuperative heat pump water heater. Its heating performance is theoretically investigated under the working condition of producing circulating hot water in typical winter of northern China, with medium temperature difference between supply/return water and large temperature difference between air inlet and water inlet. Due to its simple structure, low initial investment and high efficiency, its potential for producing circulating hot water is demonstrated. Exergy analyses are conducted to reveal the significant influence of the exergy losses of heat exchanger on system performance. For specified CO2/HC, optimal COP is obtained through global optimization of cycle pressures and mixture concentration. The heating performances of different CO2/HCs are compared, among which CO2/R600 and CO2/R600a behave better. Meanwhile, a typical vapor-injection cycle is used to demonstrate priorities on the heating performance of this recuperative cycle, in which the COP of recuperative cycle using CO2/R600 is more than 3.4% higher than that of the vapor-injection cycle. The results obtained in this paper provide a simple and efficient solution for producing circulating hot water at low ambient temperatures.
- 4 November 2021
- Published by American Chemical Society (ACS) in Journal of Chemical & Engineering Data
- Vol. 66 (12) , 4293-4299
Experimental Research on the Vapor Pressures of CaCl2–H2O and MgCl2–H2O as Working Fluids of Absorption Heat Transformers at High Temperature
- 4 November 2021
- Published by American Chemical Society (ACS) in Journal of Chemical & Engineering Data
- Vol. 66 (12) , 4293-4299
Experimental Research on the Vapor Pressures of CaCl2–H2O and MgCl2–H2O as Working Fluids of Absorption Heat Transformers at High Temperature
- Open Access
- 19 May 2020
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 21 (5) , 406
Erratum to: Development of natural gas liquefaction processes using mixed refrigerants: a review of featured process configurations and performance
The original version of this article unfortunately contained a mistake. In p.750, the sentence “Therefore, it is hard to recommend operation stated,
- 19 May 2020
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 21 (5) , 406
Open AccessErratum to: Development of natural gas liquefaction processes using mixed refrigerants: a review of featured process configurations and performance
The original version of this article unfortunately contained a mistake. In p.750, the sentence “Therefore, it is hard to recommend operation stated,
- 3 February 2020
- Published by American Chemical Society (ACS) in Journal of Chemical & Engineering Data
- Vol. 65 (2) , 561-566
Vapor Pressure of Aqueous HCOOK Solution as Working Fluids of an Absorption Heat Transformer at High Temperature
- 3 February 2020
- Published by American Chemical Society (ACS) in Journal of Chemical & Engineering Data
- Vol. 65 (2) , 561-566
Vapor Pressure of Aqueous HCOOK Solution as Working Fluids of an Absorption Heat Transformer at High Temperature
- 11 October 2019
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 20 (10) , 727-780
Development of natural gas liquefaction processes using mixed refrigerants: a review of featured process configurations and performance
It is preferable to transport or store natural gas (NG) in a liquid state, as liquefied natural gas (LNG). In recent decades, a variety of natural gas liquefaction processes (NGLPs) using mixed...
- 11 October 2019
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 20 (10) , 727-780
Development of natural gas liquefaction processes using mixed refrigerants: a review of featured process configurations and performance
It is preferable to transport or store natural gas (NG) in a liquid state, as liquefied natural gas (LNG). In recent decades, a variety of natural gas liquefaction processes (NGLPs) using mixed...
- 29 January 2019
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 11 (3)
Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa
HFO-1336mzz-Z with low global warming potential (GWP) was considered as a promising alternative of HCFC-123, HFC-245fa in air conditioning (AC) and heat pump (HP), respectively. In order to understand the operation performances of HFO-1336mzz-Z and HCFC-123, HFC-245fa in different working conditions, an experimental setup for testing the refrigeration cycle performance was built. The cycle performances of HFO-1336mzz-Z and HCFC-123 in AC conditions, HFO-1336mzz-Z and HFC-245fa in HP conditions were investigated by experiment. It was found in AC conditions, the discharge temperatures for the systems with HFO-1336mzz-Z and HCFC-123 were lower than 115 °C, the cooling capacity of the system with HFO-1336mzz-Z was 27% less than that with HCFC-123 at least, and the coefficient of performance (COP) of the system with HFO-1336mzz-Z was 0.1 lower than that with HCFC-123; in HP conditions, the discharge temperature with HFO-1336mzz-Z was lower than that with HFC-245fa, the former was never over 115 °C while the latter was up to 126 °C, the power input to the compressor with HFO-1336mzz-Z was 20% less than that with HFC-245fa in the same HP conditions, the heating capacity of the system with HFO-1336mzz-Z was 30–40% less than that with HFC-245fa.
- 29 January 2019
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 11 (3)
Experimental Evaluation on Low Global Warming Potential HFO-1336mzz-Z as an Alternative to HCFC-123 and HFC-245fa
HFO-1336mzz-Z with low global warming potential (GWP) was considered as a promising alternative of HCFC-123, HFC-245fa in air conditioning (AC) and heat pump (HP), respectively. In order to understand the operation performances of HFO-1336mzz-Z and HCFC-123, HFC-245fa in different working conditions, an experimental setup for testing the refrigeration cycle performance was built. The cycle performances of HFO-1336mzz-Z and HCFC-123 in AC conditions, HFO-1336mzz-Z and HFC-245fa in HP conditions were investigated by experiment. It was found in AC conditions, the discharge temperatures for the systems with HFO-1336mzz-Z and HCFC-123 were lower than 115 °C, the cooling capacity of the system with HFO-1336mzz-Z was 27% less than that with HCFC-123 at least, and the coefficient of performance (COP) of the system with HFO-1336mzz-Z was 0.1 lower than that with HCFC-123; in HP conditions, the discharge temperature with HFO-1336mzz-Z was lower than that with HFC-245fa, the former was never over 115 °C while the latter was up to 126 °C, the power input to the compressor with HFO-1336mzz-Z was 20% less than that with HFC-245fa in the same HP conditions, the heating capacity of the system with HFO-1336mzz-Z was 30–40% less than that with HFC-245fa.
- Open Access
- 30 April 2018
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 13 (3) , 212-217
Optimization analyses on the performance of an auto-cascade absorption refrigeration system operating with mixed refrigerants
Waste heat can be well utilized in absorption refrigeration systems. The auto-cascade absorption refrigeration system could obtain a lower temperature than that of the traditional absorption refrigeration system since the non-azeotropic mixed refrigerants with large temperature glides were used. In this article, the performance of an auto-cascade absorption refrigeration system using R23/R134a/DMF (dimethylformamide) solutions as the working substance was analyzed. Optimization analysis results showed that, to some extent, the coefficient of performance (COP) could be increased when the low pressure of the system decreased or the high pressure increased. The reasonable upper limit of the high pressure was the high pressure at the turning point of COP, and the reasonable lower limit of the low pressure was the low pressure at the turning point of COP. The COP of the system monotonously increased with the increase of the mole fraction of R23 in solutions. The low R23 mole fraction solutions were more appropriate.
- 30 April 2018
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 13 (3) , 212-217
Open AccessOptimization analyses on the performance of an auto-cascade absorption refrigeration system operating with mixed refrigerants
Waste heat can be well utilized in absorption refrigeration systems. The auto-cascade absorption refrigeration system could obtain a lower temperature than that of the traditional absorption refrigeration system since the non-azeotropic mixed refrigerants with large temperature glides were used. In this article, the performance of an auto-cascade absorption refrigeration system using R23/R134a/DMF (dimethylformamide) solutions as the working substance was analyzed. Optimization analysis results showed that, to some extent, the coefficient of performance (COP) could be increased when the low pressure of the system decreased or the high pressure increased. The reasonable upper limit of the high pressure was the high pressure at the turning point of COP, and the reasonable lower limit of the low pressure was the low pressure at the turning point of COP. The COP of the system monotonously increased with the increase of the mole fraction of R23 in solutions. The low R23 mole fraction solutions were more appropriate.
- 4 August 2017
- Published by Taylor & Francis in Drying Technology
- Vol. 36 (6) , 697-708
Thermodynamic analysis of a freeze-dryer utilizing hygroscopic solution
- 4 August 2017
- Published by Taylor & Francis in Drying Technology
- Vol. 36 (6) , 697-708
Thermodynamic analysis of a freeze-dryer utilizing hygroscopic solution