A Study on Analysis of Labeling Efficiency Depending on Mixing Time in Asan Medical Center Red Blood Cell Labeling Method
- 25 April 2014
- journal article
- research article
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 47 (9) , 710-715
Abstract
The aim of this study was to overcome the shortcomings of technetium-99m red blood cell labeling, such as the requirement of additional time, and to maintain a stable labeling efficiency by reducing the mixing time for technetium-99m red blood cell labeling in the Asan Medical Center red blood cell labeling method developed by this hospital. Thirty patients, who underwent an examination using technetium-99m red blood cell labeling in the nuclear medicine department from April to September 2012, were selected randomly. Blood samples (5 mL per patient) were mixed with acid citrate dextrose, and 1-mL aliquots were taken to make four blood samples. The Asan Medical Center red blood cell labeling method was used for labeling. In this case, the mixing time was set to 5, 10, 15, and 20 min before calculating the efficiency of each labeling. The difference depending on the mixing time was compared. According to the technetium-99m red blood cell labeling efficiency depending on the mixing time in the Asan Medical Center red blood cell labeling method, the efficiency of each labeling was 92 ± 5%, 96 ± 5%, 97 ± 5%, and 98 ± 5% for 5, 10, 15, and 20 min, respectively. Overall, the labeling efficiency was relatively low when the mixing time was 5 min, whereas there was no significant difference in labeling efficiency when the mixing time was longer than 5 min. In conclusion, the Asan Medical Center red blood cell labeling method can provide an environment that is more conducive to the combination of red blood cell with technetium-99m pertechnetate than the previous modified labeling method because the Asan Medical Center red blood cell labeling method removes blood plasma in an additional centrifugation process.Keywords
This publication has 7 references indexed in Scilit:
- Analysis of 99mTc-RBC labeling efficiency between modified in-vitro method and AMC methodAnnals of Nuclear Energy, 2010
- Chocolate Intake Associated with Failed Labeling of 99mTc Red Blood CellsJournal of Nuclear Medicine Technology, 2009
- Evaluation of platelet parameters on the ADVIA 120 as the quality indicator for stored plateletsClinical and Laboratory Haematology, 2002
- Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology systemCytometry, 1999
- Elution characteristics of 99 Tcm-labelled erythrocytes in relation to scintigraphic detection of gastrointestinal bleedingNuclear Medicine Communications, 1991
- Technetium-99m RBC Bleeding Images in Normal Subjects: Confusion with Gastrointestinal Bleeding SitesClinical Nuclear Medicine, 1989
- Radionuclide-labeled red blood cells: Current status and future prospectsSeminars in Nuclear Medicine, 1984