Kyung-Rae Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kyung-Rae Dong has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Woon-Kwan Chung
Department of Nuclear Engineering, Chosun University, Gwangju, Republic of Korea
22 shared publications - Jae-Hwan Cho
Ansan University
11 shared publications - Jae-Seung Lee
Dong Eui University
7 shared publications - Dae Cheol Kweon
Department of Radiological Science, Shinhan University, Uijeongbu, Republic of Korea
6 shared publications - Eun-Hoe Goo
Seoul National University Hospital
6 shared publications - Jong-Woong Lee
Kyung Hee University Hospital at Gang-dong
5 shared publications
Latest Publications
- Open Access
- 1 December 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (4) , 305-307
A Comparative Study on Coronary Angiography and Intervention through Femoral Artery or Radial Artery
- 1 December 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (4) , 305-307
Open AccessA Comparative Study on Coronary Angiography and Intervention through Femoral Artery or Radial Artery
- Open Access
- 1 September 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (3) , 211-217
Survey of Awareness on the Exposure Dose of Extremity and Eye Lens by Radiation Worker in Nuclear Medicine Department
- 1 September 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (3) , 211-217
Open AccessSurvey of Awareness on the Exposure Dose of Extremity and Eye Lens by Radiation Worker in Nuclear Medicine Department
- Open Access
- 1 September 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (3) , 241-244
Measurement of Radiation Exposure in the Front and in the Back for Radiation Worker in Nuclear Medicine Department
- 1 September 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (3) , 241-244
Open AccessMeasurement of Radiation Exposure in the Front and in the Back for Radiation Worker in Nuclear Medicine Department
- Open Access
- 1 June 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (2) , 141-148
A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method
- 1 June 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (2) , 141-148
Open AccessA Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method
- Open Access
- 1 March 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (1) , 79-85
Compare Shielding Performance Evaluation of Lead Alternatives
- 1 March 2015
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 8 (1) , 79-85
Open AccessCompare Shielding Performance Evaluation of Lead Alternatives
- 15 September 2014
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 48 (2) , 84-89
Tooth Distortion as a Function of Arch Form in Cone Beam Computed Tomography
The cone beam computed tomography enables conducting measurement of length and area in the space where it is impossible to conduct such measurement compared to panorama. The cone beam computed tomography also enables making three-dimensional diagnosis and establishing treatment plan. In this experiment, the cone beam computed tomography was used to analyze image distortion of anatomical structure whose location was different between panorama and reconstructed panoramic image. Multiplanar reformation image was obtained after radiography of mandibular dentition. Then, the axial image was examined to obtain cross-sectional images of teeth that ranged from the right second molar to the left second molar before diameter of crown was measured and compared. Based on the cross-section that was radiographed by using the cone beam computed tomography, comparison was made between reconstructed panorama and standard panorama. According to the results of comparison, diameter of crown was measured with a slight difference of around 0.03 mm between the cone beam computed tomography cross-sectional image and the reconstructed image. It was also found that panorama caused image distortion with the large error of around 0.95 mm. Based on these results, it was confirmed that the cone beam computed tomography panorama that was reconstructed in consideration of patient's anatomical structure showed less distortion than the existing panorama. It was also confirmed that depending on distance, there was decrease in reliability of measurement of anatomical structure whose location was different in the existing panoramic image. It is necessary to develop methods and various programs in the future to improve poor image information that is obtained from the cone beam computed tomography and panorama examination.
- 15 September 2014
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 48 (2) , 84-89
Tooth Distortion as a Function of Arch Form in Cone Beam Computed Tomography
The cone beam computed tomography enables conducting measurement of length and area in the space where it is impossible to conduct such measurement compared to panorama. The cone beam computed tomography also enables making three-dimensional diagnosis and establishing treatment plan. In this experiment, the cone beam computed tomography was used to analyze image distortion of anatomical structure whose location was different between panorama and reconstructed panoramic image. Multiplanar reformation image was obtained after radiography of mandibular dentition. Then, the axial image was examined to obtain cross-sectional images of teeth that ranged from the right second molar to the left second molar before diameter of crown was measured and compared. Based on the cross-section that was radiographed by using the cone beam computed tomography, comparison was made between reconstructed panorama and standard panorama. According to the results of comparison, diameter of crown was measured with a slight difference of around 0.03 mm between the cone beam computed tomography cross-sectional image and the reconstructed image. It was also found that panorama caused image distortion with the large error of around 0.95 mm. Based on these results, it was confirmed that the cone beam computed tomography panorama that was reconstructed in consideration of patient's anatomical structure showed less distortion than the existing panorama. It was also confirmed that depending on distance, there was decrease in reliability of measurement of anatomical structure whose location was different in the existing panoramic image. It is necessary to develop methods and various programs in the future to improve poor image information that is obtained from the cone beam computed tomography and panorama examination.
- Open Access
- 1 September 2014
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 7 (3) , 125-130
Children's playground radioactivity concentration of the soil and urethane concentration dose rate measurements compared in Gwangju
- 1 September 2014
- Published by The Research Institute of Advanced Engineering Technology - Chosun University in Journal of Advanced Engineering and Technology
- Vol. 7 (3) , 125-130
Open AccessChildren's playground radioactivity concentration of the soil and urethane concentration dose rate measurements compared in Gwangju
- 25 April 2014
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 47 (9) , 710-715
A Study on Analysis of Labeling Efficiency Depending on Mixing Time in Asan Medical Center Red Blood Cell Labeling Method
The aim of this study was to overcome the shortcomings of technetium-99m red blood cell labeling, such as the requirement of additional time, and to maintain a stable labeling efficiency by reducing the mixing time for technetium-99m red blood cell labeling in the Asan Medical Center red blood cell labeling method developed by this hospital. Thirty patients, who underwent an examination using technetium-99m red blood cell labeling in the nuclear medicine department from April to September 2012, were selected randomly. Blood samples (5 mL per patient) were mixed with acid citrate dextrose, and 1-mL aliquots were taken to make four blood samples. The Asan Medical Center red blood cell labeling method was used for labeling. In this case, the mixing time was set to 5, 10, 15, and 20 min before calculating the efficiency of each labeling. The difference depending on the mixing time was compared. According to the technetium-99m red blood cell labeling efficiency depending on the mixing time in the Asan Medical Center red blood cell labeling method, the efficiency of each labeling was 92 ± 5%, 96 ± 5%, 97 ± 5%, and 98 ± 5% for 5, 10, 15, and 20 min, respectively. Overall, the labeling efficiency was relatively low when the mixing time was 5 min, whereas there was no significant difference in labeling efficiency when the mixing time was longer than 5 min. In conclusion, the Asan Medical Center red blood cell labeling method can provide an environment that is more conducive to the combination of red blood cell with technetium-99m pertechnetate than the previous modified labeling method because the Asan Medical Center red blood cell labeling method removes blood plasma in an additional centrifugation process.
- 25 April 2014
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 47 (9) , 710-715
A Study on Analysis of Labeling Efficiency Depending on Mixing Time in Asan Medical Center Red Blood Cell Labeling Method
The aim of this study was to overcome the shortcomings of technetium-99m red blood cell labeling, such as the requirement of additional time, and to maintain a stable labeling efficiency by reducing the mixing time for technetium-99m red blood cell labeling in the Asan Medical Center red blood cell labeling method developed by this hospital. Thirty patients, who underwent an examination using technetium-99m red blood cell labeling in the nuclear medicine department from April to September 2012, were selected randomly. Blood samples (5 mL per patient) were mixed with acid citrate dextrose, and 1-mL aliquots were taken to make four blood samples. The Asan Medical Center red blood cell labeling method was used for labeling. In this case, the mixing time was set to 5, 10, 15, and 20 min before calculating the efficiency of each labeling. The difference depending on the mixing time was compared. According to the technetium-99m red blood cell labeling efficiency depending on the mixing time in the Asan Medical Center red blood cell labeling method, the efficiency of each labeling was 92 ± 5%, 96 ± 5%, 97 ± 5%, and 98 ± 5% for 5, 10, 15, and 20 min, respectively. Overall, the labeling efficiency was relatively low when the mixing time was 5 min, whereas there was no significant difference in labeling efficiency when the mixing time was longer than 5 min. In conclusion, the Asan Medical Center red blood cell labeling method can provide an environment that is more conducive to the combination of red blood cell with technetium-99m pertechnetate than the previous modified labeling method because the Asan Medical Center red blood cell labeling method removes blood plasma in an additional centrifugation process.
- 1 March 2014
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 65, 174-180
Motion and volume change of tumor tissue depending on patient position in liver cancer treatment with use of tomotherapy
- 1 March 2014
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 65, 174-180
Motion and volume change of tumor tissue depending on patient position in liver cancer treatment with use of tomotherapy