Seismic Retrofit of Non‐Seismically Designed 3D Beam‐Column Joints With Post‐Installed Steel Haunches
Open Access
- 24 July 2025
- journal article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
Abstract
The paper presents experimental results on two‐dimensional and three‐dimensional full‐scale exterior reinforced concrete beam‐column joints subassemblies retrofitted with the Fully Fastened Haunch Retrofit Solution. The specimens were non‐seismically designed with no transverse reinforcement in the joint core, thus making them vulnerable to joint shear failure. Three different beam‐column joint configurations were investigated. The first one was a two‐dimensional subassembly serving as a reference. Two unloaded transverse beams were added in the second specimen, while the third one additionally incorporated a monolithically cast slab. The specimens were subjected to unidirectional, quasi‐static cyclic loads. In this retrofit solution, steel diagonals are post‐installed onto the column and beam to create a new force path around the joint and thereby relocate the plastic hinge away from the joint to the beam. The haunch elements were connected to the column and beam with bonded anchors. The results showcased an upgraded seismic performance of the beam‐column joints in terms of stiffness, strength, and ductility compared to their as‐built counterparts. The results were evaluated in terms of cyclic load‐displacement behaviour, energy dissipation, crack development in concrete, strain development in reinforcing bars and in steel diagonals, as well as qualitative force distribution within the anchor group. The redistribution of forces within the anchor group, an increase in anchorage capacity when the slab was present, as well as the vulnerability of a shear failure in the column due to the slab's participation in flexure constituted the main findings of this study. It was concluded that the performance and efficacy of this retrofit solution strongly depend on the anchorage performance.Keywords
This publication has 20 references indexed in Scilit:
- Experimental and numerical investigations on the influence of transverse beams and slab on the seismic behavior of non‐seismically designed exterior beam‐column jointsEarthquake Engineering & Structural Dynamics, 2024
- Numerical investigations on the influence of transverse beams and slab on the seismic behavior of substandard beam-column jointsEngineering Structures, 2021
- Experimental investigation of 3d RC exterior joint retrofitted with fully-fastened-haunch-retrofit-solutionEngineering Structures, 2021
- Seismic retrofit of exterior RC beam-column joint using diagonal haunchEngineering Structures, 2018
- Seismic retrofit of external concrete beam-column joints reinforced by plain bars using steel angles prestressed by cross tiesEngineering Structures, 2017
- Seismic retrofit of external RC beam–column joints by joint enlargement using prestressed steel anglesEngineering Structures, 2014
- Experimental investigation on reinforced concrete interior beam–column joints rehabilitated by ferrocement jacketsEngineering Structures, 2013
- Local retrofit of exterior RC beam–column joints using thin RC jackets—An experimental studyEarthquake Engineering & Structural Dynamics, 2007
- Development and validation of a metallic haunch seismic retrofit solution for existing under-designed RC frame buildingsEarthquake Engineering & Structural Dynamics, 2006
- Seismic Design of Reinforced Concrete and Masonry Buildings1992