Radiation Exposure during Fluoroscopy-Guided Ozone Chemonucleolysis for Lumbar Disc Herniation
Open Access
- 14 December 2022
- journal article
- review article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (24) , 7424
Abstract
Introduction: Radiation exposure is a frequent drawback of spinal surgery, even if X-ray guidance plays a pivotal role in improving the accuracy and safety of spinal procedures. Consequently, radiation protection is essential to reduce potential negative biological effects. The aim of this study was to evaluate patients’ radiation exposure, the radiation dose emission during fluoroscopy-guided ozone chemonucleolysis (OCN), and the potential role of patient characteristics. Methods: The radiation dose emission reports were retrospectively evaluated in patients who underwent single-level OCN for lumbar disc herniation. A generalized linear model (GLM) with a gamma distribution and log link function was used to assess the association between radiation emission and patients’ characteristics such as age, sex, BMI, level of disc herniation, disc height, and site of disc herniation. Results: Two hundred and forty OCN cases were analyzed. A safe and low level of radiation exposure was registered during OCN. The median fluoroscopy time for OCN was 26.3 (19.4–35.9) seconds, the median radiation emission dose was 19.3 (13.2–27.3) mGy, and he median kerma area product (KAP) was 0.46 (0.33–0.68) mGy ⋅ m2. The resulting KAP values were highly dependent on patient variables. In particular, sex, obesity, and residual disc height < 50% significantly increased the measured KAP, while levels of disc herniations other than L5-S1 reduced the KAP values. Conclusions: The radiation exposure during OCN is low and quite similar to a simple discography. However, patient characteristics are significantly related to radiation exposure and should be carefully evaluated before planning OCN.Keywords
This publication has 41 references indexed in Scilit:
- Fluoroscopic Radiation Exposure in Spinal SurgeryClinical Spine Surgery, 2016
- Duration of Fluoroscopic‐Guided Spine Interventions and Radiation Exposure Is Increased in Overweight PatientsPM&R, 2013
- Type of Interventional Pain Procedure, Body Weight, and Presence of Spinal Pathology are Determinants of the Level of Radiation Exposure for Fluoroscopically Guided Pain ProceduresPain Practice, 2011
- Proinflammatory cytokine expression profile in degenerated and herniated human intervertebral disc tissuesArthritis & Rheumatism, 2010
- Radiation Exposure to Physicians During Interventional Pain ProceduresThe Korean Journal of Pain, 2010
- Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusionJournal of Neurosurgery: Spine, 2008
- Effectiveness of conservative treatments for the lumbosacral radicular syndrome: a systematic reviewEuropean Spine Journal, 2007
- Lumbar disc degeneration: association between osteophytes, end-plate sclerosis and disc space narrowingAnnals of the Rheumatic Diseases, 2007
- What is Intervertebral Disc Degeneration, and What Causes It?Spine, 2006
- Precision measurement of disc height, vertebral height and sagittal plane displacement from lateral radiographic views of the lumbar spineClinical Biomechanics, 1997